| Basic information / Model name | Q00CPU |
|---|---|
| Basic information / Overview | Number of I/O points: 1024, number of I/O device points: 2048, program capacity: 8K steps, basic operation processing speed (LD X0): 160 ns, program memory capacity: 94K bytes, external interface: RS-232, without memory card interface |
| Basic information / Sales status | Discontinued |
| Listed / Model name | Q00CPU 2018/09 Discontinued |
| Weight | 0.13 kg |
| Basic information / Conformance standard | UL cUL CE(EMC) CE(RoHS) KC(EMC) LR NK DNV ABS RINA BV |
| Basic information / Discontinued date | 2018/09*Please check or inquire it in each overseas sales company site because the sale situation is different depending on each countries. |
| Basic information / Replacement models | Q00UCPU Learn more about our products R00CPU Learn more about our products Compare replacement models and specifications |
| Shock resistance | Compliant with JIS B 3502 and IEC 61131-2 (147 m/s2, 3 times each in 3 directions X, Y, Z) |
| Operating atmosphere | No corrosive gases |
| Operating altitude | 0...2000 m |
| Installation location | Inside a control panel |
| Overvoltage category | II or less |
| Pollution degree | 2 or less |
| Operating ambient temperature | 0...55 ˚C |
| Storage ambient temperature | -25...75 ˚C |
| Operating ambient humidity | 5...95 %RH, non-condensing |
| Storage ambient humidity | 5...95 %RH, non-condensing |
| I/O control mode | Refresh mode (The direct access input/output is available by specifying the direct access input/output (DX, DY).) |
| Number of I/O points | 1024 points (X/Y0...3FF) |
| Control method | Stored program cyclic operation |
| Listed / Outline | Number of I/O points: 1024, number of I/O device points: 2048, program capacity: 8K steps, basic operation processing speed (LD X0): 160 ns, program memory capacity: 94K bytes, external interface: RS-232, without memory card interface |
| Allowable momentary power failure time | The time differs depending on the power supply module used. |
| Clock function | Year, month, date, hour, minute, second, and day of week (automatic leap year detection) Accuracy: -3.20...+5.27 s (TYP. +1.98 s)/d at 0 ˚C Accuracy: -2.57...+5.27 s (TYP. +2.22 s)/d at 25 ˚C Accuracy: -11.68...+3.65 s (TYP. -2.64 s)/d at 55 ˚C |
| Constant scan | 1...2000 ms (setting is available in increments of 1 ms by parameter) |
| Programming language / Sequence control language | Relay symbol language, logic symbolic language, MELSAP3 (SFC), MELSAP-L, function block and structured text (ST) |
| Processing speed / Sequence instruction / LD X0 | 160 ns |
| Processing speed / Sequence instruction / MOV D0 D1 | 560 ns |
| Program capacity | 8K steps (32K bytes) |
| Memory capacity / Program memory (drive 0) | 94K bytes |
| Memory capacity / Standard RAM (drive 3) | 128K bytes |
| Memory capacity / Standard ROM (drive 4) | 94K bytes |
| Maximum number of storable files / Program memory | 6 |
| Maximum number of storable files / Standard RAM | 1 |
| Maximum number of storable files / Standard ROM | 6 |
| Maximum number of intelligent function module parameters / Initial setting | 512 parameters |
| Maximum number of intelligent function module parameters / Refresh | 256 parameters |
| Number of I/O device points | 2048 points (X/Y0...7FF) |
| No. of device points / Internal relay (M) | 8192 points (M0...8191) by default (changeable) |
| No. of device points / Latch relay (L) | 2048 points (L0...2047) by default (changeable) |
| No. of device points / Link relay (B) | 2048 points (B0...7FF) by default (changeable) |
| No. of device points / Timer (T) | 512 points (T0...511) by default (changeable) (Low-speed and high-speed timers available) Low-speed or high-speed is specified by an instruction. The measurement unit is set by parameter. (Low-speed timer: 1...1000 ms (in increments of 1 ms), default: 100 ms) (High-speed timer: 0.1...100.0 ms (in increments of 0.1 ms), default: 10.0 ms) |
