C&S Electric

Innovative Self Power Protection Relay for RMUs : CSDPR-V2-200

رقم القطعة: CS-CSDPR-V2-200-INTELLIGENT-MEASURING-PROTECTION-DEVICE

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Innovative Self Power Protection Relay for RMUs : CSDPR-V2-200

المواصفات

Feature 1Relay get energize either from Current, Aux. voltage, front USB or internal battery.
Feature 2DEFT & Inverse characteristics for Over current & Earth fault, individually selected for phase & earth fault
Feature 3Potential pulse output for direct triggering of the circuit breaker coil. Potential-free alarm contacts are also available
Feature 4Self-supervision function
Feature 5Remote trip & Remote protection block input DI
Feature 6Two sets of setting groups
Feature 7DI/DO programmable matrix
Feature 8Protection blocking through DI
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/self-powered-relays-rmu/csdpr-v2-200-intelligent-measuring-protection-device/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > self-powered-relays-rmu > csdpr-v2-200-intelligent-measuring-protection-device
C&S Categoryprotectionandmeasurementdevices
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2025/11/CSDPR-V2-200-D-L_H-N-_T-M_I-catalog.pdf
BenefitsRelay draws its operating energy directly from the current transformers (CTs) in the protected circuit, ensuring continuous operation even during a main power outage or auxiliary supply failure. It can also be energised from an auxiliary voltage supply (AC/DC), an internal battery, or a front USB port (for configuration), providing flexibility during commissioning and maintenance. The device is designed to store enough energy to trip the circuit breaker even with low current faults It integrates various protections in a single compact unit, including: Over current Short circuit Earth fault Earth fault High set Under current Cold load pickup Inrush blocking Unbalance / Asymmetric Circuit breaker failure Trip circuit supervision The relay stores the last several fault and event records with a date and time stamp. Its small and compact design facilitates integration into Ring Main Units and other space-constrained switchboards. Features an RS-485 Modbus communication port (rear) and a front USB port for PC/laptop interfacing, enabling remote monitoring, control, and easy configuration using software like CSE LIVELINK. An LCD display and push buttons allow for easy viewing of measured parameters, fault data, and setting adjustments.
Download BrochureDownload Brochure <!--
Feature 9Wide operating ranges of Aux. supply voltage (AC/DC)
Feature 10Last 5 Fault and 10 Event records with Date & Time stamp
Feature 11Rear RS-485 communication
Feature 12Front USB communication for PC / Laptop interface
Feature 13Introduction
Feature 14Benefits
Feature 15Contact Our Experts
Feature 16Download Brochure
Feature 17Relay draws its operating energy directly from the current transformers (CTs) in the protected circuit, ensuring continuous operation even during a main power outage or auxiliary supply failure.
Feature 18It can also be energised from an auxiliary voltage supply (AC/DC), an internal battery, or a front USB port (for configuration), providing flexibility during commissioning and maintenance.
Feature 19The device is designed to store enough energy to trip the circuit breaker even with low current faults
Feature 20It integrates various protections in a single compact unit, including: Over current
Feature 21Short circuit
SummaryIn the Protection relay, CSDPR-V2 200 is numeric multi powered Over-current relay specially designed for ring main units & feeder protection.
Feature 22Earth fault
Feature 23Earth fault High set
C&S Subcategoryself-powered-relays-rmu
Feature 24Under current
Feature 25Cold load pickup
Feature 26Inrush blocking
Feature 27Unbalance / Asymmetric
Feature 28Circuit breaker failure
IntroductionC&S Electric CSDPR-V2-200 is a self-powered, numeric over-current protection relay for Ring Main Units (RMUs) and feeder protection. Current, auxiliary voltage, USB, or an internal battery can power the device. The unit offers multiple protection functions, including overcurrent, short-circuit, and earth fault protection, as well as inverse and definite-time characteristics.
Feature 29Trip circuit supervision
Innovative Self Power Protection Relay for RMUs : CSDPR-V2-200FEATURES Relay get energize either from Current, Aux. voltage, front USB or internal battery. DEFT & Inverse characteristics for Over current & Earth fault, individually selected for phase & earth fault Potential pulse output for direct triggering of the circuit breaker coil. Potential-free alarm contacts are also available Self-supervision function Remote trip & Remote protection block input DI Two sets of setting groups DI/DO programmable matrix Protection blocking through DI Wide operating ranges of Aux. supply voltage (AC/DC) Last 5 Fault and 10 Event records with Date & Time stamp Rear RS-485 communication Front USB communication for PC / Laptop interface Introduction Benefits Contact Our Experts Download Brochure C&S Electric CSDPR-V2-200 is a self-powered, numeric over-current protection relay for Ring Main Units (RMUs) and feeder protection. Current, auxiliary voltage, USB, or an internal battery can power the device. The unit offers multiple protection functions, including overcurrent, short-circuit, and earth fault protection, as well as inverse and definite-time characteristics. Relay draws its operating energy directly from the current transformers (CTs) in the protected circuit, ensuring continuous operation even during a main power outage or auxiliary supply failure. It can also be energised from an auxiliary voltage supply (AC/DC), an internal battery, or a front USB port (for configuration), providing flexibility during commissioning and maintenance. The device is designed to store enough energy to trip the circuit breaker even with low current faults It integrates various protections in a single compact unit, including: Over current Short circuit Earth fault Earth fault High set Under current Cold load pickup Inrush blocking Unbalance / Asymmetric Circuit breaker failure Trip circuit supervision The relay stores the last several fault and event records with a date and time stamp. Its small and compact design facilitates integration into Ring Main Units and other space-constrained switchboards. Features an RS-485 Modbus communication port (rear) and a front USB port for PC/laptop interfacing, enabling remote monitoring, control, and easy configuration using software like CSE LIVELINK. An LCD display and push buttons allow for easy viewing of measured parameters, fault data, and setting adjustments. <input size="40" maxlength="400" class="wpcf7-form-control wpcf7-text wpcf7-validate