ريليه حماية حرارية من التحميل الزائد T16-4.2، ثلاثي الأقطاب
| Extended Product Type | T16-4.2 |
|---|---|
| Product ID | 1SAZ711201R1035 |
| EAN | 4013614397929 |
| Catalog Description | T16-4.2 Thermal Overload Relay 3.1 ... 4.2 A |
| Long Description | The T16-4.2 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The overload relays are connected directly to the mini contactors or block contactors. Single mounting kits are available as accessory. |
| Display Name | T16-4.2 |
| Country of Origin | India |
| Made To Order | No |
| Warranty Return | Product under warranty must be returned |
| Product Sales Status | Active |
| Quote Only | No |
| Stocked At Warehouses | INABB015EXPU |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Data Sheet, Technical Information | 2CDC106020D0201 |
| Instructions and Manuals | 2CDC106019M6802 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 53.5 mm |
| Product Net Height | 76.7 mm |
| Product Net Weight | 0.1 kg |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1 |
| Rated Operational Voltage | Auxiliary Circuit 600 V AC/DC |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz |
| Rated Insulation Voltage (U<sub>i</sub>) | 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Power Loss | at Rated Operating Conditions per Pole 1.1 ... 2.0 W |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 4 mm² |
| Wire Stripping Length | Auxiliary Circuit 9 mm |
| Degree of Protection | IP20 |
| Recommended Screw Driver | Main Circuit Pozidriv 2 |
| Tightening Torque | Auxiliary Circuit 1 ... 1.2 N·m |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 18-12 AWG |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 ... 11 in·lb |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 22g |
| Pollution Degree | 3 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| A2L Certificate – IEC | 1SAA941000-4601 |
| ABS Certificate | 1SAA941001-0102 |
| CB Certificate | 1SAA941008-2001 |
| CCC Certificate | 2024010304658957 |
| Declaration of Conformity - CE | 1SAD101100-3502 |
| Declaration of Conformity - UKCA | 1SAD201100-3502 |
| RINA Certificate | 1SAA941000-0802 |
| UL Certificate | E48139-20090126 |
| Package Level 1 Units | carton 1 piece |
| Package Level 1 Width | 48 mm |
| Package Level 1 Depth / Length | 82 mm |
| Package Level 1 Height | 63 mm |
| Package Level 1 Gross Weight | 0.112 kg |
| Package Level 1 EAN | 4013614397929 |
| Package Level 2 Units | 40 piece |
| Package Level 2 Width | 280 mm |
| Package Level 2 Depth / Length | 395 mm |
| Package Level 2 Height | 210 mm |
| Package Level 2 Gross Weight | 8.45 kg |
| Package Level 2 EAN | 4013614440632 |
| Object Classification Code | F |
| ETIM 9 | EC000106 - Thermal overload relay |
| eClass | V11.0 : 27371501 |
| UNSPSC | 39122330 |
| IDEA Granular Category Code (IGCC) | 5366 >> Thermal overload relay |
| E-Number (Finland) | 3706145 |
| E-Number (Norway) | 4117162 |
| E-Number (Sweden) | 3212066 |
| Source URL | https://new.abb.com/products/1SAZ711201R1035/t16-4-2 |
| ABB Taxonomy Path | Low Voltage Products and Systems > Control Products > Contactors > Thermal Overload Relays |
| ABB Classification IDs | 9AAC910006, 9AAC100113, 9AAC157704 |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | Auxiliary Circuit NC 6 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (120 V) NC 3 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (125 V) NC 0.55 A |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Suitable For | B6 |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-12 AWG |
| Contact Rating UL/CSA | (NC:) B600 |
| Resistance to Vibrations | 3g 3 ... 150 Hz |
| BV Certificate | 1SAA941001-0203 |
| CQC Certificate | CQC2011010309459316 |
| Declaration of Conformity - CCC | 2020980304001787 |
| ETIM 10 | EC000106 - Thermal overload relay |
| DNV GL Certificate | 1SAA941001-0302 |
| EAC Certificate | 1SAA941002-2702 |
| LR Certificate | 1SAA941001-0502 |
| GL Certificate | 1SAA941007-0401 |
| Dimension Diagram | 1SAZ700404F0001 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| Time-Current Characteristic Curve | 1SAZ700505F0013 |
| Setting Range | 3.1 ... 4.2 A |
| Rated Operational Current (I<sub>e</sub>) | 4.2 A |
| Ambient Air Temperature Compensation | Yes |
| RMRS Certificate | 1SAA941000-0704 |
| Number of Protected Poles | 3 |
| Environmental Information | 1SAC200055H0009 |