Eaton

Eaton E59 AccuProx analog inductive proximity sensor

رقم القطعة: 136212

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Eaton E59 AccuProx analog inductive proximity sensor

المواصفات

Ambient operating temperature - max70 °C
Ambient operating temperature - min-40 °C
FunctionsProtection against polarity reversal Short-circuit protection Protection against wire breakage
Number of contacts (normally closed contacts)1
Product NameEaton E59 AccuProx analog inductive proximity sensor
Catalog Number136212
Model CodeE59-M12C110D01-D2
EAN4015081330058
Product Length/Depth152.4 mm
Product Height44.45 mm
Product Width127 mm
Product Weight0.45 kg
CertificationsCertified by UL for use in Canada UL File No.: E166051 UL 508 IEC/EN 60947-5-2 UL UL Category Control No.: NRKH, NRKH7 CE CSA-C22.2 No. 14 CSA File No.: UL report applies to both US and Canada
Source URLhttps://www.eaton.com/gb/en-gb/skuPage.136212.html
TypeInductive sensor
Degree of protectionIP67 IP69 NEMA 4X, 6, 13
Enclosure materialMetal
Mounting methodNon-flush mounting
MaterialStainless steel
Shock resistance30 g, Mechanical, Shock duration 11 ms
Electric connection typeConnector M12
Product categoryiProx Series
Connection typePlug-in connection M12 x 1 3-wire
Enclosure typeCylinder, screw-thread
Voltage typeDC
Enclosure material finishingOther
Explosion safety category for dustNone
Explosion safety category for gasNone
Interface typeNone
LED indicatorStatus indication of Operating voltage: Green LED Status indication of Switching state: Red LED
Switch function typeBreaker contact
Load current1 - 300 mA (Ie)
Rated control supply voltage (Us) at DC - max48 V
Rated control supply voltage (Us) at DC - min6 V
Sensor length69 mm
Voltage rating - max48 V
Switching frequency300 Hz
Switching output typePNP
Number of contact energized outputs with signalling function0
Number of outputs (protected contact energized)0
Number of outputs (protected semiconductor)0
Number of outputs (semiconductor with signaling function)1
Diameter sensor12 mm
Supply voltage - max48 V
Supply voltage - min6 V
Installation typeNot flat
Operational current (Ib) in the switched state at 24 V DC15 A
Safety performance level (EN ISO 13849-1)None
SIL (IEC 61508)None
Actuation typeMetallic Target
Category (EN 954-1)B
Repeatability3 %
Switching hysteresis of Sn15 %
Voltage drop (Ud)2.5 V
Residual current0.15 mA (through the load in the blocked state at 230 V AC and 24 V DC)
Temperature drift of sn10 %
Rated switching distance (Sn) - max10 mm