Mitsubishi Electric

Q06UDVCPU - Number of I/O points: 4096, number of I/O device points: 8192, program capacity: 60K…

رقم القطعة: Q06UDVCPU_3885

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Q06UDVCPU - Number of I/O points: 4096, number of I/O device points: 8192, program capacity: 60K…

المواصفات

Basic information / Model nameQ06UDVCPU
Basic information / OverviewNumber of I/O points: 4096, number of I/O device points: 8192, program capacity: 60K steps, basic operation processing speed (LD X0): 1.9 ns, program memory capacity: 240K bytes, multi-CPU high-speed communication, external interface: USB/Ethernet, with memory card interface
Basic information / Sales statusOn sale
Listed / Model nameQ06UDVCPU
Weight0.20 kg
Basic information / Conformance standardUL cUL CE(EMC) CE(RoHS) KC(EMC) LR NK DNV ABS RINA BV
Shock resistanceCompliant with JIS B 3502 and IEC 61131-2 (147 m/s2, 3 times each in 3 directions X, Y, Z)
Operating atmosphereNo corrosive gases
Operating altitude0...2000 m
Installation locationInside a control panel
Overvoltage categoryII or less
Pollution degree2 or less
Operating ambient temperature0...55 ˚C
Storage ambient temperature-25...75 ˚C (The storage ambient temperature is -20 to 75 ˚C if the system includes the AnS/A Series modules.)
Operating ambient humidity5...95 %RH, non-condensing (The operating ambient humidity and storage ambient humidity are 10 to 90 %RH if the system includes the AnS/A Series modules.)
Storage ambient humidity5...95 %RH, non-condensing (The operating ambient humidity and storage ambient humidity are 10 to 90 %RH if the system includes the AnS/A Series modules.)
I/O control modeRefresh mode (The direct access input/output is available by specifying the direct access input/output (DX, DY).)
Number of I/O points4096 points (X/Y0...FFF)
Control methodStored program cyclic operation
Listed / OutlineNumber of I/O points: 4096, number of I/O device points: 8192, program capacity: 60K steps, basic operation processing speed (LD X0): 1.9 ns, program memory capacity: 240K bytes, multi-CPU high-speed communication, external interface: USB/Ethernet, with memory card interface
Allowable momentary power failure timeThe time differs depending on the power supply module used.
Clock functionYear, month, date, hour, minute, second, and day of week (automatic leap year detection) Accuracy: -2.97...+3.75 s (TYP. +0.39 s)/d at 0 ˚C Accuracy: -2.97...+3.75 s (TYP. +0.39 s)/d at 25 ˚C Accuracy: -12.77...+2.13 s (TYP. -5.32 s)/d at 55 ˚C
Constant scan0.5...2000 ms (setting is available in increments of 0.1 ms by parameter)
Programming language / Sequence control languageRelay symbol language, logic symbolic language, MELSAP3 (SFC), MELSAP-L, function block and structured text (ST)
Processing speed / Sequence instruction / LD X01.9 ns
Processing speed / Sequence instruction / MOV D0 D13.9 ns
Program capacity60K steps (240K bytes)
Memory capacity / Program memory (drive 0)240K bytes
Memory capacity / Standard ROM (drive 4)1025.5K bytes
Maximum number of storable files / Program memory124
Maximum number of storable files / Standard RAM323
Maximum number of storable files / Standard ROM256
Maximum number of intelligent function module parameters / Initial setting4096 parameters
Maximum number of intelligent function module parameters / Refresh2048 parameters
Number of I/O device points8192 points (X/Y0...1FFF)
No. of device points / Internal relay (M)15360 points (M0...15359) by default (changeable)
No. of device points / Latch relay (L)8192 points (L0...8191) by default (changeable)
No. of device points / Link relay (B)8192 points (B0...1FFF) by default (changeable)
No. of device points / Timer (T)2048 points (T0...2047) by default (changeable) (Low-speed and high-speed timers available) Low-speed or high-speed is specified by an instruction. The measurement unit is set by parameter. (Low-speed timer: 1...1000 ms (in increments of 1 ms), default: 100 ms) (High-speed timer: 0.01...100 ms (in increments of 0.01 ms), default: 10.0 ms)
No. of device points / Retentive timer (ST)0 points by default (changeable) (Low-speed and high-speed retentive timers available) Low-speed or high-speed is specified by an instruction. The measurement unit is set by parameter. (Low-speed retentive timer: 1...1000 ms (in increments of 1 ms), default: 100 ms) (High-speed retentive timer: 0.01...100 ms (in increments of 0.01 ms), default: 10.0 ms)
No. of device points / Counter (C)Normal counter: 1024 points (C0...1023) by default (changeable)
No. of device points / Data register (D)22528 points (D0...22527) by default (changeable)
No. of device points / Extended data register (D)0 points by default (changeable)
No. of device points / Link register (W)8192 points (W0...1FFF) by default (changeable)
No. of device points / Extended link register (W)0 points by default (changeable)
No. of device points / Annunciator (F)2048 points (F0...2047) by default (changeable)
No. of device points / Edge relay (V)2048 points (V0...2047) by default (changeable)
No. of device points / Link special relay (SB)2048 points (SB0...7FF) by default (changeable)
No. of device points / Link special register (SW)2048 points (SW0...7FF) by default (changeable)
