Numerical Voltage Protection Relay (Non-Draw out) : IRU PRO-UOR
رقم القطعة: CS-IRU-PRO-AC-VOLTAGE-RELAY-27-59-59N-47-59D
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: CS-IRU-PRO-AC-VOLTAGE-RELAY-27-59-59N-47-59D
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
Numerical Voltage Protection Relay (Non-Draw out) : IRU PRO-UOR
| Feature 1 | Multi-function Voltage Protection for Distribution |
|---|---|
| Feature 2 | Numeric DSP technology-based relay |
| Feature 3 | Draw-out Relay with Self CT shorting modular design |
| Feature 4 | Two groups of configuration parameters |
| Feature 5 | Voltage supervision, each with two steps under and over voltage detection |
| Feature 6 | Single / Three-phase selection |
| Feature 7 | 50/60Hz Nominal Frequency (Site selectable) |
| Feature 8 | Interactive HMI with USB Plug & Play support |
| Source URL | https://cselectric.co.in/products-solutions/protectionandmeasurementdevices/voltage/iru-pro-ac-voltage-relay-27-59-59n-47-59d/ |
| C&S Taxonomy Path | products-solutions > protectionandmeasurementdevices > voltage > iru-pro-ac-voltage-relay-27-59-59n-47-59d |
| C&S Category | protectionandmeasurementdevices |
| Datasheet URL | https://cselectric.co.in/wp-content/uploads/2026/04/IRU-PRO-U-O-R-Catalog.pdf |
| Presentation | PRO range of relays provides reliable and high-performance protection. The IRU-PRO is a relay for AC Voltage supervision with universal application, it protects the three-phase network against over, undervoltage, unbalance or earth faults in isolated networks. Besides the pure RMS value measurement of the line voltage, the IRU-PRO evaluates the symmetrical components (U1, U2 & U0 sequence system). By evaluating these components relay IRUPRO can detect the phase sequence, voltage unbalance and earth faults. |
| Benefits | IRUPRO Relays safeguard expensive electrical devices, motors, transformers and appliances from damage caused by voltage fluctuations (overvoltage and undervoltage). Overvoltage can damage insulation and cause equipment burnout, while undervoltage causes motors to draw too much current, resulting in overheating and damage. Relay instantly disconnects the circuit to prevent these issues. When equipment operates under safe and optimal voltage conditions, It increases the longevity of connected devices, reducing the frequency of costly repairs. Enhanced Safety and Risk Reduction The relay’s automatic and fast tripping action localises the fault and minimises the duration of system disruption. Recording detailed information about fault events (time, duration, voltage waveform).Allowing the system to automatically re-energise after a set time once the voltage returns to normal limits. |
| Download Brochure | Download Brochure <!-- |
| Feature 9 | User configurable Digital Input / Digital Output |
| Feature 10 | 10 Fault & 50 Event records with date and time stamp |
| Feature 11 | IEC-103 / MODBUS communication protocol |
| Feature 12 | Front-end live link simulation support for testing of relay even without 3 phase injection voltage source |
| Feature 13 | Inverse as well as Definite Trip timing curve selection for under/over voltage |
| Feature 14 | Display of measuring values of the line voltages and system voltages U0, U1 & U2 as RMS values |
| Feature 15 | Block on under voltage in case of Power failure (user selectable) |
| Feature 16 | Suitable for Star/Delta connection |
| Feature 17 | Assignment matrix for output relays for all protection |
| Feature 18 | Offline Trip Test mode |
| Feature 19 | Presentation |
| Feature 20 | Benefits |
| Feature 21 | Contact Our Experts |
| Summary | C&S offers Numerical Voltage Protection Relay that protects three-phase network against over, under-voltage, unbalanced, or earth faults in isolated networks. |
| Feature 22 | Download Brochure |
| Feature 23 | IRUPRO Relays safeguard expensive electrical devices, motors, transformers and appliances from damage caused by voltage fluctuations (overvoltage and undervoltage). |
| C&S Subcategory | voltage |
| Feature 24 | Overvoltage can damage insulation and cause equipment burnout, while undervoltage causes motors to draw too much current, resulting in overheating and damage. Relay instantly disconnects the circuit to prevent these issues. |
| Feature 25 | When equipment operates under safe and optimal voltage conditions, It increases the longevity of connected devices, reducing the frequency of costly repairs. |
| Feature 26 | Enhanced Safety and Risk Reduction |
| Feature 27 | The relay’s automatic and fast tripping action localises the fault and minimises the duration of system disruption. |
| Feature 28 | Recording detailed information about fault events (time, duration, voltage waveform).Allowing the system to automatically re-energise after a set time once the voltage returns to normal limits. |
| Numerical Voltage Protection Relay (Non-Draw out) : IRU PRO-UOR | FEATURES Multi-function Voltage Protection for Distribution Numeric DSP technology-based relay Draw-out Relay with Self CT shorting modular design Two groups of configuration parameters Voltage supervision, each with two steps under and over voltage detection Single / Three-phase selection 50/60Hz Nominal Frequency (Site selectable) Interactive HMI with USB Plug & Play support User configurable Digital Input / Digital Output 10 Fault & 50 Event records with date and time stamp IEC-103 / MODBUS communication protocol Front-end live link simulation support for testing of relay even without 3 phase injection voltage source Inverse as well as Definite Trip timing curve selection for under/over voltage Display of measuring values of the line voltages and system voltages U0, U1 & U2 as RMS values Block on under voltage in case of Power failure (user selectable) Suitable for Star/Delta connection Assignment matrix for output relays for all protection Offline Trip Test mode Presentation Benefits Contact Our Experts Download Brochure PRO range of relays provides reliable and high-performance protection. The IRU-PRO is a relay for AC Voltage supervision with universal application, it protects the three-phase network against over, undervoltage, unbalance or earth faults in isolated networks. Besides the pure RMS value measurement of the line voltage, the IRU-PRO evaluates the symmetrical components (U1, U2 & U0 sequence system). By evaluating these components relay IRUPRO can detect the phase sequence, voltage unbalance and earth faults. IRUPRO Relays safeguard expensive electrical devices, motors, transformers and appliances from damage caused by voltage fluctuations (overvoltage and undervoltage). Overvoltage can damage insulation and cause equipment burnout, while undervoltage causes motors to draw too much current, resulting in overheating and damage. Relay instantly disconnects the circuit to prevent these issues. When equipment operates under safe and optimal voltage conditions, It increases the longevity of connected devices, reducing the frequency of costly repairs. Enhanced Safety and Risk Reduction The relay’s automatic and fast tripping action localises the fault and minimises the duration of system disruption. Recording detailed information about fault events (time, duration, voltage waveform).Allowing the system to automatically re-energise after a set time once the voltage returns to normal limits. <input size="40" maxlength="400" class="wpcf7-form-control wpcf7-text wpcf7-validates-as-required Your Name" id="YourName" aria-required="true" aria-invalid="false |