| No. of device points / Retentive timer (ST) | 0 points by default (changeable) (Low-speed and high-speed retentive timers available) Low-speed or high-speed is specified by an instruction. The measurement unit is set by parameter. (Low-speed retentive timer: 1...1000 ms (in increments of 1 ms), default: 100 ms) (High-speed retentive timer: 0.1...100.0 ms (in increments of 0.1 ms), default: 10.0 ms) |
| No. of device points / Counter (C) | Normal counter: 512 points (C0...511) by default (changeable) Interrupt counter: 128 points max. (0 points by default, setting by parameters) |
| No. of device points / Data register (D) | 11136 points (D0...11135) by default (changeable) |
| No. of device points / Link register (W) | 2048 points (W0...7FF) by default (changeable) |
| No. of device points / Annunciator (F) | 1024 points (F0...1023) by default (changeable) |
| No. of device points / Edge relay (V) | 1024 points (V0...1023) by default (changeable) |
| No. of device points / File register (R) / Standard RAM | 32768 points (R0...32767) (Maximum 65536 points are available by switching blocks.) |
| No. of device points / File register (ZR) / Standard RAM | 65536 points (ZR0...65535) (Blocks do not need to be switched.) |
| No. of device points / Link special relay (SB) | 1024 points (SB0...3FF) (The number of device points is fixed.) |
| No. of device points / Link special register (SW) | 1024 points (SW0...3FF) (The number of device points is fixed.) |
| No. of device points / Step relay (S) | 2048 points (S0...127/block) (The number of device points is fixed.) |
| No. of device points / Pointer (P) | 300 points (P0...299) (The number of device points is fixed.) |
| No. of device points / Interrupt pointer (I) | 128 points (I0...127) (The number of device points is fixed.) (The fixed scan interval for the system interrupt pointer I28 to 31 can be set by parameter.) 2...1000 ms (in increments of 1 ms) Default I28: 100 ms, I29: 40 ms, I30: 20 ms, I31: 10 ms |
| No. of device points / Special relay (SM) | 1024 points (SM0...1023) (The number of device points is fixed.) |
| No. of device points / Special register (SD) | 1024 points (SD0...1023) (The number of device points is fixed.) |
| No. of device points / Function input (FX) | 16 points (FX0...F) (The number of device points is fixed.) |
| No. of device points / Function output (FY) | 16 points (FY0...F) (The number of device points is fixed.) |
| No. of device points / Function register (FD) | 5 points (FD0...4) (The number of device points is fixed.) |
| Link direct device | Device that directly accesses the link device of a network module Specification format: J□□\X□□, J□□\Y□□, J□□\SB□□, J□□\W□□, J□□\SW□□ |
| Intelligent function module device | Device that directly accesses the buffer memory of an intelligent function module Specified form: U...\G... |
| Latch (data retention during power failure) range | 2048 points (L0...2047) by default (The latch range can be set for the devices, B, F, V, T, ST, C, D, and W.) |
| Internal current consumption (5 V DC) | 0.25 A |
| External dimensions / Height | 98 mm |
| External dimensions / Width | 27.4 mm |
| External dimensions / Depth | 89.3 mm |
| Vibration resistance / Compliant with .. d IEC 61131-2 / Under intermittent vibration ~62dc24 | Frequency: 5...8.4 Hz, Half amplitude: 3.5 mm Frequency: 8.4...150 Hz, Constant acceleration: 9.8 m/s2 Sweep count: 10 times each in X, Y, Z directions |
| Vibration resistance / Compliant with .. and IEC 61131-2 / Under continuous vibration ~d68864 | Frequency: 5...8.4 Hz, Half amplitude: 1.75 mm Frequency: 8.4...150 Hz, Constant acceleration: 4.9 m/s2 |
| Equipment class | Class I |
| Listed / Large categories | Programmable controller CPU |
| Listed / Medium categories | Basic model |
| Memory capacity / CPU shared memory / QCPU standard memory | 1K bytes |
| RUN/PAUSE contact | One contact can be set up in X0 to X7FF for each of RUN and PAUSE. |
| No. of device points / Index register (Z) | 10 points (Z0...9) (The number of device points is fixed.) |