AMF Relay : EC-RXA-V2
| Feature 1 | Display of 3 Phase Mains Parameters: Voltage and Frequency |
|---|---|
| Feature 2 | Display of Generator Parameters: Voltage, Frequency, Speed, Flun Hours |
| Feature 3 | Measurement and display of Load current and Instantaneous load in kW |
| Feature 4 | 34 Programmable Parameters including settings of voltage, frequency, different delay times |
| Feature 5 | Site name and number are programmable |
| Feature 6 | Presentation |
| Feature 7 | Benefits |
| Feature 8 | Contact Our Experts |
| Source URL | https://cselectric.co.in/products-solutions/protectionandmeasurementdevices/amf-relays/ec-rxa-v2/ |
| C&S Taxonomy Path | products-solutions > protectionandmeasurementdevices > amf-relays > ec-rxa-v2 |
| C&S Category | protectionandmeasurementdevices |
| Datasheet URL | https://cselectric.co.in/wp-content/uploads/2016/04/EC-RXA-V2-Catalogue.pdf |
| Presentation | EC-RXA-V2 is a AUTOMATIC/MANUAL Generator controller module including protection for (STAND BY) GEN~SEl’S. It uses single advanced micro controller chip for an easy and trouble free GEN~SET control. it is cost ef fective solution for AMF controlling system. If mains voltage in any phase fails (either voltage or frequency goes out of the selected range) EC-RXA-V2 initiates an automatic GEN-SET start cycle including load transfer by switching the contactors mounted in the panel. After the mains is restored the load will be automatically removed from GEN-SET and transferred to mains.GEN-SET will stop after a set cool down time. During all cycles, generator is fully monitored and protected against any fault. All the alarm occurring at abnormal GEN-SET conditions are detected and displayed on LCD display and if necessary GEN-SET is stopped and hooter gets activated. |
| Benefits | 9 LEDs, 7 Digital inputs and 6 Potential outputs fordriving of relays on external relay card Last 5 Fault records with date and time stamp Logical interlockfor Mains & DG breakerforfail safe operation Wide array of time circuits for start delay, stop delay, mains restoration, re- cooling etc Full engine safety functions: The unit has LLOP, HOT, Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload tripfunctions |
| Download Brochure | Download Brochure <!-- |
| Feature 9 | Download Brochure |
| Feature 10 | 9 LEDs, 7 Digital inputs and 6 Potential outputs fordriving of relays on external relay card |
| Feature 11 | Last 5 Fault records with date and time stamp |
| Feature 12 | Logical interlockfor Mains & DG breakerforfail safe operation |
| Feature 13 | Wide array of time circuits for start delay, stop delay, mains restoration, re- cooling etc |
| Feature 14 | Full engine safety functions: The unit has LLOP, HOT, Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload tripfunctions |
| Summary | EC-RXA-V2 is an automatic/manual generator controller module with protection for (STAND BY) GEN~SEl’S, using a single advanced microcontroller chip. Know more |
| C&S Subcategory | amf-relays |
| AMF Relay : EC-RXA-V2 | FEATURES Display of 3 Phase Mains Parameters: Voltage and Frequency Display of Generator Parameters: Voltage, Frequency, Speed, Flun Hours Measurement and display of Load current and Instantaneous load in kW 34 Programmable Parameters including settings of voltage, frequency, different delay times Site name and number are programmable Presentation Benefits Contact Our Experts Download Brochure EC-RXA-V2 is a AUTOMATIC/MANUAL Generator controller module including protection for (STAND BY) GEN~SEl’S. It uses single advanced micro controller chip for an easy and trouble free GEN~SET control. it is cost ef fective solution for AMF controlling system. If mains voltage in any phase fails (either voltage or frequency goes out of the selected range) EC-RXA-V2 initiates an automatic GEN-SET start cycle including load transfer by switching the contactors mounted in the panel. After the mains is restored the load will be automatically removed from GEN-SET and transferred to mains.GEN-SET will stop after a set cool down time. During all cycles, generator is fully monitored and protected against any fault. All the alarm occurring at abnormal GEN-SET conditions are detected and displayed on LCD display and if necessary GEN-SET is stopped and hooter gets activated. 9 LEDs, 7 Digital inputs and 6 Potential outputs fordriving of relays on external relay card Last 5 Fault records with date and time stamp Logical interlockfor Mains & DG breakerforfail safe operation Wide array of time circuits for start delay, stop delay, mains restoration, re- cooling etc Full engine safety functions: The unit has LLOP, HOT, Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload tripfunctions <span class="wpcf7-form-control-wrap" data-name="S |