CSNEX-I 350 - Intelligent Measuring & Protection Device
رقم القطعة: CS-CSNEX-I-350-INTELLIGENT-MEASURING-PROTECTION-DEVICE-2
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: CS-CSNEX-I-350-INTELLIGENT-MEASURING-PROTECTION-DEVICE-2
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
CSNEX-I 350 - Intelligent Measuring & Protection Device
| Download | Download Brochure <!-- |
|---|---|
| Feature 1 | Rated Data: Rated current lp : 1A or 5A , Rated frequency: 50 Hz/60 Hz |
| Feature 2 | Drop out to Pickup Ratio: >96 % |
| Feature 3 | Power consumption in current circuit: At |p=1A 0.1 VA, At |p=5A 0.2 VA |
| Feature 4 | 1A & 5A rated CT input (programmable) |
| Feature 5 | Draw out with self CT shorting |
| Feature 6 | DI/DO programmable matrix |
| Feature 7 | Protection blocking through DI |
| Feature 8 | Three phase time over-current protection |
| Source URL | https://cselectric.co.in/products-solutions/protectionandmeasurementdevices/current-protection/csnex-i-350-intelligent-measuring-protection-device-2/ |
| C&S Taxonomy Path | products-solutions > protectionandmeasurementdevices > current-protection > csnex-i-350-intelligent-measuring-protection-device-2 |
| C&S Category | protectionandmeasurementdevices |
| Datasheet URL | https://cselectric.co.in/wp-content/uploads/2016/04/mPro-Basic-100-Catalogue.pdf |
| Presentation | CSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformer segment. CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fast protection solution in a single unit. In this family of CSENEX series, the CSENEX-I 150 is an advanced feeder protection solution which has fast, sensitive and secure protection forfeeder internal & external faults. CSENEX-l offers different model based features to coverthe wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks and substations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51): The independent two stages are available for phase fault protection. For l> the user may independently select definite time delay or inverse time delay with different type of curves. The second Hi—Set stage can be configured with definite time only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite time delay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite time only. |
| Feature 9 | Three phase instantaneous protection |
| Feature 10 | Earth time over-current and earth instantaneous over current |
| Feature 11 | Circuit breakerfallure detection |
| Feature 12 | Trip circuit supervision |
| Feature 13 | Cold Load pickup |
| Feature 14 | Harmonic Blocking |
| Feature 15 | Fault recorder |
| Feature 16 | Event recorder |
| Feature 17 | Communication (Local & Remote) |
| Feature 18 | Presentation |
| Feature 19 | Contact Our Experts |
| Feature 20 | Download |
| Summary | CSENEX Series, by C&S Electric, is a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformer segment – offering multi protection and monitoring in a single unit |
| C&S Subcategory | current-protection |
| CSNEX-I 350 - Intelligent Measuring & Protection Device | RANGE Rated Data: Rated current lp : 1A or 5A , Rated frequency: 50 Hz/60 Hz Drop out to Pickup Ratio: >96 % Power consumption in current circuit: At |p=1A 0.1 VA, At |p=5A 0.2 VA FEATURES 1A & 5A rated CT input (programmable) Draw out with self CT shorting DI/DO programmable matrix Protection blocking through DI Three phase time over-current protection Three phase instantaneous protection Earth time over-current and earth instantaneous over current Circuit breakerfallure detection Trip circuit supervision Cold Load pickup Harmonic Blocking Fault recorder Event recorder Communication (Local & Remote) Presentation Contact Our Experts Download CSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformer segment. CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fast protection solution in a single unit. In this family of CSENEX series, the CSENEX-I 150 is an advanced feeder protection solution which has fast, sensitive and secure protection forfeeder internal & external faults. CSENEX-l offers different model based features to coverthe wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks and substations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51): The independent two stages are available for phase fault protection. For l> the user may independently select definite time delay or inverse time delay with different type of curves. The second Hi—Set stage can be configured with definite time only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite time delay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite time only. <input size="40" maxlength="400" class="wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email Your Email" id="YourEmail" aria-required="true" aria-invalid="false" placeholder="Your Email *" value="" type="email" |