Mitsubishi Electric

FR-A842-10940-2-60P - High performance and high functionality inverter FR-A800 Series

رقم القطعة: FR-A842-10940-2-60P_7294

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

FR-A842-10940-2-60P - High performance and high functionality inverter FR-A800 Series

المواصفات

SeriesFR-A800
Model nameFR-A842-10940-2-60P
Basic information / Model nameFR-A842-10940-2-60P
Basic information / OverviewHigh performance and high functionality inverter FR-A800 Series
Basic information / Sales statusOn sale
Listed / SeriesFR-A800
Listed / Model nameFR-A842-10940-2-60P
Basic information / Conformance standardcULus CE(EMC) CE(LVD)
TypeThree-phase 400 V class Separated converter Parallel operation
Inverter capacity (kW)450.0
Cooling systemForced air cooling
Control / Control method / CommonSoft-PWM control/High carrier frequency PWM control
Control / Control method / Induction motorSelectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, and Vector control*10
Control / Output frequency range / Induction motor0.2~120 Hz
Control / Frequency setting and resolution / Analog input0.015 Hz/60 Hz at 0 to 10 V/12 bits (terminals 2 and 4) 0.03 Hz/60 Hz at 0 to 5 V/11 bits or 0 to 20 mA/11 bits (terminals 2 and 4), at 0 to ±10 V/12 bits (terminal 1) 0.06 Hz/60 Hz at 0 to ±5 V/11 bits (terminal 1)
Control / Frequency setting and resolution / Digital input0.01 Hz
Control / Frequency accuracy / Analog inputWithin ±0.2 % of the maximum output frequency (25 °C ±10 °C)
Control / Frequency accuracy / Digital input0.01 % or less of the set output frequency
Control / Voltage/frequency characteristicsBase frequency can be set from 0 to 120 Hz. Constant-torque/variable-torque pattern or adjustable 5 points V/F can be selected.
Control / Starting torque / Induction motorThe following is the specifications for the ND rating. 30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V/F control) 150 % at 0.5 Hz (Advanced magnetic flux vector control) 150 % at 0.3 Hz (Real sensorless vector control) 150 % at 0 Hz (Vector control*10)
Control / Torque boostManual torque boost (induction motor only)
Control / Acceleration/deceleration time setting0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode, backlash countermeasures acceleration/deceleration modes are available.
Control / DC injection brake / Induction motorOperation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable
Control / Stall prevention operation levelActivation range of stall prevention operation (LD rating : 0 to 150 %, ND rating : 0 to 220 %). Whether to use the stall prevention or not can be selected. (V/F control, Advanced magnetic flux vector control)
Control / Torque limit levelTorque limit value can be set (0 to 400 % variable). (Real sensorless vector control, Vector control*10)
Operation / Frequency setting signal / Number of analog input3
Operation / Frequency setting signal / Specification of analog inputTerminals 2 and 4 : 0 to 10 V/0 to 5 V/4 to 20 mA (0 to 20 mA) Terminal 1 : -10 to +10 V/-5 to +5 V
Operation / Frequency setting signal / Digital inputInput using the setting dial of the operation panel or parameter unit. Input of four-digit BCD (Binary-coded decimal) or 16-bit binary (when the option FR-A8AX is installed).
Operation / Start signalForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Operation / Input signal / Number of input signal (Contact input)12
Operation / Input signal / Pulse train input100 k pulses/s
Operation / Input signal / Input terminal function selectable signalLow-speed operation command, Middle-speed operation command, High-speed operation command, Second function selection, Terminal 4 input selection, Jog operation selection, Selection of automatic restart after instantaneous power failure/flying start, Output stop, Start self-holding selection, Forward rotation command, Reverse rotation command, Inverter reset The signal to be input can be changed using Pr.178 to Pr.189 (Input terminal function selection).
Operation / Operational functionMaximum and minimum frequency settings, Multi-speed operation, Acceleration/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, Frequency jump, Rotation display, Automatic restart after instantaneous power failure, Electronic bypass sequence, Remote setting, Automatic acceleration/deceleration, Forward/reverse rotation prevention, Operation mode selection, Slip compensation, Droop control, Load torque high-speed frequency control, Speed smoothing control, Traverse, Applied motor selection, Gain tuning, RS-485 communication, PID control, PID precharge function, Easy dancer control, Cooling fan operation selection, Stop selection, Stop-on-contact control, PLC function, Life diagnosis, Maintenance timer, Current average monitor, Multiple rating, Orientation control*10, Speed control, Torque control, Position control, Pre-excitation, Torque limit, Test run, 24 V power supply input for control circuit, Safety stop function, Anti-sway control
Operation / Output signal / Number of output signal (Open collector output)5
Operation / Output signal / Number of output signal (Relay output)2
Operation / Output signal / Output terminal function selectable signalInverter running, Up to frequency, Instantaneous power failure/undervoltage, Overload warning, Output frequency detection, Fault The signal to be output can be changed using Pr.190 to Pr.196 (Output terminal function selection). Fault codes (4 bits) of the inverter can be output from the open collector.
Operation / Output signal / Pulse train output (FM type inverter)50 k pulses/s
Indication / For indication on exter .. put signal for indication on external meters ~34de1a2
Indication / For indication on external meters / Pulse train output (FM type inverter)Max. 2.4 kHz via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection.
Indication / For indication on external meters / Current output (CA type inverter)Max. 20 mA DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection.
