C&S Electric

Numerical Non-Directional Current Protection relay (Non-Draw out with RS485) : IRI PRO-V4

رقم القطعة: CS-LRLPRO-V4-OVER-CURRENT-PROTECTION-RELAY

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Numerical Non-Directional Current Protection relay (Non-Draw out with RS485) : IRI PRO-V4

المواصفات

DownloadDownload Brochure <!--
Feature 1Rated Data: Rated current lp: 1A or 5A , Rated frequency Fn : 50 Hz
Feature 2Drop out to Pickup Ratio: >96%
Feature 3Protection-Front Panel: lP-54
Feature 4Three Phase Time Over-current Protection
Feature 5Three Phase Instantaneous Protection
Feature 61A & 5A rated CT input (programmable)
Feature 7Earth Time Over-current And Earth Instantaneous Over Current
Feature 8Circuit Breaker Failure Protection
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/current-protection/lrlpro-v4-over-current-protection-relay/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > current-protection > lrlpro-v4-over-current-protection-relay
C&S Categoryprotectionandmeasurementdevices
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2020/06/IRI-Pro-V4-Catalogue.pdf
PresentationIRIPRO Series offers a compact Over-current protection solution for distribution/feeder segment. IRIPRO Family of protective relays are numeric relays that provides protection and monitoring with reliable and fast protection solution in a single unit with programmable digital outputs. The IRIPRO-V3 relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks and substations. They can also be used as part of backup protection scheme for feeders, transformers and generators. Protection Function Three Phase Over-current Protection (50/51): The independent two stages are available for phase fault protection. For first stage (l>) the user may independently select definite time delay or inverse time delay with different type of curves. The second Hi-Set stage (l>>) can be configured with definite time only. Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite time delay or inverse time delay with different type of curves. The second Hi—Set (le>>) stage can be configured with definite time only. Relay Latching (86): Flelay can be configured to Latch /Unlatch depending on configuration. (Latching is possible in presence ofAuxiliary supply voltage only). Circuit Breaker Failure Protection (50 BF): The CB Failure Protection is based on supervision of phase and earth currents after tripping events. The test criterion is whether all phase currents have dropped to less than 5% of In within tCBFP. If one or more of the phase currents have not dropped to specified current within this time, CB failure is detected and the assigned output relay is activated. Reset Delay: This parameter introduces a delay in opening of relay contacts, when the current goes below the drop out value for over current, short circuit and earth faults. This parameter will not work when manual reset mode is selected.
BenefitsFault Recorder Programmable Digital Output USB Communication
Feature 9Presentation
Feature 10Benefits
Feature 11Contact Our Experts
Feature 12Download
Feature 13Fault Recorder
Feature 14Programmable Digital Output
Feature 15USB Communication
SummaryC&S Electric Numerical Current protection relays provide protection & monitoring for use as part of backup protection for transformers & generators. Know more
C&S Subcategorycurrent-protection
Numerical Non-Directional Current Protection relay (Non-Draw out with RS485) : IRI PRO-V4RANGE Rated Data: Rated current lp: 1A or 5A , Rated frequency Fn : 50 Hz Drop out to Pickup Ratio: >96% Protection-Front Panel: lP-54 FEATURES Three Phase Time Over-current Protection Three Phase Instantaneous Protection 1A & 5A rated CT input (programmable) Earth Time Over-current And Earth Instantaneous Over Current Circuit Breaker Failure Protection Presentation Benefits Contact Our Experts Download IRIPRO Series offers a compact Over-current protection solution for distribution/feeder segment. IRIPRO Family of protective relays are numeric relays that provides protection and monitoring with reliable and fast protection solution in a single unit with programmable digital outputs. The IRIPRO-V3 relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks and substations. They can also be used as part of backup protection scheme for feeders, transformers and generators. Protection Function Three Phase Over-current Protection (50/51): The independent two stages are available for phase fault protection. For first stage (l>) the user may independently select definite time delay or inverse time delay with different type of curves. The second Hi-Set stage (l>>) can be configured with definite time only. Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite time delay or inverse time delay with different type of curves. The second Hi—Set (le>>) stage can be configured with definite time only. Relay Latching (86): Flelay can be configured to Latch /Unlatch depending on configuration. (Latching is possible in presence ofAuxiliary supply voltage only). Circuit Breaker Failure Protection (50 BF): The CB Failure Protection is based on supervision of phase and earth currents after tripping events. The test criterion is whether all phase currents have dropped to less than 5% of In within tCBFP. If one or more of the phase currents have not dropped to specified current within this time, CB failure is detected and the assigned output relay is activated. Reset Delay: This parameter introduces a delay in opening of relay contacts, when the current goes below the drop out value for over current, short circuit and earth faults. This parameter will not work when manual reset mode is selected. Fault Recorder Programmable Digital Output USB Communication <input type="hidden" name="_wpcf7cf_options" value="{"form_id":84938,"conditions":[],"settings":{"animation":"yes","animation_intime":200,"animation_outtime":200,"conditions_ui":"normal","notice_dismissed":false,"repeater_remove_button":"bottom","notice_dismissed_update-cf7-6.1&qu