C&S Electric

6/8/12 Stages Conventional APFC Relay with Auto C/K mode : CSPF-100

رقم القطعة: CS-6812-STAGES-CONVENTIONAL-APFC-RELAY-AUTO-CK-MODE-CSPF-100

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

6/8/12 Stages Conventional APFC Relay with Auto C/K mode : CSPF-100

المواصفات

Feature 1Effective PF Control. Up to 12* capacitor banks controllable
Feature 2Seven segment display for user interface
Feature 3Auto / Manual Operation
Feature 4Wide range of measuring voltage Input
Feature 5Measurement & Display of line parameters like V, I, P, Q, S, Cos Ø
Feature 6Indication of active Capacitor Bank through LEDs
Feature 7Wide range of Programmable parameter including CT ratio, Target
Feature 8Cos Ø value, C/K Ratio, Capacitor Bank switching program, control algorithm etc.
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/apfc-series/6812-stages-conventional-apfc-relay-auto-ck-mode-cspf-100/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > apfc-series > 6812-stages-conventional-apfc-relay-auto-ck-mode-cspf-100
C&S Categoryprotectionandmeasurementdevices
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2020/07/CSPF-100-Catalog-1.pdf
PresentationCSPF-100, Power Factor Controller is designed for Automatic / Manual control of external Capacitor Banks in 3 Phase 4 Wire or 3 Phase 3 Wire & Single Phase LT distribution systems to allow the power factor of the installation to be stabilized to the desired value. The controller employs the state of the art micro-controller design for measurement & visualization of various system parameters. APPLICATION: In all in-comers of an Electrical Plant Fixed power factor correction for individual load (e.g: Motor, Transformer etc.) Hi-tech Software Parks, Buildings and Shopping Malls
BenefitsFully automatic compensation Saving in installation cost of conductors Reduced electric utility Bills & Increased System Capacity Reduction of Power Losses
Download BrochureDownload Brochure <!--
Feature 9Suitable for various wiring scheme
Feature 10Protection & Indication on abnormal condition such as Over /
Feature 11Under Compensation, Over Voltage, Over/Under Current etc.
Feature 12Optional FAN control output based on temperature sensing
Feature 13Field accessible test mode for relay contact check
Feature 14Automatic C/K set-up mode
Feature 15Potential Free Alarm contact on abnormal conditions
Feature 16Presentation
Feature 17Benefits
Feature 18Contact Our Experts
Feature 19Download Brochure
Feature 20Fully automatic compensation
Feature 21Saving in installation cost of conductors
SummaryC&S Conventional APFC Relay with Auto C/K mode is designed for Automatic/Manual control of external Capacitor Banks—a wide range of measuring voltage Input.
Feature 22Reduced electric utility Bills & Increased System Capacity
Feature 23Reduction of Power Losses
C&S Subcategoryapfc-series
6/8/12 Stages Conventional APFC Relay with Auto C/K mode : CSPF-100FEATURES Effective PF Control. Up to 12* capacitor banks controllable Seven segment display for user interface Auto / Manual Operation Wide range of measuring voltage Input Measurement & Display of line parameters like V, I, P, Q, S, Cos Ø Indication of active Capacitor Bank through LEDs Wide range of Programmable parameter including CT ratio, Target Cos Ø value, C/K Ratio, Capacitor Bank switching program, control algorithm etc. Suitable for various wiring scheme Protection & Indication on abnormal condition such as Over / Under Compensation, Over Voltage, Over/Under Current etc. Optional FAN control output based on temperature sensing Field accessible test mode for relay contact check Automatic C/K set-up mode Potential Free Alarm contact on abnormal conditions Presentation Benefits Contact Our Experts Download Brochure CSPF-100, Power Factor Controller is designed for Automatic / Manual control of external Capacitor Banks in 3 Phase 4 Wire or 3 Phase 3 Wire & Single Phase LT distribution systems to allow the power factor of the installation to be stabilized to the desired value. The controller employs the state of the art micro-controller design for measurement & visualization of various system parameters. APPLICATION: In all in-comers of an Electrical Plant Fixed power factor correction for individual load (e.g: Motor, Transformer etc.) Hi-tech Software Parks, Buildings and Shopping Malls Fully automatic compensation Saving in installation cost of conductors Reduced electric utility Bills & Increased System Capacity Reduction of Power Losses