Eaton J-Range enclosed switch-disconnector
رقم القطعة: 199555
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.


رقم القطعة: 199555
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
Eaton J-Range enclosed switch-disconnector
| Ambient operating temperature (enclosed) - max | 40 °C |
|---|---|
| Ambient operating temperature (enclosed) - min | -25 °C |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78 |
| Functions | STOP function Interlockable |
| Number of auxiliary contacts (change-over contacts) | 0 |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Product Name | Eaton J-Range enclosed switch-disconnector |
| Catalog Number | 199555 |
| Model Code | J32/B/N |
| EAN | 5027590552066 |
| Product Length/Depth | 115 mm |
| Product Height | 180 mm |
| Product Width | 100 mm |
| Product Weight | 0.447 kg |
| Certifications | VDE 0660 IEC/EN 60947-3 IEC/EN 60204 IEC/EN 60947 |
| Source URL | https://www.eaton.com/gb/en-gb/skuPage.199555.html |
| Catalog Notes | Rated Short-time Withstand Current (Icw) for a time of 1 second |
| Actuator type | Door coupling rotary drive |
| Actuator color | Black |
| Suitable for | Ground mounting |
| Features | Version as maintenance-/service switch Version as main switch |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | UV resistance only in connection with protective shield. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Degree of protection | NEMA 12 |
| Mounting method | Surface mounting |
| Fitted with: | Black rotary handle and locking ring Push-through cable entry diaphragm Assembly sheet screen |
| Mounting position | As required |
| Shock resistance | 15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms |
| Number of poles | Three-pole |
| Rated uninterrupted current (Iu) | 32 A |
| Product category | Main switch |
| Pollution degree | 3 |
| Electrical connection type of main circuit | Screw connection |
| Overvoltage category | III |
| Operating frequency | 1200 Operations/h |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Rated impulse withstand voltage (Uimp) | 6000 V AC |
| Terminal capacity | 2 x (1 - 4) mm², flexible with ferrules to DIN 46228 2 x (1.5 - 6) mm², solid or stranded 1 x (1.5 - 10) mm², solid or stranded 1 x (1 - 4) mm², flexible with ferrules to DIN 46228 |
| Degree of protection (front side) | IP65 |
| Lifespan, mechanical | 300,000 Operations |
| Housing material | Plastic |
| Rated conditional short-circuit current (Iq) | 80 kA |
| Short-circuit protection rating | 50 A gG/gL, Fuse, Contacts |
| Rated short-time withstand current (Icw) | 0.64 kA 640 A, Contacts, 1 second |
| Rated operational power at AC-23A, 400 V, 50 Hz | 13 kW |
| Tightening torque | 1.6 Nm, Screw terminals |
| Locking facility | Lockable in the 0 (Off) position |
| Rated permanent current at AC-21, 400 V | 32 A |
| Device construction | Complete device in housing |
| Number of switches | 1 |
| Screw size | M4, Terminal screw |
| Safety parameter (EN ISO 13849-1) | B10d values as per EN ISO 13849-1, table C.1 |
| Rated operating voltage (Ue) - max | 690 V |
| Rated operating voltage (Ue) - min | 690 V |
| Uninterrupted current | Rated uninterrupted current Iu is specified for max. cross-section. |
| Voltage per contact pair in series | 60 V |
| Safe isolation | 440 V AC, Between the contacts, According to EN 61140 |
| Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3) | 260 A |
| Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3) | 300 A |
| Rated breaking capacity at 500 V (cos phi to IEC 60947-3) | 290 A |
| Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3) | 250 A |
| Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3) | 320 A |
| Rated operational current (Ie) at AC-21, 400 V, 415 V | 32 A |
| Rated operational current (Ie) at AC-21, 440 V | 32 A |
| Rated operational current (Ie) at AC-21, 500 V | 32 A |
| Rated operational current (Ie) at AC-21, 690 V | 32 A |
| Rated operational current (Ie) at AC-22, 380 V, 400 V, 415 V | 32 A |
| Rated operational current (Ie) at AC-22, 500 V | 32 A |
| Rated operational current (Ie) at AC-22, 690 V | 32 A |
| Rated operational current (Ie) at DC-1, load-break switches l/r = 1 ms | 32 A |

Eaton