Eaton Moeller series xEffect - FBSmV RCCB add-on unit
| Ambient operating temperature - max | 40 °C |
|---|---|
| Ambient operating temperature - min | -25 °C |
| Climatic proofing | 25-55 °C / 90-95% relative humidity according to IEC 60068-2 |
| Special features | Ambient temperature hint: Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °C |
| Product Name | Eaton Moeller series xEffect - FBSmV RCCB add-on unit |
| Catalog Number | 170145 |
| Model Code | FBSMV-63/2/1-S |
| EAN | 4015081666454 |
| Product Length/Depth | 90 mm |
| Product Height | 75 mm |
| Product Width | 70 mm |
| Product Weight | 0.215 kg |
| Compliances | RoHS conform |
| Certifications | EN45545-2 IEC 61373 IEC/EN 61009 |
| Source URL | https://www.eaton.com/gb/en-gb/skuPage.170145.html |
| Used with | Type S FBSmV Add-on residual current protection unit |
| Features | Additional equipment possible Add-on residual current protection unit Selective protection |
| Type | Add-on residual current protection unitFBSmVType S |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Degree of protection | IP20 IP20, IP40 with suitable enclosure |
| Built-in depth | 70 mm |
| Width in number of modular spacings | 4 |
| Mounting method | Permanent screw connection with FAZ DIN rail |
| Fitted with: | Interlocking device |
| Number of poles | Two-pole |
| Amperage Rating | 63 A |
| Rated operational voltage (Ue) - max | 240 V |
| Rated operational current for specified heat dissipation (In) | 63 A |
| Frequency rating | 50 Hz |
| Pollution degree | 2 |
| Rated insulation voltage (Ui) | 440 V |
| Frame | 45 mm |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Connectable conductor cross section (multi-wired) - max | 35 mm² |
| Connectable conductor cross section (multi-wired) - min | 0.75 mm² |
| Connectable conductor cross section (solid-core) - max | 35 mm² |
| Connectable conductor cross section (solid-core) - min | 0.75 mm² |
| Voltage rating - max | 415 V |
| Heat dissipation per pole, current-dependent | 0 W |
| Equipment heat dissipation, current-dependent | 17 W |
| Application | Switchgear for industrial and advanced commercial applicationsxEffect - Switchgear for industrial and advanced commercial applications |
| Static heat dissipation, non-current-dependent | 0 W |
| Heat dissipation capacity | 0 W |
| Terminal protection | Finger and hand touch safe, DGUV VS3, EN 50274 |
| Voltage rating - min | 240 V |
| Surge current capacity | 5 kA |
| Fault current rating | 1000 mA |
| Impulse withstand current | Surge-proof 5 kA |
| Leakage current type | AC |
| Sensitivity type | AC current sensitive |
| Rated short-time withstand current (Icw) | 0 kA 10 kA |
| Built-in width (number of units) | 70 mm (2 SU) |
| Busbar material thickness | 0.8 mm - 2 mm |
| Terminals (top and bottom) | Lift terminals |
| Permitted storage and transport temperature - max | 60 °C |
| Permitted storage and transport temperature - min | -35 °C |
| Rated fault current - max | 1 A |
| Rated fault current - min | 1 A |
| Tripping time | Selective switch off 40 ms delayed - selective switch off |
| Rated short-circuit strength | Same as connected FAZ up to max. 10 kA |
| Power loss | 4.4 W |