Innovative Self Power Protection Relay for RMUs : CSDPR-V2-200
رقم القطعة: CS-CSDPR-V2-200-INTELLIGENT-MEASURING-PROTECTION-DEVICE
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: CS-CSDPR-V2-200-INTELLIGENT-MEASURING-PROTECTION-DEVICE
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
Innovative Self Power Protection Relay for RMUs : CSDPR-V2-200
| Feature 1 | Relay get energize either from Current, Aux. voltage, front USB or internal battery. |
|---|---|
| Feature 2 | DEFT & Inverse characteristics for Over current & Earth fault, individually selected for phase & earth fault |
| Feature 3 | Potential pulse output for direct triggering of the circuit breaker coil. Potential-free alarm contacts are also available |
| Feature 4 | Self-supervision function |
| Feature 5 | Remote trip & Remote protection block input DI |
| Feature 6 | Two sets of setting groups |
| Feature 7 | DI/DO programmable matrix |
| Feature 8 | Protection blocking through DI |
| Source URL | https://cselectric.co.in/products-solutions/protectionandmeasurementdevices/self-powered-relays-rmu/csdpr-v2-200-intelligent-measuring-protection-device/ |
| C&S Taxonomy Path | products-solutions > protectionandmeasurementdevices > self-powered-relays-rmu > csdpr-v2-200-intelligent-measuring-protection-device |
| C&S Category | protectionandmeasurementdevices |
| Datasheet URL | https://cselectric.co.in/wp-content/uploads/2025/11/CSDPR-V2-200-D-L_H-N-_T-M_I-catalog.pdf |
| Benefits | Relay draws its operating energy directly from the current transformers (CTs) in the protected circuit, ensuring continuous operation even during a main power outage or auxiliary supply failure. It can also be energised from an auxiliary voltage supply (AC/DC), an internal battery, or a front USB port (for configuration), providing flexibility during commissioning and maintenance. The device is designed to store enough energy to trip the circuit breaker even with low current faults It integrates various protections in a single compact unit, including: Over current Short circuit Earth fault Earth fault High set Under current Cold load pickup Inrush blocking Unbalance / Asymmetric Circuit breaker failure Trip circuit supervision The relay stores the last several fault and event records with a date and time stamp. Its small and compact design facilitates integration into Ring Main Units and other space-constrained switchboards. Features an RS-485 Modbus communication port (rear) and a front USB port for PC/laptop interfacing, enabling remote monitoring, control, and easy configuration using software like CSE LIVELINK. An LCD display and push buttons allow for easy viewing of measured parameters, fault data, and setting adjustments. |
| Download Brochure | Download Brochure <!-- |
| Feature 9 | Wide operating ranges of Aux. supply voltage (AC/DC) |
| Feature 10 | Last 5 Fault and 10 Event records with Date & Time stamp |
| Feature 11 | Rear RS-485 communication |
| Feature 12 | Front USB communication for PC / Laptop interface |
| Feature 13 | Introduction |
| Feature 14 | Benefits |
| Feature 15 | Contact Our Experts |
| Feature 16 | Download Brochure |
| Feature 17 | Relay draws its operating energy directly from the current transformers (CTs) in the protected circuit, ensuring continuous operation even during a main power outage or auxiliary supply failure. |
| Feature 18 | It can also be energised from an auxiliary voltage supply (AC/DC), an internal battery, or a front USB port (for configuration), providing flexibility during commissioning and maintenance. |
| Feature 19 | The device is designed to store enough energy to trip the circuit breaker even with low current faults |
| Feature 20 | It integrates various protections in a single compact unit, including: Over current |
| Feature 21 | Short circuit |
| Summary | In the Protection relay, CSDPR-V2 200 is numeric multi powered Over-current relay specially designed for ring main units & feeder protection. |
| Feature 22 | Earth fault |
| Feature 23 | Earth fault High set |
| C&S Subcategory | self-powered-relays-rmu |
| Feature 24 | Under current |
| Feature 25 | Cold load pickup |
| Feature 26 | Inrush blocking |
| Feature 27 | Unbalance / Asymmetric |
| Feature 28 | Circuit breaker failure |
| Introduction | C&S Electric CSDPR-V2-200 is a self-powered, numeric over-current protection relay for Ring Main Units (RMUs) and feeder protection. Current, auxiliary voltage, USB, or an internal battery can power the device. The unit offers multiple protection functions, including overcurrent, short-circuit, and earth fault protection, as well as inverse and definite-time characteristics. |
| Feature 29 | Trip circuit supervision |
| Innovative Self Power Protection Relay for RMUs : CSDPR-V2-200 | FEATURES Relay get energize either from Current, Aux. voltage, front USB or internal battery. DEFT & Inverse characteristics for Over current & Earth fault, individually selected for phase & earth fault Potential pulse output for direct triggering of the circuit breaker coil. Potential-free alarm contacts are also available Self-supervision function Remote trip & Remote protection block input DI Two sets of setting groups DI/DO programmable matrix Protection blocking through DI Wide operating ranges of Aux. supply voltage (AC/DC) Last 5 Fault and 10 Event records with Date & Time stamp Rear RS-485 communication Front USB communication for PC / Laptop interface Introduction Benefits Contact Our Experts Download Brochure C&S Electric CSDPR-V2-200 is a self-powered, numeric over-current protection relay for Ring Main Units (RMUs) and feeder protection. Current, auxiliary voltage, USB, or an internal battery can power the device. The unit offers multiple protection functions, including overcurrent, short-circuit, and earth fault protection, as well as inverse and definite-time characteristics. Relay draws its operating energy directly from the current transformers (CTs) in the protected circuit, ensuring continuous operation even during a main power outage or auxiliary supply failure. It can also be energised from an auxiliary voltage supply (AC/DC), an internal battery, or a front USB port (for configuration), providing flexibility during commissioning and maintenance. The device is designed to store enough energy to trip the circuit breaker even with low current faults It integrates various protections in a single compact unit, including: Over current Short circuit Earth fault Earth fault High set Under current Cold load pickup Inrush blocking Unbalance / Asymmetric Circuit breaker failure Trip circuit supervision The relay stores the last several fault and event records with a date and time stamp. Its small and compact design facilitates integration into Ring Main Units and other space-constrained switchboards. Features an RS-485 Modbus communication port (rear) and a front USB port for PC/laptop interfacing, enabling remote monitoring, control, and easy configuration using software like CSE LIVELINK. An LCD display and push buttons allow for easy viewing of measured parameters, fault data, and setting adjustments. <input size="40" maxlength="400" class="wpcf7-form-control wpcf7-text wpcf7-validate |