Mitsubishi Electric

FX5-CCLGN-MS - Master/local module for CC-Link IE TSN

رقم القطعة: FX5-CCLGN-MS_3479

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

FX5-CCLGN-MS - Master/local module for CC-Link IE TSN

المواصفات

Basic information / Model nameFX5-CCLGN-MS
Basic information / OverviewMaster/local module for CC-Link IE TSN
Basic information / Sales statusOn sale
Listed / SeriesMELSEC iQ-F
Listed / Model nameFX5-CCLGN-MS
Basic information / Conformance standardUL cUL CE(EMC) CE(RoHS) KC(EMC)
Operating ambient temperatureOperating ambient temperature -20 to 55℃* * When using the FX5-CCLGN-MS manufactured in December 2020 or earlier, the operating ambient temperature is -20 to 50℃.
Number of occupied I/O points8 points
Network topologyLine topology, star topology (Coexistence of line topology and star topology is also possible.)
Maximum station-to-station distance100 m
Connection cableEthernet cable which satisfies standard: Category 5e or higher, straight cable (double shielded, STP)
Communication methodTime sharing method
Transient transmission capacity1920 bytes
Listed / OutlineMaster/local module for CC-Link IE TSN
Listed / Large categoriesManager/local station
Communication speed・1 Gbps ・100Mbps* * This setting can be used for the firmware version "1.010" or later.
Minimum synchronization cycle250.00 μs
CC-Link IE TSN ClassB
Maximum number of link points per network / RX16 K points (16384 points, 2 K bytes)
Maximum number of link points per network / RY16 K points (16384 points, 2 K bytes)
Maximum number of link points per network / RWr8 K points (8192 points, 16 K bytes)
Overall cable distance / Line topology12000 m (when 121 stations are connected)
Maximum number of link points per network / RWw8 K points (8192 points, 16 K bytes)
Overall cable distance / OthersDepends on the system configuration.
Applicable ControllerMX Controller MX-F model*1
Applicable CPU moduleFX5UJ CPU module: Ver. 1.040 or later FX5U CPU module: Ver. 1.210 or later FX5UC CPU module*: Ver. 1.210 or later * FX5-CNV-IFC or FX5-C1PS-5V is required to connect to the FX5UC CPU module.
Applicable engineering tool / GX Works3FX5UJ CPU module: Ver. 1.090U or later FX5U CPU module: Ver. 1.065T or later FX5UC CPU module: Ver. 1.065T or later
Mass (weight)Approx. 0.3 kg
Station typeManager or local station
Station number・Manager station: 0 ・Local station: 1 to 120
Number of connectable modulesOne module can be connected to the CPU module for each station type. ・Manager station: 1 ・Local station: 1
Maximum number of connectable stations / When used as a manager station61
Maximum number of connectable stations / When used as a local station121
Station-based data assurance / When used as a manager station61
Station-based data assurance / When used as a local station121
Maximum number of link points per station / Manager station / RX8 K points (8192 points, 1 K bytes) The maximum number of points for all link devices may not be used simultaneously depending on the number of device stations, or the number of points and assignments of the link devices that are set in the "Network Configuration Settings" of the "Basic Settings".
Maximum number of link points per station / Manager station / RY8 K points (8192 points, 1 K bytes) The maximum number of points for all link devices may not be used simultaneously depending on the number of device stations, or the number of points and assignments of the link devices that are set in the "Network Configuration Settings" of the "Basic Settings".
Maximum number of link points per station / Manager station / RWr4 K points (4096 points, 8 K bytes) The maximum number of points for all link devices may not be used simultaneously depending on the number of device stations, or the number of points and assignments of the link devices that are set in the "Network Configuration Settings" of the "Basic Settings".
Maximum number of link points per station / Manager station / RWw4 K points (4096 points, 8 K bytes) The maximum number of points for all link devices may not be used simultaneously depending on the number of device stations, or the number of points and assignments of the link devices that are set in the "Network Configuration Settings" of the "Basic Settings".
Maximum number of link points per station / Local station / RX16 K points (16384 points, 2 K bytes) The maximum number of points for all link devices may not be used simultaneously depending on the number of device stations, or the number of points and assignments of the link devices that are set in the "Network Configuration Settings" of the "Basic Settings".
Maximum number of link points per station / Local station / RY16 K points (16384 points, 2 K bytes) The maximum number of points for all link devices may not be used simultaneously depending on the number of device stations, or the number of points and assignments of the link devices that are set in the "Network Configuration Settings" of the "Basic Settings".
Maximum number of link points per station / Local station / RWr8 K points (8192 points, 16 K bytes) The maximum number of points for all link devices may not be used simultaneously depending on the number of device stations, or the number of points and assignments of the link devices that are set in the "Network Configuration Settings" of the "Basic Settings".
Maximum number of link points per station / Local station / RWw8 K points (8192 points, 16 K bytes) The maximum number of points for all link devices may not be used simultaneously depending on the number of device stations, or the number of points and assignments of the link devices that are set in the "Network Configuration Settings" of the "Basic Settings".
Network number setting range1 to 239
CC-Link IE TSN Protocol version・2.0* ・1.0 * This setting can be used for the firmware version "1.010" or later.
Data transmission speed・1Gbps ・100Mbps* * This setting can be used for the firmware version "1.010" or later.
Communication mode / 1000BASE-TFull-duplex
Communication mode / 100BASE-TXFull-duplex* * This setting can be used for the firmware version "1.010" or later.
InterfaceRJ45 connector (Auto MDI/MDI-X)
Maximum frame size1518 bytes
Maximum segment length100 m* * For maximum segment length (length between switching hubs), consult the manufacturer of the switching hub used.
Number of cascade connectionsConsult the manufacturer of the switching hub used.
IP versionIPv4
Number of simultaneous open connectio .. nections) / Connection with MELSOFT products ~fcdabb8 connections* * In the case of one connection per device, up to eight devices can be connected.
Number of simultaneous open connectio .. ons) / Connection to SLMP-compatible devices ~77ffbe8 connections* * In the case of one connection per device, up to eight devices can be connected.
External power supply / Power supply voltage24 V DC +20%, -15%
External power supply / Allowable instantaneous power failure timeOperation continues for an instantaneous power failure of 1ms or less.
External power supply / Current consumption220 mA
Dielectric withstand voltage / Betwee .. terminals and ground terminal of CPU module ~656731500 V AC for one minute
Insulation resistance / Between all external terminals and ground terminal of CPU module10 MΩ or higher by 500 V DC insulation resistance tester