Eaton Moeller series xEffect - FAZ-PN MCB
رقم القطعة: 279153
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.

رقم القطعة: 279153
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
Eaton Moeller series xEffect - FAZ-PN MCB
| Ambient operating temperature - max | 75 °C |
|---|---|
| Ambient operating temperature - min | -25 °C |
| Product Name | Eaton Moeller series xEffect - FAZ-PN MCB |
| Catalog Number | 279153 |
| Model Code | FAZ-PN-B40/1N |
| EAN | 4015082791537 |
| Product Length/Depth | 80 mm |
| Product Height | 75.5 mm |
| Product Width | 17.5 mm |
| Product Weight | 0.124 kg |
| Compliances | RoHS conform |
| Certifications | IEC/EN 60898 EN45545-2 IEC 61373 |
| Source URL | https://www.eaton.com/gb/en-gb/skuPage.279153.html |
| Used with | Miniature circuit breaker FAZ-PN |
| Features | Concurrently switching N-neutral Additional equipment possible |
| Type | FAZ-PNMiniature circuit breaker |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Degree of protection | IP40 (when fitted) IP20 |
| Built-in depth | 70.5 mm |
| Width in number of modular spacings | 1 |
| Mounting method | Top-hat rail IEC/EN 60715 |
| Number of poles | Single-pole + N |
| Amperage Rating | 40 A |
| Rated operational voltage (Ue) - max | 230 V |
| Voltage rating | 240 V AC / 415 V AC |
| Voltage rating at DC | 60 V DC (per pole) |
| Pollution degree | 2 |
| Rated insulation voltage (Ui) | 440 V |
| Direction of incoming supply | As required |
| Overvoltage category | III |
| Frame | 45 mm |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Voltage type | AC |
| Lifespan, electrical | 4000 operations |
| Connectable conductor cross section (multi-wired) - max | 25 mm² |
| Connectable conductor cross section (multi-wired) - min | 1 mm² |
| Connectable conductor cross section (solid-core) - max | 25 mm² |
| Connectable conductor cross section (solid-core) - min | 1 mm² |
| Mounting width | 17.5 mm |
| Application | Switchgear for industrial and advanced commercial applicationsxEffect - Switchgear for industrial and advanced commercial applications |
| Terminal protection | Finger and hand touch safe, DGUV VS3, EN 50274 |
| Enclosure width | 80 mm |
| Current limiting class | 3 |
| Admissible back-up fuse - max | 100 A gL/gG |
| Frequency rating - max | 60 Hz |
| Frequency rating - min | 50 Hz |
| Tripping characteristic | B |
| Number of poles (protected) | 1 |
| Number of poles (total) | 2 |
| Release characteristic | B |
| Terminals (top and bottom) | Twin-purpose terminals |
| Terminal capacity (control cable) | 16 mm² (1x) |
| Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 230 V | 10 kA |
| Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 400 V | 10 kA |
| Rated switching capacity (IEC/EN 60947-2) | 10 kA |
| Power loss | 6.5 W |
| Mounting width per pole | 17.5 mm |
| Rated short-circuit breaking capacity (IEC/EN 60898-1) - Icn at 230 V | 6 kA |
| Rated short-circuit breaking capacity (IEC/EN 60898-1)- Icn at 400 V | 6 kA |
| Selectivity class | 3 |