ABB

MO165-32

رقم القطعة: 1SAM461000R1014

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

بادئ تشغيل محرك يدوي MO165-32، ثلاثي الأقطاب

المواصفات

Extended Product TypeMO165-32
Product ID1SAM461000R1014
EAN4013614486159
Catalog DescriptionMO165-32 Manual Motor Starter Magnetic Only 32 A
Long DescriptionThe MO165 manual motor starter magnetic only is a compact and powerful range for motor protection up to 45 kW (400 V) in width of 55 mm. The devices are used to manually switch on and off loads/motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter offers a rated service short-circuit breaking capacity up to 100 kA at 400 V AC. A combination together with overload relays or motor controllers allows the protection of motors. Further features are the built-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starters magnetic only are suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars and power in-feed blocks are available as accessory.
Display NameMO165-32
Country of OriginIndia
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85362010
Data Sheet, Technical Information2CDC131084D0201
Instructions and Manuals2CDC131082M6801
CAD Dimensional Drawing2CDC001079B0201
Product Net Width55 mm
Product Net Depth / Length122.1 mm
Product Net Height142.65 mm
Product Net Weight0.97 kg
Number of Poles3P
StandardsCSA 22.2 No. 14
Rated Operational VoltageMain Circuit 690 V AC
Rated Frequency (f)Main Circuit 50 Hz
Rated Operational Current AC-3 (I<sub>e</sub>)32 A
Rated Operational Power AC-3 (P<sub>e</sub>)(400 V) Three Phase 15 kW
Rated Insulation Voltage (U<sub>i</sub>)1000 V
Rated Impulse Withstand Voltage (U<sub>imp</sub>)Main Circuit 8 kV
Electrical Durability25000 cycle
Mechanical DurabilityNr. Operations 50000 cycle
Power Loss4.4 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 35 mm²
Wire Stripping LengthMain Circuit 16 mm
Degree of ProtectionHousing IP20
Recommended Screw DriverPozidriv 2
Tightening TorqueMain Circuit 4 N·m
Terminal TypeScrew Terminals
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
General Use Rating UL/CSA(600 V AC) 32 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 7.5 Hp
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-0 AWG
Tightening Torque UL/CSAMain Circuit 35 in·lb
Full Load Amps Motor Use(200 V AC) Three Phase 25.3 A
Ambient Air TemperatureOperation -25 ... +60 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Pollution Degree3
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SAA963005-4502
RoHS Declaration1SAA963006-4501
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006539
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
EcoSolutions Profile1SFC100125C0353
End Of Life Disassembling Instructions1SAC200284H0001
Environmental Product Declaration - EPD1SAC200253H0001
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 93.1 %
ABS Certificate1SAA963002-0101
CB Certificate1SAA918002-2002
CCC Certificate2024010307654703
Declaration of Conformity - CE1SAD101100-3409
Declaration of Conformity - UKCA1SAD201100-3409
UL CertificateE137861-20150206
Package Level 1 Unitsbox 1 piece
Package Level 1 Width64 mm
Package Level 1 Depth / Length177 mm
Package Level 1 Height140 mm
Package Level 1 Gross Weight1.1 kg
Package Level 1 EAN4013614486159
Package Level 2 Unitscarton 12 piece
Package Level 2 Width330 mm
Package Level 2 Depth / Length400 mm
Package Level 2 Height320 mm
Package Level 2 Gross Weight13 kg
Package Level 2 EAN4013614504013
Object Classification CodeF
ETIM 9EC000074 - Motor protection circuit-breaker
eClassV11.0 : 27370401
UNSPSC39121521
IDEA Granular Category Code (IGCC)4731 >> Manual Starters
E-Number (Finland)3707294
E-Number (Norway)4364143
E-Number (Sweden)3110141
Source URLhttps://new.abb.com/products/1SAM461000R1014/mo165-32
ABB Taxonomy PathLow Voltage Products and Systems > Control Products > Manual Motor Starters > Manual Motor Starters
ABB Classification IDs9AAC910006, 9AAC166172, 9AAC100130, 9AAC179508, 9AAC179507
Conventional Free-air Thermal Current (I<sub>th</sub>)Main Circuit 32 A
Resistance to VibrationsMounted on Mounting Plate: 5g 3 ... 150 Hz
BV Certificate1SAA963002-0201
CQC CertificateCQC2015010307760141
Declaration of Conformity - CCC2020980307003042
ETIM 10EC000074 - Motor protection circuit-breaker
Mounting Position1 ... 6
DNV GL Certificate1SAA963002-0301
EAC Certificate1SAA963000-2701
LR Certificate1SAA918001-0501
RemarksFor overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Dimension Diagram1SAM400402F0001
Contact Position IndicationON / OFF / TRIP
Instructions and Manuals (Part 2)2CDC131060M0202
Time-Current Characteristic Curve1SAM400515F0001
I²t Characteristic1SAM400506F0001
Cut-off Current Characteristic1SAM400507F0001
Rated Service Short-Circuit Breaking Capacity (I<sub>cs</sub>)(230 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (I<sub>cu</sub>)(230 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (I<sub>i</sub>)480 A
Setting RangeNone
Rated Operational Power AC-3e (P<sub>e</sub>)(400 V) Three Phase 15 kW
Rated Operational Current (I<sub>e</sub>)32 A
Rated Operational Current AC-3e (I<sub>e</sub>)32 A
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Short-Circuit Current Rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Locked Rotor Amps(200 V AC) Three Phase 146 A
Ambient Air Temperature CompensationNo
RMRS Certificate1SAA918000-0704
Operating Frequency (f<sub>sw</sub>)0 ... 415 Hz
Rated Operational Current DC-5 (I<sub>e</sub>)32 A
IECEx Certificate1SAA918000-4001