Extended Product TypeDS201 M C16 APR100
Product ID2CSR275480R2164
EAN8012542581918
Catalog DescriptionResidual Current Circuit Breaker with Overcurrent Protection DS201 M - 1P+N - 100 mA - 16 A - C - Type A APR
Long DescriptionThe DS201 series is a 1P+N RCBO in two-modules width for the protection of end user single-phase circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating and direct pulsating earth fault currents; protection against indirect contacts and additional protection against direct contacts. The APR type provides an optimal trade-off between safety and continuity of service, thanks to the resistance to unwanted trippings, offering good protection and isolation of resistive and inductive loads.
Display NameDS201 M C16 APR100
EPLAN Data9AAC554444_EPLAN
Data Sheet, Technical Information9AKK107492A6187
Instructions and Manuals9AKK107492A6006
Product Net Width35 mm
Product Net Depth / Length69 mm
Product Net Height85 mm
Product Net Weight200 g
Number of Poles1P+N
StandardsIEC/EN 61009-1, IEC/EN 61009-2-1
Rated Operational Voltageacc. to IEC 60898-1 240 V
Rated Frequency (f)50 / 60 Hz
Rated Insulation Voltage (U<sub>i</sub>)acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (U<sub>imp</sub>)4 kV
Power LossAverage per Pole 2.3 W
Wire Stripping Length12 mm
Degree of ProtectionIP20
Tightening Torque2.8 N·m
Terminal TypeScrew Terminals
Width in Number of Modular Spacings2
Ambient Air TemperatureOperation -25 … 55 °C
Resistance to Shock acc. to IEC 60068-2-2725g 2 shocks 13 ms
Pollution Degree2
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
REACH Declaration9AKK108467A9482
RoHS Declaration9AKK106713A5588
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Consumer
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
EcoSolutions Profile9AKK108470A2163
End Of Life Disassembling Instructions9AKK108469A2268
Environmental Product Declaration - EPD9AKK108468A5756
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 75.20 %
ABS Certificate9AKK107991A2823
CB Certificate9AKK107492A6064
CCC Certificate9AKK107492A6069
Declaration of Conformity - CE9AKK106713A5588
Package Level 1 Unitsbox 1 piece
Package Level 1 Gross Weight225 g
Object Classification CodeF
ETIM 9EC000905 - Earth leakage circuit breaker
eClassV11.0 : 27142207
UNSPSC39121601
IDEA Granular Category Code (IGCC)4875 >> Residual current circuit breaker (RCCB)
E-Number (Norway)1683129
E-Number (Sweden)2100802
Source URLhttps://new.abb.com/products/2CSR275480R2164/ds201-m-c16-apr100
ABB Taxonomy PathLow Voltage Products and Systems > Modular DIN Rail Products > Residual Current Devices RCDs > Residual Current Circuit Breakers with Overcurrent Protection RCBO
ABB Classification IDs9AAC910006, 9AAC100504, 9AAC554444
SCIPebc9dbd4-d627-44ca-81d2-69f973ab2615 Italy
Resistance to Vibrations20 Cycles with Load 0.8 In: 1g or 0.1mm 5...150...5 Hz
ETIM 10EC000905 - Earth leakage circuit breaker
Mounting PositionAny
DNV GL Certificate9AKK107680A3457
EAC Certificate9AKK107492A6071
Contact Position IndicationRed ON / Green OFF
Rated Service Short-Circuit Breaking Capacity (I<sub>cs</sub>)11.2 kA
Rated Ultimate Short-Circuit Breaking Capacity (I<sub>cu</sub>)15 kA
RMRS Certificate9AKK107680A3454
Number of Protected Poles1
Environmental Information2CSC422002K2701
Rated Current (I<sub>n</sub>)16 A
Mounting TypeDIN-Rail
Rated Conditional Short-Circuit Current (I<sub>nc</sub>)15 kA
VDE Certificate9AKK107492A6093
Extended Product LifetimeProduct Durability
Connecting CapacityBusbar 10 ... 10 mm²
REACH InformationTrue - contains substances > 0.1 mass percentage
RoHS Date20211115
REACH Date20240429
Accessory TypeAuxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Accessories AvailableYes
Built-In Depth (<em>t<sub>2</sub></em>)69 mm
Overvoltage CategoryIII
Electrical Endurance10000 cycle
Mechanical Endurance20000 cycle
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Actuator MaterialInsulation Group II, Black, Sealable
Actuator TypeToggle
Environmental Conditions28 cycles
Sustainable Material Content in Packaging (wt. %)Recycled Cardboard - 98 %
Type of Residual CurrentType A APR
Dielectric Test Voltage2 kV
Rated Residual Current100 mA
Input Voltage TypeAC
Number of Batteries0
Carbon Footprint (Full Lifecycle)37.296512 kg CO₂ eq
Rated Short-Circuit Capacity10 kA
Energy Limiting Class3
Tripping CharacteristicC
Power Supply ConnectionArbitrary
Reference Ambient Air Temperature30 °C
Test Voltage (Ut)Minimum 110 V
Rated Residual Breaking Capacity (I&Delta;m)EN 61009-1 6000 A
Number of Modular Spacings per DIN Rail2
Fault IndicationBlue Flag on Toggle
Operating Characteristic10ms Delay (High Immunity)
Position of Neutral TerminalsRight
Housing TypeInsulation group I - II, RAL 7035
Maximum Surge Current3 kA
Surge Immunity acc. to IEC 61000-4-53000 A
GOST Certificate9AKK107992A1640
KEMA Certificate9AKK107492A6077
ÖVE Certificate9AKK107492A6086