Mitsubishi Electric

VS20C-13F410 - Color, 640 × 480 (standard, 2 × image magnification mode)/800 × 600 (2 × image…

رقم القطعة: VS20C-13F410_6617

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

VS20C-13F410 - Color, 640 × 480 (standard, 2 × image magnification mode)/800 × 600 (2 × image…

المواصفات

SeriesVS20
Model nameVS20C-13F410
Basic information / Model nameVS20C-13F410
Basic information / OverviewColor, 640 × 480 (standard, 2 × image magnification mode)/800 × 600 (2 × image magnification mode), processor performance x 2
Basic information / Sales statusDiscontinued
Listed / SeriesVS20
Listed / Model nameVS20C-13F410 2025/09 Discontinued
InstallationM3 screw hole x 4
Weight200 g
Basic information / Conformance standardUL cUL CE(EMC) CE(RoHS) KC(EMC)
Basic information / End of order date2025/07
Basic information / Discontinued date2025/09*Please check or inquire it in each overseas sales company site because the sale situation is different depending on each countries.
Ambient operating temperature0...40°C
Ambient storage temperature–10...60°C
Vibration resistanceIEC 60068-2-6: A vibration of 10 G (10 to 500 Hz at 100 m/s2 with 15 mm width) was applied to each X, Y, and Z direction for 2 hours
Shock resistanceIEC 60068-2-27: 1000 half sinusoidal shocks with 11 G in 10 ms were applied.
Operating atmosphereThere is no danger of corrosive gases, flammable gases, and strong alkaline substances to adhere.
Basic information / Repair support expiration date2032/09
Memory32 MB flash memory Unlimited storage when storing in the remote network device Image processing: 128 MB SDRAM
Power consumption24 V DC ± 10%, 48 W (2.0 A) maximum when the illumination is ON.
Imager type1/3-inch CMOS, 4.80 mm × 3.60 mm (W × H), 3.75 μm sq. pixels
ImageryColor
LensS-Mount/M12, 8 mm (standard), options: 3.6 mm, 6 mm, 12 mm, 16 mm, 25 mm
Bit depth24-bit color
Electronic shutter speed1μs...1000 ms
PatMax RedLine®-
Spreadsheet-
TriggerOpto-isolated image acquisition trigger input × 1, Remote software commands via Ethernet
Discrete inputsEquipped as standard: opto-isolated general-purpose input x 1, option: general purpose input x 7 (available when connecting a CIO-1400 I/O module)
Discrete outputsOpto-isolated high-speed output x 4 Option: High-speed output x 2, general-purpose output x 6: available when connecting a CIO-1400 I/O module
Network communicationCC-Link IE Field Network Basic, SLMP scanner, SLMP, MODBUS®/TCP, EtherNet/IP™, TCP/IP, UDP, FTP, Telnet (native mode), DHCP (default at shipment from the factory), fixed and link local IP address setting
MaterialAluminum housing
DimensionsStraight configuration: 92 mm x 60 mm x 52 mm, Right-angle configuration: 62 mm x 60 mm x 67 mm
Maximum humidityLess than 95% RH, non-condensing
Protective structureIP65 (when all connectors are attached to cables or shielded by a sealing cap)
Listed / ImageryColor
Listed / Image resolution (pixels)640 × 480 (standard) 640 × 480 (2 × image magnification mode) 800 × 600 (2 × image magnification mode)
Listed / Maximum image acquisition speed55 full frames per second
Listed / PatMax RedLine®-
Listed / Spreadsheet-
Image resolution (pixels)*1640 × 480 (standard) 640 × 480 (2 × image magnification mode) 800 × 600 (2 × image magnification mode)
LightingEquipped as standard: LED ring light (white), option: LED ring light (red, blue, near-infrared)
Maximum image acquisition speed*255 full frames per second
Trigger / VoltageON: 15...24 V DC (standard 24 V DC), OFF: 0...5 V DC (standard 0 V DC)
Trigger / Current3.6 mA/12 V DC, 7.5 mA/24 V DC, Resistance: Max. 5.48 kΩ
Discrete inputs / VoltageON: 15...24 V DC (standard 24 V DC), OFF: 0...5 V DC (standard 0 V DC)
Discrete inputs / Current3.6 mA/12 V DC, 7.5 mA/24 V DC, resistance: Max. 5.48 kΩ
Discrete outputs / Voltage28 V DC maximum through external load
Discrete outputs / Current*3ON status: Max. 50 mA (sink or source), leakage current in OFF status: Max. 100 μA, external load resistance: 240 Ω to 10 kΩ Each line is rated at a maximum 50 mA and protected against over-current, short circuits, and transients from switching inductive loads. A protection diode is required for a high inductive load.
Status LEDsPower supply, trigger status, PASS/FAIL status, network, error
RS-232 communication methodR x D, T x D (TIA/EIA-232-F compliant)
ConnectorEthernet connector: 1 channel (M12), power supply, I/O, RS-232 connector: 1 channel (M12)