Eaton

Eaton Distribution parts

رقم القطعة: 235870

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Eaton Distribution parts

المواصفات

Ambient operating temperature - max60 °C
Ambient operating temperature - min-25 °C
Climatic proofing25-55 °C / 90-95% relative humidity according to IEC 60068-2
RAL-number7035
Special featuresAmbient temperature hint: Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °CTripping signal contact for subsequent installation Z-NHK 248434
Product NameEaton Distribution parts
Catalog Number235870
Model CodePFR2-1-U
EAN4015082358709
Product Length/Depth76 mm
Product Height80 mm
Product Width70 mm
Product Weight0.296 kg
CompliancesRoHS conform
Source URLhttps://www.eaton.com/gb/en-gb/skuPage.235870.html
Used withKLV-TC-4 276241 (Compact enclosure) Z-RC/AK-4TE 101062 (sealing cover set) PFR2 Type U Residual current relay KLV-TC-4 276241 (Compact enclosure) Z-RC/AK-4TE 101062 (sealing cover set)
FeaturesResidual current relay Additional equipment possible Selective protection
TypePFR2Residual current relayType U
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Degree of protectionIP20 IP20, IP40 with suitable enclosure
Built-in depth69.5 mm
ColorGray
Width in number of modular spacings4
Mounting methodDIN rail Quick attachment with 2 latch positions on top-hat rail IEC/EN 60715
Number of polesFour-pole
Amperage Rating25 A
Rated operational voltage (Ue) - max400 V
Voltage rating230 V AC / 400 V AC
Terminal capacity (solid wire)1.5 mm² - 35 mm²
Terminal capacity (stranded cable)16 mm² (2x)
Rated operational current for specified heat dissipation (In)25 A
Frequency rating50 Hz
Pollution degree2
Rated insulation voltage (Ui)440 V
Frame45 mm
Rated impulse withstand voltage (Uimp)4 kV
Lifespan, mechanical20000 operations
Voltage typeAC
Lifespan, electrical4000 operations
Connectable conductor cross section (multi-wired) - max16 mm²
Connectable conductor cross section (multi-wired) - min1.5 mm²
Connectable conductor cross section (solid-core) - max35 mm²
Connectable conductor cross section (solid-core) - min1.5 mm²
Accessories requiredZ-HK 248432
Heat dissipation per pole, current-dependent0 W
Heat dissipation capacity0 W
Terminal protectionFinger and hand touch safe, DGUV VS3, EN 50274
Surge current capacity5 kA
Fault current rating1000 mA
Leakage current typeA
Sensitivity typePulse-current sensitive
Rated short-time withstand current (Icw)10 kA
Built-in width (number of units)70 mm (4 SU)
Busbar material thickness0.8 mm - 2 mm
Terminals (top and bottom)Twin-purpose terminals
Permitted storage and transport temperature - max60 °C
Permitted storage and transport temperature - min-35 °C
Rated fault current - max1 A
Rated fault current - min1 A
Tripping time40 ms delayed - selective switch off
Rated short-circuit strength5 kA
Test circuit range184 V AC - 440 V AC

منتجات مشابهة