601H-R / 601H-R-M / 611H-F / 631H-F Heat 601F
رقم القطعة: 516.600.006
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: 516.600.006
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
These detectors are capable of detecting the visible smoke produced by materials which smoulder or burn slowly, i.e. soft furnishings, plastic foam etc;. or ‘smoke’ produced by overheated but unburnt PVC. These detectors are particularly suitable for general applications and areas where cable overheating may occur e.g. electrical services areas. The novel design of the asymmetrical sampling chamber and signal processing techniques stop unwanted alarms caused by very small insects. i.e. thrips. Smoke entering the sampling chamber scatters the infra-red light pulses onto a photo-diode. These pulses are converted to an electrical signal which is compared against a preset alarm level. Flame detectors, unlike smoke and heat detectors, do not rely on convection to transport the fire product to the detector, nor do they rely on a ceiling to trap the products. They can therefore, be used to protect large open areas without sacrificing speed of response to flaming fires. In order to ensure full coverage, however, flame detectors do require direct line of sight to all parts of the protected area. Infra-red flame detectors such as the 601F are designed to respond rapidly to fires which involve cleanburning fuels such as alcohol or methane, ie fires which would not be detected by smoke detectors. The 601F Flame detector, by virtue of it’s operating wavelength and flicker discrimination, is insensitive to normal environmental influences. For outdoor use, a solarblind detector (e.g. the S200Plus) should be used. The 601F flame detector should, normally, only be used inside buildings to supplement heat and smoke detectors.
| ZETTLER Order Code | 516.600.006 |
|---|---|
| ZETTLER Category | Smoke, Heat & Multi-Sensor Detectors |
| ZETTLER Device Class | Detector |
| ZETTLER Model | 601F |
| ZETTLER Range | Conventional Detectors |
| Weight | 74 g (Excluding Base) |
| Operating Temp | -20°C to +70°C |
| Storage Temp | -25 to +80°C 90% RH continuous (non-condensing) and up |
| Voltage | 18-28Vdc |
| Colour | RAL9016 Traffic White* |
| Dimensions | Dia.109mm |
| Alarm current | 42 mA |
| Detector material | FR3010 Bayblend |
| Quiescent Current | 300μA |
| Should be Humidity | to 99% RH intermittent |
| when the detector is mounted in a roof void, lift shaft etc. — 540.003.006 | Remote Indication LED |
| when the detector is mounted in a roof void, lift shaft etc. — Dimensions (W x H x D) | 86 x 86 x 16 mm |
| when the detector is mounted in a roof void, lift shaft etc. — Operating Temperature | -20 to +70 °C |
| when the detector is mounted in a roof void, lift shaft etc. — Storage Temperature | -45 to +80 °C |
| when the detector is mounted in a roof void, lift shaft etc. — Relative Humidity | 95% (non condensing) |
| when the detector is mounted in a roof void, lift shaft etc. — Current consumption Standby | 0 Alarm: 5.43 mA 139 |