Eaton Moeller series xEffect - FAZ-NA-DC MCB

المواصفات

Ambient operating temperature - max75 °C
Ambient operating temperature - min-25 °C
Special featuresAmbient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity
Product NameEaton Moeller series xEffect - FAZ-NA-DC MCB
Catalog Number137239
Model CodeFAZ-C2/2-NA-DC
EAN4015081340293
Product Length/Depth105 mm
Product Height75.5 mm
Product Width35.4 mm
Product Weight0.247 kg
CompliancesRoHS conform
CertificationsIEC 60947-2 UL 489, CSA C22.2 No. 5 EN45545-2 IEC 61373
Source URLhttps://www.eaton.com/gb/en-gb/skuPage.137239.html
Used withFAZ-DC Miniature circuit breaker
FeaturesAdditional equipment possible
TypeFAZ-DCMiniature circuit breaker
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Degree of protectionIP20
Built-in depth70.5 mm
Width in number of modular spacings2
Number of polesTwo-pole
Amperage Rating2 A
Rated operational voltage (Ue) - max250 V
Rated operational current for specified heat dissipation (In)2 A
Voltage rating at DC440 V DC
Pollution degree2
Rated insulation voltage (Ui)440 V
Overvoltage categoryIII
Rated impulse withstand voltage (Uimp)4 kV
Voltage typeDC
Connectable conductor cross section (multi-wired) - max25 mm²
Connectable conductor cross section (multi-wired) - min1 mm²
Connectable conductor cross section (solid-core) - max25 mm²
Connectable conductor cross section (solid-core) - min1 mm²
Heat dissipation per pole, current-dependent0 W
Equipment heat dissipation, current-dependent2.8 W
ApplicationSwitchgear for export to North America (UL-listed)
Static heat dissipation, non-current-dependent0 W
Heat dissipation capacity0 W
Current limiting class3
Tripping characteristicC
Number of poles (protected)2
Number of poles (total)2
Release characteristicC
Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 230 V10 kA
Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 400 V10 kA
Rated switching capacity (IEC/EN 60947-2)10 kA
Power loss2.8 W