The Manual Call Point is commonly used to manually initiate a hazard alert. Resettable operating element 170° viewable LED Suitable for semi flush or surface mounting ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning XP95, Discovery and CoreProtocol compatible
| General / Warranty | 10 year |
|---|---|
| Mechanical / Product length | 90mm |
| Mechanical / Product width | 90mm |
| Mechanical / Product depth | 63mm |
| Mechanical / Product length (imperial) | 3.54in |
| Mechanical / Weight | 180g |
| Mechanical / Product width (imperial) | 3.54in |
| Mechanical / Product depth (imperial) | 2.48in |
| Mechanical / Colour | White |
| Mechanical / Materials housing | Polycarbonate |
| Environmental / Operating temperature (max) | 70°C |
| Environmental / Operating temperature (min) | -40°C |
| Environmental / Operating temperature | -40 to 70°C |
| Conformance / Standards | EN 54-11, EN 54-17 |
| Environmental / IP rating Value | IP44 |
| Electrical / Supply voltage (min) | 17V dc |
| Environmental / Operating temperature (imperial) | -40 to 158°F |
| Electrical / Supply voltage (max) | 35V dc |
| Environmental / Operating temperature (max) (imperial) | 158°F |
| Electrical / Supply voltage (Vmin-Vmax) | 17 to 35V dc |
| Environmental / Operating temperature (min) (imperial) | -40°F |
| Environmental / Humidity (max) | 95%, RH |
| Environmental / Humidity (min) | 0%, RH |
| Environmental / Humidity Note | no condensation or icing |
| Electrical / Protocol voltage | 5 to 13V peak to peak |
| Environmental / Humidity | 0% to 95% (no condensation or icing) |
| Electrical / Protocol voltage (max) | 13V |
| Electrical / Protocol voltage (min) | 5V |
| Electrical / Polarity | L1 &, L2 are polarity sensitive |
| Electrical / Power-up surge current | 1mA |
| Electrical / Quiescent current | 100μA |
| Electrical / Quiescent current tested at | 24V dc |
| Electrical / Maximum power-up time | 1 second |
| Electrical / Status indicator – Alarm | Red |
| Electrical / Status indicator – Fault | Yellow |
| Performance / Analogue value nominal | 16 |
| Performance / Alarm level analogue value | 64 |
| Mechanical / Key type | Apollo, Manal, Call, Point reset key |
| Electrical / Status indicator – Isolate | Yellow |
| Electrical / Status indicator – Poll | Flashing green |
| Performance / Fault level analogue value | 4 |
| Performance / Type | A |
| Performance / Operating element | Resettable element |
| Performance / Action | Single |
| Apollo Part Number | SA5900-903APO |
| Apollo Range | xp95 |
| Apollo Category | mcp |
Apollo Fire Detectors