No. of device points / Step relay (S)8192 points (S0...8191) by default (changeable)
No. of device points / Index register/standard device register (Z)20 points (Z0...19) (maximum)
No. of device points / Index register (Z) (32-bit index modification of ZR device)10 points (Z0...18) (maximum) (The index register is used as a double-word device.)
No. of device points / Pointer (P)4096 points (P0...4095) (The number of device points is fixed.) (The local pointer range and the common pointer range can be set by parameter.)
No. of device points / Interrupt pointer (I)256 points (I0...255) (The number of device points is fixed.) (The fixed scan interval for the system interrupt pointer I28 to 31 can be set by parameter.) 0.5...1000.0 ms (in increments of 0.5 ms) Default I28: 100 ms, I29: 40 ms, I30: 20 ms, I31: 10 ms
No. of device points / Special relay (SM)2048 points (SM0...2047) (The number of device points is fixed.)
No. of device points / Special register (SD)2048 points (SD0...2047) (The number of device points is fixed.)
No. of device points / Function input (FX)16 points (FX0...F) (The number of device points is fixed.)
No. of device points / Function output (FY)16 points (FY0...F) (The number of device points is fixed.)
No. of device points / Function register (FD)5 points (FD0...4) (The number of device points is fixed.)
Link direct deviceDevice that directly accesses the link device of a network module Specification format: J□□\X□□, J□□\Y□□, J□□\SB□□, J□□\W□□, J□□\SW□□
Intelligent function module deviceDevice that directly accesses the buffer memory of an intelligent function module Specified form: U...\G...
Latch (data retention during power failure) range8192 points (L0...8191) by default (The latch range can be set for the devices, B, F, V, T, ST, C, D, and W.)
Internal current consumption (5 V DC)0.58 A (only CPU module), 0.6 A (with an extended SRAM cassette)
External dimensions / Height98 mm
External dimensions / Width27.4 mm
External dimensions / Depth115 mm
Transmission specifications / Data transmission speed100/10 Mbps
Transmission specifications / Communication modeFull-duplex/Half-duplex
Transmission specifications / Transmission methodBase band
Transmission specifications / Maximum distance between hub and node100 m
Number of connectionsTotal of 16 for Socket communications, MELSOFT connections, and MC protocols. 1 for FTP.
Vibration resistance / Compliant with .. d IEC 61131-2 / Under intermittent vibration ~62dc24Frequency: 5...8.4 Hz, Half amplitude: 3.5 mm Frequency: 8.4...150 Hz, Constant acceleration: 9.8 m/s2 Sweep count: 10 times each in X, Y, Z directions
Vibration resistance / Compliant with .. and IEC 61131-2 / Under continuous vibration ~d68864Frequency: 5...8.4 Hz, Half amplitude: 1.75 mm Frequency: 8.4...150 Hz, Constant acceleration: 4.9 m/s2
Equipment classClass I
Listed / Large categoriesProgrammable controller CPU
Listed / Medium categoriesUniversal model
Listed / Small categoriesHigh-speed type
Memory capacity / Memory card (SD) (drive 2)Depends on the SD memory card (SD or SDHC type) used. (Max. 32G bytes)
Memory capacity / Standard RAM (drive 3) / Without an extended SRAM cassette768K bytes
Memory capacity / Standard RAM (drive 3) / With an extended SRAM cassetteCapacities of the memory in the module + extended SRAM cassette (The maximum capacity of an extended SRAM cassettes is 8M bytes.)
Memory capacity / CPU shared memory / QCPU standard memory8K bytes
Memory capacity / CPU shared memory / Multiple CPU high speed transmission area32K bytes
Maximum number of storable files / Memory card (SD) / SDRoot directory: 512 (maximum) Subdirectory: 65534 (maximum)
Maximum number of storable files / Memory card (SD) / SDHCRoot directory: 65535 (maximum) Subdirectory: 65534 (maximum)
No. of device points / File register (R) / Without an extended SRAM cassette32768 points (R0...32767) (Maximum 393216 points are available by switching blocks.)
No. of device points / File register (R) / With Q4MCA-1MBS32768 points (R0...32767) (Maximum 917504 points are available by switching blocks.)
No. of device points / File register (R) / With Q4MCA-2MBS32768 points (R0...32767) (Maximum 1441792 points are available by switching blocks.)
No. of device points / File register (R) / With Q4MCA-4MBS32768 points (R0...32767) (Maximum 2490368 points are available by switching blocks.)
No. of device points / File register (R) / With Q4MCA-8MBS32768 points (R0...32767) (Maximum 4587520 points are available by switching blocks.)
No. of device points / File register (ZR) / Without an extended SRAM cassette393216 points (ZR0...393215) (Blocks do not need to be switched.)
No. of device points / File register (ZR) / With Q4MCA-1MBS917504 points (ZR0...917503) (Blocks do not need to be switched.)
No. of device points / File register (ZR) / With Q4MCA-2MBS1441792 points (ZR0...1441791) (Blocks do not need to be switched.)
No. of device points / File register (ZR) / With Q4MCA-4MBS2490368 points (ZR0...2490367) (Blocks do not need to be switched.)
No. of device points / File register (ZR) / With Q4MCA-8MBS4587520 points (ZR0...4587519) (Blocks do not need to be switched.)
RUN/PAUSE contactOne contact can be set up in X0 to X1FFF for each of RUN and PAUSE.