C&S Electric

Innovative Feeder Protection Relay with Disturbance Recording : CSENEX-I 350

رقم القطعة: CS-CSNEX-I-350-INTELLIGENT-MEASURING-PROTECTION-DEVICE

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Innovative Feeder Protection Relay with Disturbance Recording : CSENEX-I 350

المواصفات

DownloadDownload Brochure <!--
Feature 1Rated Data: Rated current lp : 1A or 5A , Ra ted frequency: 50 Hz/60 Hz
Feature 2Drop out to Pickup Ratio: >96 %
Feature 3Power consumption in current circuit: At |p=1A 0.1 VA, At |p=5A 0.2 VA
Feature 41A & 5A rated CT input (programmable)
Feature 5Draw out with self CT shorting
Feature 6DI/DO programmable matrix
Feature 7Protection blocking through DI
Feature 8Three phase time over-current protection
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/current-protection/csnex-i-350-intelligent-measuring-protection-device/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > current-protection > csnex-i-350-intelligent-measuring-protection-device
C&S Categoryprotectionandmeasurementdevices
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2020/06/CSENEX-I-350-Catalog.pdf
PresentationCSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformer segment. CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fast protection solution in a single unit. In this family of CSENEX series, the CSENEX-I 350 is an advanced feeder protection solution which has fast, sensitive and secure protection forfeeder internal & external faults. CSENEX-l offers different model based features to coverthe wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks and substations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51): The independent two stages are available for phase fault protection. For l> the user may independently select definite time delay or inverse time delay with different type of curves. The second Hi—Set stage can be configured with definite time only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite time delay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite time only.
BenefitsThree phase instantaneous protection Protection against Cold Load Earth time over—cun’ent and earth instantaneous over current Circuit breaker failure detection Trip circuit supervision Thermal Over load Auto Re-closing function Four sets of setting groups Programmable Scheme Logic Disturbance recording Fault recorder
Feature 9Presentation
Feature 10Benefits
Feature 11Contact Our Experts
Feature 12Download
Feature 13Three phase instantaneous protection
Feature 14Protection against Cold Load
Feature 15Earth time over—cun’ent and earth instantaneous over current
Feature 16Circuit breaker failure detection
Feature 17Trip circuit supervision
Feature 18Thermal Over load
Feature 19Auto Re-closing function
Feature 20Four sets of setting groups
Feature 21Programmable Scheme Logic
SummaryC&S Electric's Series of CSENEX offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformer segment.
Feature 22Disturbance recording
Feature 23Fault recorder
C&S Subcategorycurrent-protection
Innovative Feeder Protection Relay with Disturbance Recording : CSENEX-I 350RANGE Rated Data: Rated current lp : 1A or 5A , Ra ted frequency: 50 Hz/60 Hz Drop out to Pickup Ratio: >96 % Power consumption in current circuit: At |p=1A 0.1 VA, At |p=5A 0.2 VA FEATURES 1A & 5A rated CT input (programmable) Draw out with self CT shorting DI/DO programmable matrix Protection blocking through DI Three phase time over-current protection Presentation Benefits Contact Our Experts Download CSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformer segment. CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fast protection solution in a single unit. In this family of CSENEX series, the CSENEX-I 350 is an advanced feeder protection solution which has fast, sensitive and secure protection forfeeder internal & external faults. CSENEX-l offers different model based features to coverthe wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks and substations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51): The independent two stages are available for phase fault protection. For l> the user may independently select definite time delay or inverse time delay with different type of curves. The second Hi—Set stage can be configured with definite time only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite time delay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite time only. Three phase instantaneous protection Protection against Cold Load Earth time over—cun’ent and earth instantaneous over current Circuit breaker failure detection Trip circuit supervision Thermal Over load Auto Re-closing function Four sets of setting groups Programmable Scheme Logic Disturbance recording Fault recorder <input size="40" maxlength="400" class="wpcf7-form-control wpcf7-text wpcf7-validates-as-required Your Name" id="YourName" aria-required="true" aria-invalid="false" placeholder="Your Name *" value="" type="text