Eaton Moeller series xPole - PKP62/M2 RCBO - residual-current circuit breaker with overcurrent prote
رقم القطعة: 111622
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.


رقم القطعة: 111622
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
Eaton Moeller series xPole - PKP62/M2 RCBO - residual-current circuit breaker with overcurrent protection
| Ambient operating temperature - max | 40 °C |
|---|---|
| Ambient operating temperature - min | -25 °C |
| Product Name | Eaton Moeller series xPole - PKP62/M2 RCBO - residual-current circuit breaker with overcurrent protection |
| Catalog Number | 111622 |
| Model Code | PKPM2-6/2/C/003 |
| EAN | 4015081111824 |
| Product Length/Depth | 86 mm |
| Product Height | 75 mm |
| Product Width | 37 mm |
| Product Weight | 0.25 kg |
| Compliances | CE Marked RoHS conform |
| Certifications | CE |
| Source URL | https://www.eaton.com/gb/en-gb/skuPage.111622.html |
| Type | RCBO |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Degree of protection | IP20 |
| Built-in depth | 70 mm |
| Width in number of modular spacings | 2 |
| Mounting method | DIN rail |
| Number of poles | Two-pole |
| Rated operational voltage (Ue) - max | 230 V |
| Voltage rating | 230 V |
| Rated operational current for specified heat dissipation (In) | 6 A |
| Frequency rating | 50 Hz |
| Pollution degree | 2 |
| Rated insulation voltage (Ui) | 250 V |
| Overvoltage category | III |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Voltage type | AC |
| Connectable conductor cross section (multi-wired) - max | 25 mm² |
| Connectable conductor cross section (multi-wired) - min | 1 mm² |
| Connectable conductor cross section (solid-core) - max | 25 mm² |
| Connectable conductor cross section (solid-core) - min | 1 mm² |
| Heat dissipation per pole, current-dependent | 0 W |
| Equipment heat dissipation, current-dependent | 2.2 W |
| Application | Switchgear for residential and commercial applications |
| Static heat dissipation, non-current-dependent | 0 W |
| Heat dissipation capacity | 0 W |
| Current limiting class | 3 |
| Surge current capacity | 0.25 kA |
| Operating ambient temperature - max | 40 °C |
| Operating ambient temperature - min | -25 °C |
| Product application | Switchgear for industrial and advanced commercial applications |
| Product range | PKPM2 |
| Rated current | 6 A |
| Rated switching capacity (IEC/EN 61009) | 10 kA |
| Tripping characteristic | C |
| Rated short-circuit breaking capacity (EN 60947-2) | 0 kA |
| Fault current rating | 0.03 A |
| Number of poles (protected) | 2 |
| Number of poles (total) | 2 |
| Rated switching capacity | 10 kA |
| Basic function | Combined RCD/MCB devices |
| Tripping | Non-delayed |
| Impulse withstand current | Partly surge-proof, 250 A |
| Leakage current type | AC |
| Release characteristic | C |
| Sensitivity type | Type AC, AC current sensitive. |
| Rated short-circuit breaking capacity (EN 61009) | 10 kA |
| Rated short-circuit breaking capacity (EN 61009-1) | 10 kA |
| Disconnection characteristic | Undelayed |