FR-A846-01160-1-60C3 - High performance and high functionality inverter FR-A800 Series
رقم القطعة: FR-A846-01160-1-60C3_7310
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: FR-A846-01160-1-60C3_7310
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
FR-A846-01160-1-60C3 - High performance and high functionality inverter FR-A800 Series
| Series | FR-A800 |
|---|---|
| Model name | FR-A846-01160-1-60C3 |
| Basic information / Model name | FR-A846-01160-1-60C3 |
| Basic information / Overview | High performance and high functionality inverter FR-A800 Series |
| Basic information / Sales status | On sale |
| Listed / Series | FR-A800 |
| Listed / Model name | FR-A846-01160-1-60C3 |
| Basic information / Conformance standard | cULus CE(EMC) CE(LVD) |
| Type | Three-phase 400 V class IP55 compatible model RS-485 model |
| Inverter capacity (kW) | 45.0 |
| Applicable motor capacity (kW)*1 / LD | 55.0 |
| Applicable motor capacity (kW)*1 / ND | 45.0 |
| Output / Rated current (A) / LD | 106.0 |
| Output / Rated current (A) / ND | 86.0 |
| Output / Regenerative braking / Maximum brake torque (ND reference) | 10 % torque/continuous |
| Power supply / Rated input AC voltage and frequency | Three-phase 380 to 500 V, 50/60 Hz*7 |
| Power supply / Permissible AC voltage fluctuation | 323 to 550 V, 50/60 Hz |
| Power supply / Permissible frequency fluctuation | ±5 % |
| Cooling system | Forced air + internal fan |
| Approx. mass (kg) | 64.0 |
| Control / Control method / Common | Soft-PWM control/High carrier frequency PWM control |
| Control / Control method / Induction motor | Selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, and Vector control*10 |
| Control / Control method / PM motor | Selectable among PM sensorless vector control, and Vector control*10 |
| Control / Output frequency range / Induction motor | 0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control, Real sensorless vector control, and Vector control*10.) |
| Control / Output frequency range / PM motor | 0.2 to 400 Hz (not operable at a frequency higher than the maximum motor frequency) |
| Control / Frequency setting and resolution / Analog input | 0.015 Hz/60 Hz at 0 to 10 V/12 bits (terminals 2 and 4) 0.03 Hz/60 Hz at 0 to 5 V/11 bits or 0 to 20 mA/11 bits (terminals 2 and 4), at 0 to ±10 V/12 bits (terminal 1) 0.06 Hz/60 Hz at 0 to ±5 V/11 bits (terminal 1) |
| Control / Frequency setting and resolution / Digital input | 0.01 Hz |
| Control / Frequency accuracy / Analog input | Within ±0.2 % of the maximum output frequency (25 °C ±10 °C) |
| Control / Frequency accuracy / Digital input | 0.01 % or less of the set output frequency |
| Control / Voltage/frequency characteristics | Base frequency can be set from 0 to 590 Hz. Constant-torque/variable-torque pattern or adjustable 5 points V/F can be selected. |
| Control / Starting torque / Induction motor | The following is the specifications for the ND rating. 30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V/F control) 150 % at 0.5 Hz (Advanced magnetic flux vector control) 200 % at 0.3 Hz (0.4K to 3.7K), 150 % at 0.3 Hz (5.5K or higher) (Real sensorless vector control) 200 % at 0 Hz (0.4K to 3.7K), 150 % at 0 Hz (5.5K or higher) (Vector control*10) |
| Control / Starting torque / PM motor | The following is the specifications for the ND rating. 50 % (current synchronization operation) 200 % (when used with MM-CF, 200 % for the 1.5 kW or lower, and 150 % for the 2.0 kW or higher) (high frequency superposition control) |
| Control / Torque boost | Manual torque boost (induction motor only) |
| Control / Acceleration/deceleration time setting | 0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode, backlash countermeasures acceleration/deceleration modes are available. |
| Control / DC injection brake / Induction motor | Operation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable |
| Control / DC injection brake / PM motor | Operation time (0 to 10 s) variable. Operating voltage (operating current) fixed. |
