المواصفات

TypeOCTOPUS 5TX EEC
DescriptionThe OCTOPUS switches are suited for outdoor applications with rough environmental conditions. Because of the branch typical approvals they can be used in transport applications (E1), as well as in trains (EN 50155) and ships (GL).
Operating temperature-40-+60 °C
Minimum Storage Temperature-40-+85 °C
Weight210 g
Mount TypeWall mounting
Scope of delivery1 × Device, 1 x connector for power connection, General safety instructions
Update and RevisionRevision Number: 0.97 Revision Date: 03-03-2026
Source URLhttps://www.belden.com/products/industrial-networking-cybersecurity/unmanaged-switches/ip67-rated/octopus-5tx-eec
Belden Taxonomy Pathindustrial-networking-cybersecurity > unmanaged-switches > ip67-rated
Belden Categoryindustrial-networking-cybersecurity
Belden Subcategoryunmanaged-switches
Belden Sub-subcategoryip67-rated
Datasheet URLhttps://catalog.belden.com/techdata/EN/OCTOPUS-5TXEEC_techdata.pdf
Port Type and Quantity5 ports in total uplink ports: 10/100 BASE-TX, M12 "D"-coding, 4-pole 5 x 10/100 BASE-TX TP-cable, auto-crossing, auto-negotiation, auto-polarity.
Operating Voltage12 V DC to 24 V DC (min. 9.0 V DC to max. 32 V DC)
Power Consumption2.4 W
Part Number (normalized)OCTOPUS-5TXEEC
Twisted pair (TP)0-100 m
IP Protection RatingIP67
Safety of industrial control equipmentcUL 508
Accessories to Order SeparatelyM12 conector, "D"-coded (934 445-001) 2 m cordset with M12-connector, "D"-coded (934 578-001) 5 m cordset with M12-connectors, "D"-coded (934 578-002) 10 m cordset with M12-connectors, "D"-coded (934 578-003) Bulkhead M12 "D"-coded to RJ45 (934 498-001) OCTOPUS dust cover set (25 pieces) (942 057-001),
NotePlease note that some recommended accessory parts only support a temperature range from -25 ºC to +70 ºC and might limit the possible operating conditions for the entire system.
EN 61000-4-2 Electrostatic Discharge (ESD)6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 Electromagnetic Field10 V/m (80-1000 MHz)
EN 61000-4-4 Fast Transients (Burst)2 kV power line, 2 kV data line
EN 61000-4-5 Surge Voltagepower line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 Conducted immunity3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
DiagnosticsLEDs (power, link status, data)
Dimensions (WxHxD)60 mm x 126 mm x 31 mm
IEC 60068-2-6 vibration1 mm, 2 Hz-13.2 Hz, 90 min. 0.7 g, 13.2 Hz-100 Hz, 90 min. 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min. 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock15 g, 11 ms duration, 18 shocks
EN 55032EN 55032 Class A
TransportationE1
Guarantee60 months (please refer to the " https://assets.belden.com/m/1424ddb7a3280e7a/original/Hirschmann-Automation-and-Control-GmbH-Terms-of-Guarantee.pdf ">"terms of guarantee or detailed information)
Product Documentationhttps://www.doc.hirschmann.com
Certificateshttps://www.doc.hirschmann.com/certificates.html
Power output in BTU (IT)/h8.2
FCC CFR47 Part 15FCC 47CFR Part 15, Class A
Basis StandardCE, EAC, Australian Regulatory Compliance Mark (RCM)
Software Downloadhttps://my.belden.com/s/downloads
Power supply/signaling contact1 x M12 5-pin connector, A coding, no signaling contact
Relative humidity (also condensing)5-100 %
Line - / star topologyany