C&S Electric

CSNEX-I 350 - Intelligent Measuring & Protection Device

رقم القطعة: CS-CSNEX-I-350-INTELLIGENT-MEASURING-PROTECTION-DEVICE-2

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

CSNEX-I 350 - Intelligent Measuring & Protection Device

المواصفات

DownloadDownload Brochure <!--
Feature 1Rated Data: Rated current lp : 1A or 5A , Rated frequency: 50 Hz/60 Hz
Feature 2Drop out to Pickup Ratio: >96 %
Feature 3Power consumption in current circuit: At |p=1A 0.1 VA, At |p=5A 0.2 VA
Feature 41A & 5A rated CT input (programmable)
Feature 5Draw out with self CT shorting
Feature 6DI/DO programmable matrix
Feature 7Protection blocking through DI
Feature 8Three phase time over-current protection
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/current-protection/csnex-i-350-intelligent-measuring-protection-device-2/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > current-protection > csnex-i-350-intelligent-measuring-protection-device-2
C&S Categoryprotectionandmeasurementdevices
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2016/04/mPro-Basic-100-Catalogue.pdf
PresentationCSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformer segment. CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fast protection solution in a single unit. In this family of CSENEX series, the CSENEX-I 150 is an advanced feeder protection solution which has fast, sensitive and secure protection forfeeder internal & external faults. CSENEX-l offers different model based features to coverthe wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks and substations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51): The independent two stages are available for phase fault protection. For l> the user may independently select definite time delay or inverse time delay with different type of curves. The second Hi—Set stage can be configured with definite time only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite time delay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite time only.
Feature 9Three phase instantaneous protection
Feature 10Earth time over-current and earth instantaneous over current
Feature 11Circuit breakerfallure detection
Feature 12Trip circuit supervision
Feature 13Cold Load pickup
Feature 14Harmonic Blocking
Feature 15Fault recorder
Feature 16Event recorder
Feature 17Communication (Local & Remote)
Feature 18Presentation
Feature 19Contact Our Experts
Feature 20Download
SummaryCSENEX Series, by C&S Electric, is a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformer segment – offering multi protection and monitoring in a single unit
C&S Subcategorycurrent-protection
CSNEX-I 350 - Intelligent Measuring & Protection DeviceRANGE Rated Data: Rated current lp : 1A or 5A , Rated frequency: 50 Hz/60 Hz Drop out to Pickup Ratio: >96 % Power consumption in current circuit: At |p=1A 0.1 VA, At |p=5A 0.2 VA FEATURES 1A & 5A rated CT input (programmable) Draw out with self CT shorting DI/DO programmable matrix Protection blocking through DI Three phase time over-current protection Three phase instantaneous protection Earth time over-current and earth instantaneous over current Circuit breakerfallure detection Trip circuit supervision Cold Load pickup Harmonic Blocking Fault recorder Event recorder Communication (Local & Remote) Presentation Contact Our Experts Download CSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformer segment. CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fast protection solution in a single unit. In this family of CSENEX series, the CSENEX-I 150 is an advanced feeder protection solution which has fast, sensitive and secure protection forfeeder internal & external faults. CSENEX-l offers different model based features to coverthe wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks and substations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51): The independent two stages are available for phase fault protection. For l> the user may independently select definite time delay or inverse time delay with different type of curves. The second Hi—Set stage can be configured with definite time only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite time delay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite time only. <input size="40" maxlength="400" class="wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email Your Email" id="YourEmail" aria-required="true" aria-invalid="false" placeholder="Your Email *" value="" type="email"