Eaton

Eaton Moeller series xEffect - FAZ-PN MCB

رقم القطعة: 279149

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Eaton Moeller series xEffect - FAZ-PN MCB

المواصفات

Ambient operating temperature - max75 °C
Ambient operating temperature - min-25 °C
Product NameEaton Moeller series xEffect - FAZ-PN MCB
Catalog Number279149
Model CodeFAZ-PN-B16/1N
EAN4015082791490
Product Length/Depth80 mm
Product Height75.5 mm
Product Width17.5 mm
Product Weight0.114 kg
CompliancesRoHS conform
CertificationsIEC/EN 60898 EN45545-2 IEC 61373
Source URLhttps://www.eaton.com/gb/en-gb/skuPage.279149.html
Used withMiniature circuit breaker FAZ-PN
FeaturesConcurrently switching N-neutral Additional equipment possible
TypeFAZ-PNMiniature circuit breaker
10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistanceMeets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.
10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.
10.2.7 InscriptionsMeets the product standard's requirements.
10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distancesMeets the product standard's requirements.
10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.
10.8 Connections for external conductorsIs the panel builder's responsibility.
10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.
10.9.3 Impulse withstand voltageIs the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.
Degree of protectionIP20 IP40 (when fitted)
Built-in depth70.5 mm
Width in number of modular spacings1
Mounting methodTop-hat rail IEC/EN 60715
Number of polesSingle-pole + N
Amperage Rating16 A
Rated operational voltage (Ue) - max230 V
Voltage rating240 V AC / 415 V AC
Voltage rating at DC60 V DC (per pole)
Pollution degree2
Rated insulation voltage (Ui)440 V
Direction of incoming supplyAs required
Overvoltage categoryIII
Frame45 mm
Rated impulse withstand voltage (Uimp)4 kV
Voltage typeAC
Lifespan, electrical4000 operations
Connectable conductor cross section (multi-wired) - max25 mm²
Connectable conductor cross section (multi-wired) - min1 mm²
Connectable conductor cross section (solid-core) - max25 mm²
Connectable conductor cross section (solid-core) - min1 mm²
Mounting width17.5 mm
ApplicationSwitchgear for industrial and advanced commercial applicationsxEffect - Switchgear for industrial and advanced commercial applications
Terminal protectionFinger and hand touch safe, DGUV VS3, EN 50274
Enclosure width80 mm
Current limiting class3
Admissible back-up fuse - max100 A gL/gG
Frequency rating - max60 Hz
Frequency rating - min50 Hz
Tripping characteristicB
Number of poles (protected)1
Number of poles (total)2
Release characteristicB
Terminals (top and bottom)Twin-purpose terminals
Terminal capacity (control cable)16 mm² (1x)
Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 230 V10 kA
Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 400 V10 kA
Rated switching capacity (IEC/EN 60947-2)10 kA
Power loss2.6 W
Mounting width per pole17.5 mm
Rated short-circuit breaking capacity (IEC/EN 60898-1) - Icn at 230 V6 kA
Rated short-circuit breaking capacity (IEC/EN 60898-1)- Icn at 400 V6 kA
Selectivity class3