C&S Electric

Advance Transformer Protection & Monitoring IED : CSEZEN-T200

رقم القطعة: CS-ADVANCE-TRANSFORMER-PROTECTION-MONITORING-IED-CSEZEN-T200

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Advance Transformer Protection & Monitoring IED : CSEZEN-T200

المواصفات

Feature 1Programmable Rated Current 1A & 5A for HV & LV winding
Feature 250/60Hz Nominal Frequency (Site selectable)
Feature 3Draw-out Relay with Self CT shorting modular design
Feature 4User configurable Digital Input / Digital Output *
Feature 5Intelligent key for DI & DO status, details of fault pickup & status of last fault occurred
Feature 620 Fault & 500 Event records with date and time stamp
Feature 71200 cycles of Disturbance recording
Feature 8IEC 61850 / IEC-103 / MODBUS communication protocol *
Source URLhttps://cselectric.co.in/products-solutions/protectionandmeasurementdevices/transformer-protection/advance-transformer-protection-monitoring-ied-csezen-t200/
C&S Taxonomy Pathproducts-solutions > protectionandmeasurementdevices > transformer-protection > advance-transformer-protection-monitoring-ied-csezen-t200
C&S Categoryprotectionandmeasurementdevices
Datasheet URLhttps://cselectric.co.in/wp-content/uploads/2026/04/CSEZEN-T-200-0_1_4-D-0_1-L_H-A_B_C-0_S-E-H-standard.pdf
PresentationCSEZEN series offers a multi-functional comprehensive smart protection solution for the Feeder, Generator, Motor &Transformer segment. CSEZEN family of protective relays are advanced numerical relays that provide multi protection and monitoring with reliable and fast protection solutions in a single unit. In this family of CSEZEN series, the CSEZEN-T is an advanced Transformer protection relay designed for controlling, protecting and monitoring industrial installations, public distribution networks and substations. CSEZEN-T also provides an automation solution for power control. It complies with IEC 60870-5-103, IEC 61850, Modbus protocol for high integration of protection & control. CSEZEN-T offers the following features in a compact & smart flush mounting enclosure. APPLICATION: CSEZEN-T relay will cover a wide range of protection functions required for the Transformer segment. It can be used as part of a protection scheme for transformers and generator transformers. CSEZEN-T relays can also provide back-up protection for HV and EHV transmission systems.
BenefitsA transformer protection relay offers important benefits by detecting faults and abnormal conditions, preventing damage to transformers, extending their lifespan and ensuring the safety and stability of the system. They reduce costly downtime by enabling quick fault isolation, save on repair and replacement expenses and help meet regulatory compliance requirements for electrical reliability. They also contribute to the integrity of the overall power system by providing vital data for maintenance.
Download BrochureDownload Brochure <!--
Feature 9Interactive HMI with USB Plug & Play support
Feature 10Wide Range of Aux Supply
Feature 11Common configuration Software-Designer suite M12
Feature 12Presentation
Feature 13Benefits
Feature 14Contact Our Experts
Feature 15Download Brochure
SummaryCSEZEN series, by C&S Electric, offers a multi-functional smart protection solution for feeder, generator, motor & transformer segments. Explore the range here.
C&S Subcategorytransformer-protection
Advance Transformer Protection & Monitoring IED : CSEZEN-T200FEATURES Programmable Rated Current 1A & 5A for HV & LV winding 50/60Hz Nominal Frequency (Site selectable) Draw-out Relay with Self CT shorting modular design User configurable Digital Input / Digital Output * Intelligent key for DI & DO status, details of fault pickup & status of last fault occurred 20 Fault & 500 Event records with date and time stamp 1200 cycles of Disturbance recording IEC 61850 / IEC-103 / MODBUS communication protocol * Interactive HMI with USB Plug & Play support Wide Range of Aux Supply Common configuration Software-Designer suite M12 Presentation Benefits Contact Our Experts Download Brochure CSEZEN series offers a multi-functional comprehensive smart protection solution for the Feeder, Generator, Motor &Transformer segment. CSEZEN family of protective relays are advanced numerical relays that provide multi protection and monitoring with reliable and fast protection solutions in a single unit. In this family of CSEZEN series, the CSEZEN-T is an advanced Transformer protection relay designed for controlling, protecting and monitoring industrial installations, public distribution networks and substations. CSEZEN-T also provides an automation solution for power control. It complies with IEC 60870-5-103, IEC 61850, Modbus protocol for high integration of protection & control. CSEZEN-T offers the following features in a compact & smart flush mounting enclosure. APPLICATION: CSEZEN-T relay will cover a wide range of protection functions required for the Transformer segment. It can be used as part of a protection scheme for transformers and generator transformers. CSEZEN-T relays can also provide back-up protection for HV and EHV transmission systems. A transformer protection relay offers important benefits by detecting faults and abnormal conditions, preventing damage to transformers, extending their lifespan and ensuring the safety and stability of the system. They reduce costly downtime by enabling quick fault isolation, save on repair and replacement expenses and help meet regulatory compliance requirements for electrical reliability. They also contribute to the integrity of the overall power system by providing vital data for maintenance. <input size="40" maxlength="400" clas