ريليه حماية حرارية من التحميل الزائد TA200DU-200، ثلاثي الأقطاب
| Extended Product Type | TA200DU-200 |
|---|---|
| Product ID | 1SAZ421201R1006 |
| EAN | 4013614286063 |
| Catalog Description | TA200DU-200 Thermal Overload Relay 150 ... 200 A |
| Long Description | The TA200DU-200 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory. |
| Display Name | TA200DU-200 |
| Country of Origin | India |
| Made To Order | No |
| Warranty Return | Product under warranty must be returned |
| Product Sales Status | Active |
| Quote Only | No |
| Stocked At Warehouses | INABB015EXPU |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 2CDC106028M6802 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Product Net Width | 104 mm |
| Product Net Depth / Length | 126 mm |
| Product Net Height | 151 mm |
| Product Net Weight | 0.785 kg |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1 |
| Rated Operational Voltage | Auxiliary Circuit 440 V DC |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz |
| Rated Insulation Voltage (U<sub>i</sub>) | 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Power Loss | at Rated Operating Conditions per Pole 4.3 ... 7.7 W |
| Connecting Capacity Main Circuit | Hole Diameter > 10 mm² |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Degree of Protection | Housing IP20 |
| Recommended Screw Driver | Auxiliary Circuit Pozidriv 1 |
| Tightening Torque | Auxiliary Circuit 1 ... 1.3 N·m |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1x 4-0000 AWG |
| Tightening Torque UL/CSA | Auxiliary Circuit 12 in·lb |
| Ambient Air Temperature | Operation -25 ... +55 °C |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 12g |
| Pollution Degree | 3 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| EcoSolutions Profile | 1SFC100125C0355 |
| End Of Life Disassembling Instructions | 1SAC200335H0001 |
| Environmental Product Declaration - EPD | 1SAC200275H0001 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 62.6 % |
| ABS Certificate | 1SAA941000-0102 |
| CB Certificate | 1SAA941004-2003 |
| CCC Certificate | 2024010304659820 |
| Declaration of Conformity - CE | 1SAD101100-3509 |
| Declaration of Conformity - UKCA | 1SAD201100-3509 |
| DNV Certificate | 1SAA941000-0304 |
| UL Certificate | E48139-19910930 |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 165 mm |
| Package Level 1 Depth / Length | 151 mm |
| Package Level 1 Height | 133 mm |
| Package Level 1 Gross Weight | 1.035 kg |
| Package Level 1 EAN | 4013614286063 |
| Package Level 2 Units | 4 piece |
| Package Level 2 Width | 280 mm |
| Package Level 2 Depth / Length | 395 mm |
| Package Level 2 Height | 210 mm |
| Package Level 2 Gross Weight | 8.786 kg |
| Package Level 2 EAN | 4013614494284 |
| Object Classification Code | F |
| ETIM 9 | EC000106 - Thermal overload relay |
| eClass | V11.0 : 27371501 |
| UNSPSC | 39122330 |
| IDEA Granular Category Code (IGCC) | 5366 >> Thermal overload relay |
| E-Number (Finland) | 3709362 |
| E-Number (Sweden) | 3228710 |
| Source URL | https://new.abb.com/products/1SAZ421201R1006/ta200du-200 |
| ABB Taxonomy Path | Low Voltage Products and Systems > Control Products > Contactors > Thermal Overload Relays |
| ABB Classification IDs | 9AAC910006, 9AAC100113, 9AAC204945 |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | Auxiliary Circuit NC 10 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (120 V) NC 3 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (125 V) NC 0.25 A |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Suitable For | A145 |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-14 AWG |
| Contact Rating UL/CSA | (NO:) B600 |
| BV Certificate | 1SAA941000-0201 |
| CQC Certificate | CQC2016010309922936 |
| Declaration of Conformity - CCC | 2020980304001321 |
| ETIM 10 | EC000106 - Thermal overload relay |
| Mounting Position | 1 ... 6 |
| DNV GL Certificate | 1SAA941000-0304 |
| EAC Certificate | 1SAA941002-2702 |
| LR Certificate | 1SAA941000-0504 |
| GL Certificate | 1SAA941000-0304 |
| Dimension Diagram | 1SAZ400401F0001 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| Time-Current Characteristic Curve | 1SAZ400502F0006 |
| Setting Range | 150 ... 200 A |
| Rated Operational Current (I<sub>e</sub>) | 200 A |
| Ambient Air Temperature Compensation | Yes |
| RMRS Certificate | 1SAA941000-0704 |
| Number of Protected Poles | 3 |
| Environmental Information | 1SAC200056H0009 |