Stratos MAXO-D 65/0,5-16 PN 6/10
رقم القطعة: wilo-2164659
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: wilo-2164659
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
Design Smart glandless twin-head circulator with screwed connection or flange connection, EC motor with integrated electronic power adjustment. Application Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems. Equipment/function Field of application The pump facilitates an operation with highest system efficiency via precise setting of the control mode for the system-specific application (e.g. radiator, underfloor heating, ceiling cooling). Heating - Radiator - Underfloor heating - Ceiling heating - Fan heater - Concrete core heating* - Hydraulic shunt - Differential pressure-less distributor* - Buffer heating* - Heat exchanger - Heat source circuit (heat pump)* - District heating loop* Cooling - Ceiling cooling - Underfloor cooling - Air-conditioning devices - Concrete core cooling* - Hydraulic shunt - Differential pressure-less distributor* - Buffer cooling* - Heat exchanger - Recooling circuit* - District cooling circuit* (* system types from SW≥01.05.10.00 available) Heating and cooling combined - Automatic switchover (version “-R7”: not possible; however, possible with Stratos MAXO temperature sensor) The following control modes are available depending on the selected application: Control modes - Constant speed (control mode) - Δp-c for constant differential pressure - Δp-v for variable differential pressure - Dynamic Adapt plus for continuous (dynamic) adjustment of the delivery rate to the current requirement - T-const. for constant temperature control - ΔT-const. for constant differential temperature control - Constant Q for constant volume flow control - Multi-Flow Adaptation: Total volume flow determination through the feeder pump for the needs-based supply of secondary pumps in the heating circuit distributors - User-defined PID control Optional functions - Q-Limitmax. for limiting the maximum volume flow - Q-Limitmin. for limiting the minimum volume flow - No-Flow Stop (zero-flow-deactivation) - Automatic night setback (version “-R7”: not possible; however, possible with Stratos MAXO temperature sensor - Index circuit evaluator (Δp-c control with external actual value sensor) - Thermal disinfection detection (Stratos MAXO-Z) - Variable pitch of Δp-v pump curve Manual settings - Selection of the field of application in the setting assistant - Setting the related operating parameters - Nominal duty point: direct input of calculated duty point at Δp-v - Status display - Setting and resetting the energy meters (heating and cooling) - Pump venting function - Key lock for disabling the settings - Function for resetting the factory settings or the saved restoration points (parameter sets) - Parameterising the analogue inputs - Parameterising the binary inputs - Parameterising the relay outputs - Dual-pump function (for 2 single pumps, which should be operated as a two-pump system) Automatic functions - Power adjustment according to requirements for energy-efficient operation depending on the operating mode - Detection of night setback (version “-R7”: not possible; however, possible with Stratos MAXO temperature sensor - Deactivation at zero flow (No-Flow Stop) - Soft start - Automatic troubleshooting routines (e.g. deblocking function) - Switchover between heating/cooling mode (version "-R7": automatic switchover not possible; however, possible with Stratos MAXO temperature sensor) - Full motor protection with integrated trip electronics External control inputs and their functions 2 x analogue inputs: - Signal types: 0 – 10 V, 2 – 10 V, 0 – 20 mA, 4 – 20 mA, PT1000 - Applications: Remote adjustment of the setpoints in every control mode (except Multi-Flow Adaptation), sensor inputs for temperature, differential pressure or free sensor in user-defined PID operation2 x digital inputs: - For potential-free control outputs or switch - Parametrisable functions: - Ext. Off - Ext. Min - Ext. Max - MANUAL (BMS-OFF) - Key lock - Switchover between…
Wilo
اطلب عرض سعر
Wilo
اطلب عرض سعر
Wilo
اطلب عرض سعر
Wilo
اطلب عرض سعر
Wilo
اطلب عرض سعر
Wilo
اطلب عرض سعر
Wilo
اطلب عرض سعر
Wilo
اطلب عرض سعر