ABB

EN40-40N-06

رقم القطعة: 1SAE342111R0640

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

كونتاكتور تركيب EN40-40N-06، رباعي الأقطاب

المواصفات

Extended Product TypeEN40-40N-06
Product ID1SAE342111R0640
EAN4013614518836
Catalog DescriptionEN40-40N-06 Installation Contactor (NO) 40 A - 4 NO - 0 NC - 230 V - Control Circuit 400 Hz
Long DescriptionThe EN40..N installation contactors are used to control single and three-phase loads up to 40 A and can be operated by AC or DC and/or manually. These contactors are made for use in household applications as well as in industrial environments. The following benefits are provided: Hum-free operation, low power consumption, integrated overvoltage protection and manual override. Various contact combinations and accessories are available. Manual operation is available in 3 states: "On", "Off", "Auto"
Display NameEN40-40N-06
Country of OriginIndia
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85365080
EPLAN Data9AAC404719_EPLAN
Data Sheet, Technical Information2CDC103051C0201
Instructions and Manuals2CDC103043M6801
CAD Dimensional Drawing2CDC001079B0201
Product Net Width54 mm
Product Net Depth / Length65 mm
Product Net Height85 mm
Product Net Weight0.41 kg
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles4P
StandardsIEC/EN 60947-1
Rated Operational VoltageMain Circuit 220 V DC
Rated Frequency (f)Control Circuit 400 Hz
Rated Operational Current AC-1 (I<sub>e</sub>)(NO) 40 A
Rated Operational Current AC-3 (I<sub>e</sub>)(230 V) Single Phase, NO 22 A
Rated Operational Current AC-7a (I<sub>e</sub>)(NO) 40 A
Rated Operational Current AC-7b (I<sub>e</sub>)(230 V) Single Phase, NO 22 A
Rated Operational Power AC-1 (P<sub>e</sub>)(230 V) Single Phase, NO 9.2 kW
Rated Operational Power AC-3 (P<sub>e</sub>)(230 V) Single Phase, NO 3.7 kW
Rated Operational Power AC-7a (P<sub>e</sub>)(230 V) Single Phase, NO 9.2 kW
Rated Operational Power AC-7b (P<sub>e</sub>)(230 V) Single Phase, NO 3.7 kW
Rated Breaking Capacity AC-38 x Ie / AC-3
Rated Making Capacity AC-310 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
Rated Insulation Voltage (U<sub>i</sub>)500 V
Rated Impulse Withstand Voltage (U<sub>imp</sub>)4 kV
Electrical DurabilityAC-1 (NO) 150000 cycle
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Mechanical DurabilityNr. Operations 1000000 cycle
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (U<sub>c</sub>)230 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 4.5 V·A
Power Lossat Rated Operating Conditions AC-1 per Pole 3 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main CircuitFlexible with Ferrule 1x 1.5 ... 16 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 7 mm
Degree of ProtectionIP20
Recommended Screw DriverControl Circuit Pozidriv 1
Tightening TorqueControl Circuit 0.9 N·m
Terminal TypeScrew Terminals
Width in Number of Modular Spacings3
Product NameInstallation Contactor
Ambient Air TemperatureOperation -25 ... +55 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Pollution Degree3
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Consumer
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
EcoSolutions Profile1SFC100125C0336
End Of Life Disassembling Instructions1SBC100156C0267
Environmental Product Declaration - EPD1SAC200433H0001
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 94.1 %
A2L Certificate – IEC1SAA920000-4601
CB Certificate1SAA920005-2001
CCC Certificate2024010304659840
Declaration of Conformity - CE1SAD101100-3301
Declaration of Conformity - UKCA1SAD201100-3301
Package Level 1 Unitsbox 1 piece
Package Level 1 Width92 mm
Package Level 1 Depth / Length57 mm
Package Level 1 Height69.5 mm
Package Level 1 Gross Weight0.41 kg
Package Level 1 EAN4013614525148
Package Level 2 Units32 piece
Package Level 2 Width280 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Height210 mm
Package Level 2 Gross Weight13.5 kg
Package Level 2 EAN4013614539541
Object Classification CodeQ
ETIM 7EC001653 - Installation contactor for distribution board
ETIM 8EC001653 - Installation contactor for distribution board
ETIM 9EC001653 - Installation contactor for distribution board
eClassV11.0 : 27142308
UNSPSC39121529
IDEA Granular Category Code (IGCC)4759 >> Installation contactor for distribution board
E-Number (Finland)3707811
E-Number (Norway)4190273
Source URLhttps://new.abb.com/products/1SAE342111R0640/en40-40n-06
ABB Taxonomy PathLow Voltage Products and Systems > Modular DIN Rail Products > Command and Signalling Devices > Installation Contactors
ABB Classification IDs9AAC910006, 9AAF617929, 9AAC100111, 9AAF617940, 9AAC404719
NF Certificate1SAA920001-1202