Innovative Self Power Protection Relay for RMUs : CSDPR-V2-300
رقم القطعة: CS-INNOVATIVE-SELF-POWER-PROTECTION-RELAY-FOR-RMUS-CSDPR-V2-300
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: CS-INNOVATIVE-SELF-POWER-PROTECTION-RELAY-FOR-RMUS-CSDPR-V2-300
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
Innovative Self Power Protection Relay for RMUs : CSDPR-V2-300
| Feature 1 | Over current, Short Circuit, Earth Fault and Earth Fault High set protection |
|---|---|
| Feature 2 | Potential pulse output for direct triggering of the circuit breaker coil. |
| Feature 3 | Two sets of protection setting groups |
| Feature 4 | DEFT & Inverse characteristics for O/C and E/F, individually selected for phase & earth fault |
| Feature 5 | Potential free alarm contacts available |
| Feature 6 | Unbalance / Asymmetric protection |
| Feature 7 | Circuit breaker failure protection |
| Feature 8 | Switch on to fault (SOTF) protection* |
| Source URL | https://cselectric.co.in/products-solutions/protectionandmeasurementdevices/self-powered-relays-rmu/innovative-self-power-protection-relay-for-rmus-csdpr-v2-300/ |
| C&S Taxonomy Path | products-solutions > protectionandmeasurementdevices > self-powered-relays-rmu > innovative-self-power-protection-relay-for-rmus-csdpr-v2-300 |
| C&S Category | protectionandmeasurementdevices |
| Datasheet URL | https://cselectric.co.in/wp-content/uploads/2025/11/CSDPR-V2-300-D-L_H-P-_-T-Catalog.pdf |
| Benefits | The C&S Electric CSDPR-V2-300 self-powered relay offers significant benefits in reliability and cost-effectiveness by eliminating the need for an external auxiliary power supply for core protection functions, which is crucial for applications like Ring Main Units (RMUs). The primary advantage is, Relay draws its operating energy directly from the current transformers (CTs) in the protected circuit, ensuring continuous operation even during a main power outage or auxiliary supply failure. It can also be energised from an auxiliary voltage supply (AC/DC), an internal battery, or a front USB port (for configuration), providing flexibility during commissioning and maintenance. The device is designed to store enough energy to trip the circuit breaker even with low current faults It integrates various protections in a single compact unit, including: Over-current (O/C) Earth fault (E/F) and Earth fault high set Unbalance/Asymmetric protection Circuit Breaker Failure Protection Switch on to Fault * Trip circuit supervision * The relay stores the last several fault and event records with a date and time stamp. Its small and compact design facilitates integration into Ring Main Units and other space-constrained switchboards. Features an RS-485 Modbus communication port (rear) and a front USB port for PC/laptop interfacing, enabling remote monitoring, control, and easy configuration using software like CSE LIVELINK. An LCD display and push buttons allow for easy viewing of measured parameters, fault data, and setting adjustments. |
| Download Brochure | Download Brochure <!-- |
| Feature 9 | Harmonic blocking (via DFT Filter) to avoid any Inrush phenomena to protect against unwanted tripping |
| Feature 10 | 2 Optically isolated digital inputs for Remote Trip, Protection blocking (model dependent) |
| Feature 11 | 4 Digital Output contacts for annunciation |
| Feature 12 | Relay gets energised either from Current, Aux. voltage, Front USB (whichever is available) |
| Feature 13 | Last 5 Fault and 10 Event records with Date & Time stamp |
| Feature 14 | USB port for data downloading/uploading via PC / Laptop |
| Feature 15 | RS-485 port with communication protocol of IEC 103 or MODBUS for SCADA communication |
| Feature 16 | Wide operating range of the Aux supply voltage (AC/DC) |
| Feature 17 | Introduction |
| Feature 18 | Benefits |
| Feature 19 | Contact Our Experts |
| Feature 20 | Download Brochure |
| Feature 21 | The C&S Electric CSDPR-V2-300 self-powered relay offers significant benefits in reliability and cost-effectiveness by eliminating the need for an external auxiliary power supply for core protection functions, which is crucial for applications like Ring Main Units (RMUs). |
| Summary | C&S Electric CSDPR-V2-300 self-powered relay offers advanced RMU protection with O/C, E/F, and unbalance features. Ensure reliable feeder safety. Contact us today. |
| Feature 22 | The primary advantage is, Relay draws its operating energy directly from the current transformers (CTs) in the protected circuit, ensuring continuous operation even during a main power outage or auxiliary supply failure. |
| Feature 23 | It can also be energised from an auxiliary voltage supply (AC/DC), an internal battery, or a front USB port (for configuration), providing flexibility during commissioning and maintenance. |