| Control / Stall prevention operation level | Activation range of stall prevention operation (LD rating : 0 to 150 %, ND rating : 0 to 220 %). Whether to use the stall prevention or not can be selected. (V/F control, Advanced magnetic flux vector control) |
| Control / Torque limit level | Torque limit value can be set (0 to 400 % variable). (Real sensorless vector control, Vector control*10, PM sensorless vector control) |
| Operation / Frequency setting signal / Number of analog input | 3 |
| Operation / Frequency setting signal / Specification of analog input | Terminals 2 and 4 : 0 to 10 V/0 to 5 V/4 to 20 mA (0 to 20 mA) Terminal 1 : -10 to +10 V/-5 to +5 V |
| Operation / Frequency setting signal / Digital input | Input using the setting dial of the operation panel or parameter unit. Input of four-digit BCD (Binary-coded decimal) or 16-bit binary (when the option FR-A8AX is installed). |
| Operation / Start signal | Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected. |
| Operation / Input signal / Number of input signal (Contact input) | 12 |
| Operation / Input signal / Pulse train input | 100 k pulses/s |
| Operation / Input signal / Input terminal function selectable signal | Low-speed operation command, Middle-speed operation command, High-speed operation command, Second function selection, Terminal 4 input selection, Jog operation selection, Selection of automatic restart after instantaneous power failure/flying start, Output stop, Start self-holding selection, Forward rotation command, Reverse rotation command, Inverter reset The signal to be input can be changed using Pr.178 to Pr.189 (Input terminal function selection). |
| Operation / Operational function | Maximum and minimum frequency settings, Multi-speed operation, Acceleration/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, DC feeding, Frequency jump, Rotation display, Automatic restart after instantaneous power failure, Electronic bypass sequence, Remote setting, Automatic acceleration/deceleration, Retry function, Carrier frequency selection, Fast-response current limit, Forward/reverse rotation prevention, Operation mode selection, Slip compensation, Droop control, Load torque high-speed frequency control, Speed smoothing control, Traverse, Auto tuning, Applied motor selection, Gain tuning, RS-485 communication, PID control, PID precharge function, Easy dancer control, Cooling fan operation selection, Stop selection, Power failure time deceleration-to-stop function, Stop-on-contact control, PLC function, Life diagnosis, Maintenance timer, Current average monitor, Multiple rating, Orientation control*10, Speed control, Torque control, Position control, Pre-excitation, Torque limit, Test run, 24 V power supply input for control circuit, Safety stop function, Anti-sway control |
| Operation / Output signal / Number of output signal (Open collector output) | 5 |
| Operation / Output signal / Number of output signal (Relay output) | 2 |
| Operation / Output signal / Output terminal function selectable signal | Inverter running, Up to frequency, Instantaneous power failure/undervoltage, Overload warning, Output frequency detection, Fault The signal to be output can be changed using Pr.190 to Pr.196 (Output terminal function selection). Fault codes (4 bits) of the inverter can be output from the open collector. |
| Operation / Output signal / Pulse train output (FM type inverter) | 50 k pulses/s |
| Indication / For indication on exter .. put signal for indication on external meters ~34de1a | 2 |
| Indication / For indication on external meters / Pulse train output (FM type inverter) | Max. 2.4 kHz via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection. |
| Indication / For indication on external meters / Current output (CA type inverter) | Max. 20 mA DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection. |
| Indication / For indication on external meters / Voltage output | Max. 10 V DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.158 AM terminal function selection. |
| Indication / Operation panel / Status monitoring | Output frequency, output current, output voltage, and frequency setting value are monitored. The item for monitoring can be changed using Pr.52 Operation panel main monitor selection. |
