Eaton

Eaton Moeller® series STI Control transformer

رقم القطعة: 036392

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Eaton Moeller® series STI Control transformer

المواصفات

Product NameEaton Moeller® series STI Control transformer
Catalog Number036392
Model CodeSTI0,315(230/24)
EAN4015080363927
Product Length/Depth88 mm
Product Height119 mm
Product Width121 mm
Product Weight4.579 kg
CertificationsVDE 0570 Part 2-4 (isolating transformer) VDE 0113, VDE 0100 Part 410 CE UL 506 VDE 0570 Part 2‐6 (safety transformers) IEC/EN 61558-2-2/2-4/2-6 UL5085-1 VDE 0570 Part 2-2 IEC/EN 60204-1, ÖVE-EN 13 UL Category Control No.: XPTQ2, XPTQ8 UL Recognized UL report applies to both US and Canada CSA-C22.2 No. 66.1-06 IEC/EN 61558-2-2 Certified by UL for use in Canada CSA-C22.2 No. 66.2-06 UL File No.: E167225 CSA-C22.2 No. 66 UL 5085-2
Source URLhttps://www.eaton.com/gb/en-gb/skuPage.036392.html
Catalog NotesElectrical characteristics: all details for no-load loss, short-circuit loss (copper losses), short-circuit voltage and efficiency values relate to a temperature of 20 °C
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0 W
Rated operational current for specified heat dissipation (In)0 A
Static heat dissipation, non-current-dependent Pvs28 W

منتجات مشابهة