| C&S Subcategory | self-powered-relays-rmu |
| Feature 24 | The device is designed to store enough energy to trip the circuit breaker even with low current faults |
| Feature 25 | It integrates various protections in a single compact unit, including: Over-current (O/C) |
| Feature 26 | Earth fault (E/F) and Earth fault high set |
| Feature 27 | Unbalance/Asymmetric protection |
| Feature 28 | Circuit Breaker Failure Protection |
| Introduction | CSDPR-V2-300 is a numeric multi-powered Overcurrent relay specially designed for ring main units & feeder protection. It consists of all the necessary protection and monitoring functions required for RMU. The advanced Controller continuously monitors line load current and E/F currents with standard CTs. These measured values are then used for different protection functions overcurrent protection, E/F protection etc. Metering is available on LCD display. The power module derives power from the current flowing through the line; therefore, external power supply is not required. Relay provides pulse output to Trip the RMU or compact CB having low low-energy series tripping coil. Along with that, Relay provides potential-free output contacts for Alarm/Annunciation. |
| Feature 29 | Switch on to Fault * |
| Feature 30 | Trip circuit supervision * |
| Innovative Self Power Protection Relay for RMUs : CSDPR-V2-300 | FEATURES Over current, Short Circuit, Earth Fault and Earth Fault High set protection Potential pulse output for direct triggering of the circuit breaker coil. Two sets of protection setting groups DEFT & Inverse characteristics for O/C and E/F, individually selected for phase & earth fault Potential free alarm contacts available Unbalance / Asymmetric protection Circuit breaker failure protection Switch on to fault (SOTF) protection* Harmonic blocking (via DFT Filter) to avoid any Inrush phenomena to protect against unwanted tripping 2 Optically isolated digital inputs for Remote Trip, Protection blocking (model dependent) 4 Digital Output contacts for annunciation Relay gets energised either from Current, Aux. voltage, Front USB (whichever is available) Last 5 Fault and 10 Event records with Date & Time stamp USB port for data downloading/uploading via PC / Laptop RS-485 port with communication protocol of IEC 103 or MODBUS for SCADA communication Wide operating range of the Aux supply voltage (AC/DC) Introduction Benefits Contact Our Experts Download Brochure CSDPR-V2-300 is a numeric multi-powered Overcurrent relay specially designed for ring main units & feeder protection. It consists of all the necessary protection and monitoring functions required for RMU. The advanced Controller continuously monitors line load current and E/F currents with standard CTs. These measured values are then used for different protection functions overcurrent protection, E/F protection etc. Metering is available on LCD display. The power module derives power from the current flowing through the line; therefore, external power supply is not required. Relay provides pulse output to Trip the RMU or compact CB having low low-energy series tripping coil. Along with that, Relay provides potential-free output contacts for Alarm/Annunciation. The C&S Electric CSDPR-V2-300 self-powered relay offers significant benefits in reliability and cost-effectiveness by eliminating the need for an external auxiliary power supply for core protection functions, which is crucial for applications like Ring Main Units (RMUs). The primary advantage is, Relay draws its operating energy directly from the current transformers (CTs) in the protected circuit, ensuring continuous operation even during a main power outage or auxiliary supply failure. It can also be energised from an auxiliary voltage supply (AC/DC), an internal battery, or a front USB port (for configuration), providing flexibility during commissioning and maintenance. The device is designed to store enough energy to trip the circuit breaker even with low current faults It integrates various protections in a single compact unit, including: Over-current (O/C) Earth fault (E/F) and Earth fault high set Unbalance/Asymmetric protection Circuit Breaker Failure Protection Switch on to Fault * Trip circuit supervision * The relay stores the last several fault and event records with a date and time stamp. Its small and compact design facilitates integration into Ring Main Units and other space-constrained switchboards. Features an RS-485 Modbus communication port (rear) and a front USB port for PC/laptop interfacing, enabling remote monitoring, control, and easy configuration using software like CSE LIVELINK. An LCD display and push buttons allow for easy viewing of measured parameters, fault data, and setting adjustments. <input type="hidden" name="_wpcf7_container_post" value="13195 |