| Feature 1 | Effective PF Control. Up to 12* capacitor banks controllable |
|---|---|
| Feature 2 | Seven segment display for user interface |
| Feature 3 | Auto / Manual Operation |
| Feature 4 | Wide range of measuring voltage Input |
| Feature 5 | Measurement & Display of line parameters like V, I, P, Q, S, Cos Ø |
| Feature 6 | Indication of active Capacitor Bank through LEDs |
| Feature 7 | Wide range of Programmable parameter including CT ratio, Target |
| Feature 8 | Cos Ø value, C/K Ratio, Capacitor Bank switching program, control algorithm etc. |
| Source URL | https://cselectric.co.in/products-solutions/protectionandmeasurementdevices/apfc-series/6812-stages-conventional-apfc-relay-auto-ck-mode-cspf-100/ |
| C&S Taxonomy Path | products-solutions > protectionandmeasurementdevices > apfc-series > 6812-stages-conventional-apfc-relay-auto-ck-mode-cspf-100 |
| C&S Category | protectionandmeasurementdevices |
| Datasheet URL | https://cselectric.co.in/wp-content/uploads/2020/07/CSPF-100-Catalog-1.pdf |
| Presentation | CSPF-100, Power Factor Controller is designed for Automatic / Manual control of external Capacitor Banks in 3 Phase 4 Wire or 3 Phase 3 Wire & Single Phase LT distribution systems to allow the power factor of the installation to be stabilized to the desired value. The controller employs the state of the art micro-controller design for measurement & visualization of various system parameters. APPLICATION: In all in-comers of an Electrical Plant Fixed power factor correction for individual load (e.g: Motor, Transformer etc.) Hi-tech Software Parks, Buildings and Shopping Malls |
| Benefits | Fully automatic compensation Saving in installation cost of conductors Reduced electric utility Bills & Increased System Capacity Reduction of Power Losses |
| Download Brochure | Download Brochure <!-- |
| Feature 9 | Suitable for various wiring scheme |
| Feature 10 | Protection & Indication on abnormal condition such as Over / |
| Feature 11 | Under Compensation, Over Voltage, Over/Under Current etc. |
| Feature 12 | Optional FAN control output based on temperature sensing |
| Feature 13 | Field accessible test mode for relay contact check |
| Feature 14 | Automatic C/K set-up mode |
| Feature 15 | Potential Free Alarm contact on abnormal conditions |
| Feature 16 | Presentation |
| Feature 17 | Benefits |
| Feature 18 | Contact Our Experts |
| Feature 19 | Download Brochure |
| Feature 20 | Fully automatic compensation |
| Feature 21 | Saving in installation cost of conductors |
| Summary | C&S Conventional APFC Relay with Auto C/K mode is designed for Automatic/Manual control of external Capacitor Banks—a wide range of measuring voltage Input. |
| Feature 22 | Reduced electric utility Bills & Increased System Capacity |
| Feature 23 | Reduction of Power Losses |
| C&S Subcategory | apfc-series |
| 6/8/12 Stages Conventional APFC Relay with Auto C/K mode : CSPF-100 | FEATURES Effective PF Control. Up to 12* capacitor banks controllable Seven segment display for user interface Auto / Manual Operation Wide range of measuring voltage Input Measurement & Display of line parameters like V, I, P, Q, S, Cos Ø Indication of active Capacitor Bank through LEDs Wide range of Programmable parameter including CT ratio, Target Cos Ø value, C/K Ratio, Capacitor Bank switching program, control algorithm etc. Suitable for various wiring scheme Protection & Indication on abnormal condition such as Over / Under Compensation, Over Voltage, Over/Under Current etc. Optional FAN control output based on temperature sensing Field accessible test mode for relay contact check Automatic C/K set-up mode Potential Free Alarm contact on abnormal conditions Presentation Benefits Contact Our Experts Download Brochure CSPF-100, Power Factor Controller is designed for Automatic / Manual control of external Capacitor Banks in 3 Phase 4 Wire or 3 Phase 3 Wire & Single Phase LT distribution systems to allow the power factor of the installation to be stabilized to the desired value. The controller employs the state of the art micro-controller design for measurement & visualization of various system parameters. APPLICATION: In all in-comers of an Electrical Plant Fixed power factor correction for individual load (e.g: Motor, Transformer etc.) Hi-tech Software Parks, Buildings and Shopping Malls Fully automatic compensation Saving in installation cost of conductors Reduced electric utility Bills & Increased System Capacity Reduction of Power Losses |