| Series | MELSERVO-J4 series |
|---|---|
| Model name | MR-J4-100GF4-RJ |
| Basic information / Model name | MR-J4-100GF4-RJ |
| Basic information / Overview | CC-Link IE Field-compatible servo amplifier, 1 kW, 3-phase 380 V AC to 480 V AC |
| Basic information / Sales status | To be discontinued |
| Listed / Series | MELSERVO-J4 series |
| Listed / Model name | MR-J4-100GF4-RJ 2028/03 To be end of order |
| Basic information / Conformance standard | UL CSA CE(EMC) CE(LVD) CE(Machinery) CE(RoHS) UKCA ChinaRoHS KC(EMC) |
| Basic information / End of order date | 2028/03 |
| Basic information / Discontinued date | 2029/03*Please check or inquire it in each overseas sales company site because the sale situation is different depending on each countries. |
| Basic information / Replacement models | MR-J5-100G4-RJ Learn more about our products Compare replacement models and specifications |
| Basic information / Repair support expiration date | 2036/03 |
| Environment / Ambience | Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust |
| Control method | Sine-wave PWM control/current control method |
| Mass [kg] ~81ac87 | 1.7 |
| Power class | 400 V AC |
| Capacity [kW] | 1 |
| Output / Rated current [A] | 2.8 |
| Main circuit power supply input / Voltage/frequency*1 / AC input | 3-phase 380 V AC to 480 V AC, 50 Hz/60 Hz |
| Main circuit power supply input / Permissible voltage fluctuation / AC input | 3-phase 323 V AC to 528 V AC |
| Main circuit power supply input / Permissible frequency fluctuation | ±5 % maximum |
| Control circuit power supply input / Voltage/frequency / AC input | 1-phase 380 V AC to 480 V AC, 50 Hz/60 Hz |
| Control circuit power supply input / Rated current [A] | 0.1 |
| Control circuit power supply input / Permissible voltage fluctuation / AC input | 3-phase 323 V AC to 528 V AC |
| Control circuit power supply input / Permissible frequency fluctuation | ±5 % maximum |
| Control circuit power supply input / Power consumption [W] | 30 |
| Interface power supply | 24 V DC ± 10 % (required current capacity: 0.3 A (including CN8 connector signals)) |
| Permissible regenerative power / Built-in regenerative resistor [W]*2 *3 | 15 |
| Communication function | USB: Connect a personal computer (MR Configurator2 compatible) |
| A/B/Z-phase pulse output | Compatible |
| Analog monitor | 2 channels |
| Load-side encoder interface | Mitsubishi Electric high-speed serial communication, A/B/Z-phase differential input signal |
| Servo functions | Advanced vibration suppression control II, adaptive filter II, robust filter, auto tuning, one-touch tuning, tough drive function, drive recorder function, machine diagnosis function (including failure prediction*11), power monitoring function, scale measurement function, super trace control, lost motion compensation function |
| Protective functions | Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheat protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, error excessive protection, magnetic pole detection protection, linear servo control fault protection |
| Safety sub-function | STO (IEC/EN 61800-5-2) |
| Safety performance / Mean time to dangerous failure (MTTFd) | MTTFd ≥ 100 [years] (314a) |
| Safety performance / Diagnostic coverage (DC) | DC = Medium, 97.6 [%] |
| Safety performance / Probability of dangerous Failure per Hour (PFH) | PFH = 6.4 × 10-9 [1/h] |
| Satisfied standards | Refer to "Standards and certifications (by product) Products" for compliance with global standards and regulations. |
| Structure (IP rating) | Natural cooling, open (IP20) |
| Close mounting / 3-phase power supply input | Not possible |
| Environment / Ambient temperature / Operation | 0 °C to 55 °C (non-freezing) |
| Environment / Ambient temperature / Storage | -20 °C to 65 °C (non-freezing) |
| Environment / Ambient humidity | Operation/storage: 5 %RH to 90 %RH (non-condensing) |
| Listed / Power class [V] | 400 V AC |
| Listed / Capacity [kW] | 1 |
| Listed / Command interface | CC-Link IE Field Network |
| Main circuit power supply input / Rated current [A] | 2.5 |
| Dynamic brake*7 | Built-in |
| Command interface | CC-Link IE Field Network |
| Fully closed loop control | Two-wire/four-wire type communication method |
| Positioning mode*10 | Point table method, indexer method |
| Safety performance / Satisfied standards*12 | EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2 |
| Output / Rated voltage | 3-phase 323 V AC |
| Safety performance / Response performance | 8 ms or less (STO input OFF → energy shut-off) |
| Environment / Altitude | 2000 m or less above sea level*15 |
| Environment / Vibration resistance | 5.9 m/s2 at 10 Hz to 55 Hz (directions of X, Y, and Z axes) |
| Permissible regenerative power / External regenerative resistor (standard accessory) [W]*2 *3 *5 *6 | - |
| Command communication cycle*9 | 0.5 ms, 1.0 ms, 2.0 ms, 4.0 ms |
| Safety performance / Test pulse input (STO)*13 | Test pulse interval: 1 Hz to 25 Hz, test pulse off time: 1 ms maximum |
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر