Yonos GIGA2.0-I 150/1-13/7,5-S1
رقم القطعة: wilo-2234741
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: wilo-2234741
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
Design High energy efficiency in-line pump with IE5 motor (0.37 – 7.5 kW) or IE4 motor (11 – 22 kW) and electronic power adjustment in glanded pump design. Version as single-stage low-pressure centrifugal pump with flange connection and mechanical seal. Application The pumping of heating water (in accordance with VDI 2035), chilled water and water-glycol mixtures without abrasive substances in heating, chilled water and cooling systems. Equipment/function Control modes: - Δp-v for variable differential pressure - Δp-c for constant differential pressure - Constant speed - User-defined PID control Manual settings: - Setting the control mode - Setting the related operating parameters - Parameterising the analogue inputs - Parameterising the digital input - Parameterising the relay outputs - Dual-pump function (for 2 single pumps, which should be operated as a two-pump system) - Key lock for disabling the settings - Function for resetting to factory setting Automatic functions: - Power adjustment according to requirements for energy-efficient operation depending on the control mode - Automatic troubleshooting routines - Integrated full motor protection External control inputs and outputs and their functions - 1 x analogue input: - Signal types: 0 ... 10 V, 2 ... 10 V, 0 ... 20 mA, 4 ... 20 mA - Application: only sensor value from differential pressure sensor (installed serially on the pump as standard) - 1 x analogue input: - Signal types: 0 ... 10 V, 2 ... 10 V, 0 ... 20 mA, 4 ... 20 mA - Application: only external setpoint sensor - 1 x digital input: - Control input for “External OFF” function - 2x relay output: - Collective fault signal SSM (potential-free changeover contact) - Collective run signal SBM (potential-free changeover contact) - Wilo Net - For dual-pump management of 2 single pumps Signal and display functions - Display status of "Operation display": - Current control mode - Setpoint - Actual delivery head - Actual speed - Actual volume flow - Electrical power consumption - Status display LED: Faultless operation (green LED), pump communication (blue LED) - Display status of "Display fault" (display red): - Error codes - Display status of "Display warning" (display yellow): - Warning codes - Display status of "Process indicator" (display blue): - Display status of "Building automation (BA) communication" (display blue): - Summary of the active building automation (BA) parameters (baud rate, address, etc.) - Collective fault signal SSM (potential-free changeover contact) - Collective run signal SBM (potential-free changeover contact) Data exchange - Possible with accessories of corresponding Wilo-CIF modules: - Serial digital Modbus RTU interface for connection to building automation (BA) via RS485 bus system - Serial digital BACnet MS/TP interface for connection to building automation (BA) via RS485 bus system - Serial digital interface for Ethernet Multiprotocol Modbus TCP, BACnet/IP for connection to building automation (BA) via RJ45 bus system - Serial digital LON interface for connection to building automation (BA) via LONWorks bus system - Serial digital PLR interface for connection to BA via company-specific coupling module - Serial digital CANopen interface for connection to BA via company-specific coupling module Dual-pump management (twin-head pump or 2 x single pumps in Y-piece) - Main/standby operation (time-dependent pump alternation) - Main/standby operation (automatic fault-actuated switchover) - Parallel operation (efficiency-optimised peak load cut-in and out) Equipment - Pump hydraulics with minimum efficiency index MEI ≥ 0.4 - EC motor (0.37 – 7.5 kW) of efficiency class IE5 / AC motor (11 – 22 kW) of efficiency class IE4 in accordance with IEC 60034-30-2 - Flange PN 16 – according to EN 1092-2 - Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor) - Standard condensate drainage holes in the lantern and in the motor…

Wilo
اطلب عرض سعر

Wilo
اطلب عرض سعر

Wilo
اطلب عرض سعر

Wilo
اطلب عرض سعر

Wilo
اطلب عرض سعر

Wilo
اطلب عرض سعر

Wilo
اطلب عرض سعر

Wilo
اطلب عرض سعر