C&S Electric

Full Featured Engine Controller : EGC-250

رقم القطعة: CS-EGC-250-ENGINE-CONTROL-RELAY

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Full Featured Engine Controller : EGC-250

المواصفات

DownloadDownload Brochure <!--
Feature 1Display of 3 Phase Mains Parameters: Voltage and Frequency
Feature 2Display of 3 Phase Generator Parameters: Voltage, Frequency, Speed, Run Hours
Feature 3Metering Energy for both Mains& DG
Feature 4Wide range of Analog Sensor Selection
Feature 5All DI/DOs are programmable
Feature 6Presentation
Feature 7Benefits
Feature 8Contact Our Experts
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/amf-relays/egc-250-engine-control-relay/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > amf-relays > egc-250-engine-control-relay
C&S Categoryprotectionandmeasurementdevices
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2016/05/EGC-250-Catalogue.pdf
PresentationEGC-150 is a MANUAL/REMOTE Generator controller cum supervisory module designed to control the engine via push buttons on front panel or remotely operated key switch/digital inputs. During all cycles, generator is fully monitored and protected against any fault. All the alarm occurring at abnormal GEN»SET conditions are detected and displayed on LCD display and if necessary GEN-SET is stopped and hooter gets activated. EGC-150 operates in one of the two modes as described below. The operating mode must be selected from MMI. These modes are Manual Mode & Remote Mode. Manual Mode: This mode is selected through parameter menu. In this mode EGC-150 will be operated manually. It will only respond to START and STOP keys for Generator start and stop operation. These keys will be functional only when manual mode is active. Before giving start command to Generator one must ensure that Generator CB is open. Start key should be pressed until the engine reaches the threshold speed. Generator CB may now be closed provided that the Mains CB is open. Pressing of Stop key turns off the engine. Before giving stop command from keypad, the generator CB must be open. The generator is stopped without going through recooling phase. In this mode all protection for Gen Set like under voltage, over voltage, under/over frequency, HCT, LLOP etc. will remain active. Remote Mode: This mode is selected through parameter menu. In this mode EGO-150 will be operated remotely. It will only respond to Remote Start DI signal and Remote Stop DI signal for DG start and stop operation. Before giving start command to Generator one must ensure that Generator CB is open. Remote Start DI signal should be held down until the engine reaches the threshold speed. Generator CB may now be closed provided that the Mains CB is open. Remote Stop Dl signal turns off the engine. Before giving stop command from DI, the generator CB must be open. The generator is stopped without going thru re-cooling phase. In this mode all protection for GEN- SEl’ like under voltage, over voltage, HCT, LLOP etc. will remain active.
BenefitsFault records with date and time stamp Event records with date and time stamp Logical interlock for Mains & DG breaker for fail safe operation Measurement and display of Load current and Instantaneous load in kW Wide range of Programmable Parameters including settings of voltage, frequency, different delay times Wide array oftime circuits for start delay, stop delay, re- cooling etc Full engine safety functions: The unit has Low Lube Oil Pressure (LLOP), Hi Coolant Temperature (HGT), Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload trip functions
Feature 9Download
Feature 10Fault records with date and time stamp
Feature 11Event records with date and time stamp
Feature 12Logical interlock for Mains & DG breaker for fail safe operation
Feature 13Measurement and display of Load current and Instantaneous load in kW
Feature 14Wide range of Programmable Parameters including settings of voltage, frequency, different delay times
Feature 15Wide array oftime circuits for start delay, stop delay, re- cooling etc
Feature 16Full engine safety functions: The unit has Low Lube Oil Pressure (LLOP), Hi Coolant Temperature (HGT), Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload trip functions
SummaryC&S EGC-250 comes with the features to display of 3 Phase Mains & Generator Parameters, metering energy & wide range of Analog Sensor Selection
C&S Subcategoryamf-relays
Full Featured Engine Controller : EGC-250RANGE Output Contacts: No. of potential output contacts:6 ; Type of contacts: Potential Input Contacts: No. of digital inputs: 5 ; No. of analog inputs: 3 FEATURES Display of 3 Phase Mains Parameters: Voltage and Frequency Display of 3 Phase Generator Parameters: Voltage, Frequency, Speed, Run Hours Metering Energy for both Mains& DG Wide range of Analog Sensor Selection All DI/DOs are programmable Presentation Benefits Contact Our Experts Download EGC-150 is a MANUAL/REMOTE Generator controller cum supervisory module designed to control the engine via push buttons on front panel or remotely operated key switch/digital inputs. During all cycles, generator is fully monitored and protected against any fault. All the alarm occurring at abnormal GEN»SET conditions are detected and displayed on LCD display and if necessary GEN-SET is stopped and hooter gets activated. EGC-150 operates in one of the two modes as described below. The operating mode must be selected from MMI. These modes are Manual Mode & Remote Mode. Manual Mode: This mode is selected through parameter menu. In this mode EGC-150 will be operated manually. It will only respond to START and STOP keys for Generator start and stop operation. These keys will be functional only when manual mode is active. Before giving start command to Generator one must ensure that Generator CB is open. Start key should be pressed until the engine reaches the threshold speed. Generator CB may now be closed provided that the Mains CB is open. Pressing of Stop key turns off the engine. Before giving stop command from keypad, the generator CB must be open. The generator is stopped without going through recooling phase. In this mode all protection for Gen Set like under voltage, over voltage, under/over frequency, HCT, LLOP etc. will remain active. Remote Mode: This mode is selected through parameter menu. In this mode EGO-150 will be operated remotely. It will only respond to Remote Start DI signal and Remote Stop DI signal for DG start and stop operation. Before giving start command to Generator one must ensure that Generator CB is open. Remote Start DI signal should be held down until the engine reaches the threshold speed. Generator CB may now be closed provided that the Mains CB is open. Remote Stop Dl signal turns off the engine. Before giving stop command from DI, the generator CB must be open. The generator is stopped without going thru re-cooling phase. In this mode all protection for GEN- SEl’ like under voltage, over voltage, HCT, LLOP etc. will remain active. Fault records with date and time stamp Event records with date and time stamp Logical interlock for Mains & DG breaker for fail safe operation Measurement and display of Load current and Instantaneous load in kW Wide range of Programmable Parameters including settings of voltage, frequency, different delay times Wide array oftime circuits for start delay, stop delay, re- cooling etc Full engine safety functions: The unit has Low Lube Oil Pressure (LLOP), Hi Coolant Temperature (HGT), Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload trip functions <input type="hidden" name="_wpcf7cf_visible_groups" value="[]" /