| Ambient operating temperature - max | 60 °C |
|---|---|
| Ambient operating temperature - min | -25 °C |
| Climatic proofing | 25-55 °C / 90-95% relative humidity according to IEC 60068-2 |
| RAL-number | 7035 |
| Special features | Ambient temperature hint: Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °CTripping signal contact for subsequent installation Z-NHK 248434 |
| Product Name | Eaton Distribution parts |
| Catalog Number | 235869 |
| Model Code | PFR3-03-U |
| EAN | 4015082358693 |
| Product Length/Depth | 76 mm |
| Product Height | 80 mm |
| Product Width | 70 mm |
| Product Weight | 0.301 kg |
| Compliances | RoHS conform |
| Source URL | https://www.eaton.com/gb/en-gb/skuPage.235869.html |
| Used with | KLV-TC-4 276241 (Compact enclosure) Z-RC/AK-4TE 101062 (sealing cover set) Type U PFR3 Residual current relay KLV-TC-4 276241 (Compact enclosure) Z-RC/AK-4TE 101062 (sealing cover set) |
| Features | Selective protection Additional equipment possible Residual current relay |
| Type | PFR3Residual current relayType U |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Degree of protection | IP20, IP40 with suitable enclosure IP20 |
| Built-in depth | 69.5 mm |
| Color | Gray |
| Width in number of modular spacings | 4 |
| Mounting method | Quick attachment with 2 latch positions on top-hat rail IEC/EN 60715 DIN rail |
| Number of poles | Four-pole |
| Amperage Rating | 25 A |
| Rated operational voltage (Ue) - max | 400 V |
| Voltage rating | 230 V AC / 400 V AC |
| Terminal capacity (solid wire) | 1.5 mm² - 35 mm² |
| Terminal capacity (stranded cable) | 16 mm² (2x) |
| Rated operational current for specified heat dissipation (In) | 25 A |
| Frequency rating | 50 Hz |
| Pollution degree | 2 |
| Rated insulation voltage (Ui) | 440 V |
| Frame | 45 mm |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Lifespan, mechanical | 20000 operations |
| Voltage type | AC |
| Lifespan, electrical | 4000 operations |
| Connectable conductor cross section (multi-wired) - max | 16 mm² |
| Connectable conductor cross section (multi-wired) - min | 1.5 mm² |
| Connectable conductor cross section (solid-core) - max | 35 mm² |
| Connectable conductor cross section (solid-core) - min | 1.5 mm² |
| Accessories required | Z-HK 248432 |
| Heat dissipation per pole, current-dependent | 0 W |
| Heat dissipation capacity | 0 W |
| Terminal protection | Finger and hand touch safe, DGUV VS3, EN 50274 |
| Surge current capacity | 5 kA |
| Fault current rating | 300 mA |
| Leakage current type | A |
| Sensitivity type | Pulse-current sensitive |
| Rated short-time withstand current (Icw) | 10 kA |
| Built-in width (number of units) | 70 mm (4 SU) |
| Busbar material thickness | 0.8 mm - 2 mm |
| Terminals (top and bottom) | Twin-purpose terminals |
| Permitted storage and transport temperature - max | 60 °C |
| Permitted storage and transport temperature - min | -35 °C |
| Rated fault current - max | 0.3 A |
| Rated fault current - min | 0.3 A |
| Tripping time | 40 ms delayed - selective switch off |
| Rated short-circuit strength | 5 kA |
| Test circuit range | 184 V AC - 440 V AC |