Indication / For indication on external meters / Voltage outputMax. 10 V DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.158 AM terminal function selection.
Indication / Operation panel / Status monitoringOutput frequency, output current, output voltage, and frequency setting value are monitored. The item for monitoring can be changed using Pr.52 Operation panel main monitor selection.
Indication / Operation panel / Fault monitoringWhen a protective function is activated, a fault indication is displayed and the output voltage, output current, output frequency, cumulative energization time, date (year, month, day) and time at the occurrence of the fault are stored. Each fault is recorded and the last 8 records can be displayed.
Protective/warning function / Protective functionOvercurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Overcurrent trip, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Overvoltage trip, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay function), Heat sink overheat, Stall prevention stop, Output side earth (ground) fault overcurrent, Output phase loss, External thermal relay operation*14, PTC thermistor operation*14, Option fault, Communication option fault, Parameter storage device fault (control circuit board), PU disconnection*14, Parameter storage device fault (main circuit board), CPU fault, Operation panel power supply short circuit/RS-485 terminals power supply short circuit, 24 VDC power fault, Abnormal output current detection*14, Communication fault (inverter), Analog input fault, USB communication fault, Safety circuit fault, Overspeed occurrence*14, Speed deviation excess detection*10*14, Signal loss detection*10*14, Excessive position fault*10*14, Brake sequence fault*14, 4 mA input fault*14, Pre-charge fault*14, PID signal fault*14, Opposite rotation deceleration fault*14, Internal circuit fault
Protective/warning function / Warning functionFan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Electronic thermal relay function pre-alarm, PU stop, Speed limit indication*14, Parameter copy, Safety stop, Maintenance timer*14, USB host error, Home position return setting error*10*14, Home position return uncompleted*10*14, Operation panel lock*14, Password locked*14, Parameter write error, Copy operation error, 24 V external power supply operation, Continuous operation during communication fault*14
Environment / Surrounding air temperature-10 °C to +50 °C (non-freezing)
Environment / Surrounding air humidity95 % RH or less (non-condensing)
Environment / AmbienceIndoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)
Environment / Altitude/vibrationMaximum 2500 m*13, 2.9 m/s2 or less at 10 to 55 Hz in X, Y, and Z directions
NetworkOption unit : CC-Link IE TSN, CC-Link IE Field Network, CC-Link, SSCNETIII(/H), DeviceNet, PROFIBUS-DPV0, FL remote, EtherCAT, EtherNet/IP, PROFINET, PROFIBUS-DPV1
Listed / Communication optionOption unit : CC-Link IE TSN, CC-Link IE Field Network, CC-Link, SSCNETIII(/H), DeviceNet, PROFIBUS-DPV0, FL remote, EtherCAT, EtherNet/IP, PROFINET, PROFIBUS-DPV1
Listed / Conformance standardcULus CE(EMC) CE(LVD)
Environment / Storage temperature*12-20 °C to +65 °C
Output / Overload current rating*3 / LD120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Output / Overload current rating*3 / ND150 % 60 s, 200 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Output / Voltage*4Three-phase 380 to 500 V
Protective structure / IEC 60529*7IP00
Input power / Power supply voltage430 to 780 VDC
Input power / Control power supply auxiliary inputSingle phase 380 to 500 V 50/60 Hz*6
Input power / Permissible control power supply auxiliary input fluctuationFrequency±5 %, voltage±10 %
Applicable motor capacity (kW) / LD500.0
Applicable motor capacity (kW) / ND450.0
Output / Rated capacity (kVA)*1 / LD733.0
Output / Rated capacity (kVA)*1 / ND660.0
Output / Rated current (A)*2 / LD962.0
Output / Rated current (A)*2 / ND866.0
Approx. mass (kg)*8243.0
Inverter capacity (kW) #22710.0
Applicable motor capacity (kW)*9 / LD800.0 (945.0)
Applicable motor capacity (kW)*9 / ND710.0 (900.0)
Output / Rated capacity (kVA)*1 *9 / LD1173.0 (1466.0)
Output / Rated capacity (kVA)*1 *9 / ND1056.0 (1320.0)
Output / Rated current (A)*2 *9 / LD1539.0 (1924.0)
Output / Rated current (A)*2 *9 / ND1386.0 (1732.0)
Output / Overload current rating*3 / LD #29120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Output / Overload current rating*3 / ND #30150 % 60 s, 200 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Output / Voltage*4 #31Three-phase 380 to 500 V
Input power / Power supply voltage #32430 to 780 VDC
Input power / Control power supply auxiliary input #33Single phase 380 to 500 V 50/60 Hz*6
Input power / Permissible control power supply auxiliary input fluctuation #34Frequency±5 %, voltage±10 %
Protective structure / IEC 60529*7 #35IP00
Cooling system #36Forced air cooling
Approx. mass (kg)*8 #37486.0
Inverter capacity (kW) #391065.0
Applicable motor capacity (kW) / LD #401200.0
Applicable motor capacity (kW) / ND #411065.0
Output / Rated capacity (kVA)*1 / LD #421759.0
Output / Rated capacity (kVA)*1 / ND #431584.0
Output / Rated current (A)*2 / LD #442309.0
Output / Rated current (A)*2 / ND #452078.0
Output / Overload current rating*3 / LD #46120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Output / Overload current rating*3 / ND #47150 % 60 s, 200 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Output / Voltage*4 #48Three-phase 380 to 500 V
Input power / Power supply voltage #49430 to 780 VDC
Input power / Control power supply auxiliary input #50Single phase 380 to 500 V 50/60 Hz*6
Input power / Permissible control power supply auxiliary input fluctuation #51Frequency±5 %, voltage±10 %
Protective structure / IEC 60529*7 #52IP00
Cooling system #53Forced air cooling
Approx. mass (kg)*8 #54729.0