| Indication / Operation panel / Fault monitoring | When a protective function is activated, a fault indication is displayed and the output voltage, output current, output frequency, cumulative energization time, date (year, month, day) and time at the occurrence of the fault are stored. Each fault is recorded and the last 8 records can be displayed. |
| Protective/warning function / Protective function | Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay function), Heat sink overheat, Instantaneous power failure, Undervoltage, Input phase loss*12, Stall prevention stop, Loss of synchronism detection*12, Brake transistor alarm detection, Upper limit fault detection, Lower limit fault detection, Output side earth (ground) fault overcurrent, Output short circuit, Output phase loss, External thermal relay operation*12, PTC thermistor operation*12, Option fault, Communication option fault, Parameter storage device fault (control circuit board), PU disconnection, Retry count excess*12, Parameter storage device fault (main circuit board), CPU fault, Operation panel power supply short circuit, 24 VDC power fault, Abnormal output current detection*12, Inrush current limit circuit fault, Communication fault (inverter), Analog input fault, USB communication fault, Safety circuit fault, Overspeed occurrence*12, Speed deviation excess detection*10*12, Signal loss detection*10*12, Excessive position fault*10*12, Brake sequence fault*12, Encoder phase fault*10*12, 4 mA input fault*12, Pre-charge fault*12, PID signal fault*12, Option fault, Opposite rotation deceleration fault*12, Internal circuit fault, User definition error in the PLC function, Abnormal internal temperature, Magnetic pole position unknown*10, External fault during output operation*12 |
| Protective/warning function / Warning function | Fan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Electronic thermal relay function pre-alarm, PU stop, Speed limit indication*12, Safety stop, Maintenance timer*12, USB host error, Home position return setting error*12, Home position return uncompleted*12, Home position return parameter setting error*12, Operation panel lock*12, Password locked*12, Parameter write error, Copy operation error, 24 V external power supply operation, Internal fan alarm, Continuous operation during communication fault |
| Environment / Surrounding air temperature | -10 °C to +40 °C (non-freezing) |
| Environment / Surrounding air humidity | 95 % RH or less (non-condensing) |
| Environment / Ambience | Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt) |
| Environment / Altitude/vibration | Maximum 2500 m*15, 5.9 m/s2*14 or less at 10 to 55 Hz in X, Y, and Z directions |
| Network | RS-485 : Mitsubishi inverter protocol, MODBUS RTU Option unit : CC-Link IE TSN, CC-Link IE Field Network, CC-Link, SSCNETIII(/H), DeviceNet, PROFIBUS-DPV0, FL remote, EtherCAT, EtherNet/IP, PROFINET, PROFIBUS-DPV1 |
| Listed / Communication option | RS-485 : Mitsubishi inverter protocol, MODBUS RTU Option unit : CC-Link IE TSN, CC-Link IE Field Network, CC-Link, SSCNETIII(/H), DeviceNet, PROFIBUS-DPV0, FL remote, EtherCAT, EtherNet/IP, PROFINET, PROFIBUS-DPV1 |
| Listed / Conformance standard | cULus CE(EMC) CE(LVD) |
| Output / Rated capacity (kVA)*2 / LD | 81.0 |
| Output / Rated capacity (kVA)*2 / ND | 66.0 |
| Output / Overload current rating*3 / LD | 120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C |
| Output / Overload current rating*3 / ND | 150 % 60 s, 200 % 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C |
| Output / Voltage*4 | Three-phase 380 to 500 V |
| Power supply / Rated input current (A) without DC reactor*5 / LD | 106.0 |
| Power supply / Rated input current (A) without DC reactor*5 / ND | 86.0 |
| Environment / Storage temperature*11 | -20 °C to +65 °C |
| Protective structure / IEC 60529 | IP55*9 |
| Power supply / Power supply capacity (kVA) without DC reactor*5 / LD | 81.0 |
| Power supply / Power supply capacity (kVA) without DC reactor*5 / ND | 66.0 |
| Protective structure / UL 50 | UL Type12*8 |
| DC reactor | Built-in |