Belden

New generation: interface converter electrical/optical for PROFIBUS-field bus networks; repeater fun

رقم القطعة: OZD Profi 12M G11-1300

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

New generation: interface converter electrical/optical for PROFIBUS-field bus networks; repeater function; for quartz glass FO; long-haul version; approval for Ex-zone 2 (Class 1, Div. 2)

المواصفات

TypeOZD Profi 12M G11-1300
NameOZD Profi 12M G11-1300
Operating temperature0-+60 °C
Minimum Storage Temperature-40-+70 °C
Weight560 g
Mount TypeDIN rail or mounting plate
Scope of deliverydevice, start-up instructions
Source URLhttps://www.belden.com/products/industrial-networking-cybersecurity/fiber-interfaces/fieldbus-repeaters/ozd-profi-12m-g11-1300
Belden Taxonomy Pathindustrial-networking-cybersecurity > fiber-interfaces > fieldbus-repeaters
Belden Categoryindustrial-networking-cybersecurity
Belden Subcategoryfiber-interfaces
Belden Sub-subcategoryfieldbus-repeaters
Datasheet URLhttps://catalog.belden.com/techdata/EN/OZDProfi12MG11-1300_techdata.pdf
Port Type and Quantity1 x optical: 2 sockets BFOC 2.5 (STR); 1 x electrical: Sub-D 9-pin, female, pin assignment according to EN 50170 part 1
Operating Voltage18 ... 32 VDC, typ. 24 VDC
Power Consumption4.5 W
Part Number (normalized)OZDProfi12MG11-1300
Multimode fiber (MM) 50/125 µm10000 m; 12 dB link budget at 1310 nm; A = 1 dB/km, 2 dB reserve
Multimode fiber (MM) 62.5/125 µm10000 m; 12 dB link budget at 1310 nm; A = 1 dB/km, 2 dB reserve
Relative humidity (non-condensing)10-95 %
IP Protection RatingIP40
Safety of industrial control equipmentcUL61010-2-201
Housing Materialdie-cast zink
Dimensions (WxHxD)39.5 x 137.5 x 84 mm
Guarantee60 months (please refer to the " https://assets.belden.com/m/1424ddb7a3280e7a/original/Hirschmann-Automation-and-Control-GmbH-Terms-of-Guarantee.pdf ">"terms of guarantee or detailed information)
Current consumptionmax. 190 mA
Basis StandardEU Conformity, FCC Conformity, AUS Conformity Australia
MTBF (Telcordia SR-332 Issue 3) @ 25°C2 978 997 h
Hazardous locationsISA 12.12.01 Class 1 Div. 2, ATEX Zone 2
Single mode fiber (SM) 9/125 µm15000 m; 10 dB link budget at 1310 nm; A = 0.5 dB/km, 2 dB reserve
Power Supply8-pin terminal block, screw mounting
Signal TypePROFIBUS (DP-V0, DP-V1, DP-V2 und FMS)
Measuring outputs "Optical input power"8-pin terminal block, screw mounting
Signaling contact8-pin terminal block, screw mounting
Multimode fiber HCS (MM) 200/230 µm-
Multimode fiber POF (MM) 980/1000 µm-
Input voltage range-7 V ... +12 V
Redundancy functionsredundant 24 V infeed
Output voltage/output current (pin6)5 VDC +5%, -10%, short circuit-proof/10 mA