MR-J4-DU900B4-RJ - SSCNET III/H-compatible drive unit, 9 kW, 3-phase 380 V AC to 480 V AC
رقم القطعة: MR-J4-DU900B4-RJ_6485
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: MR-J4-DU900B4-RJ_6485
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
MR-J4-DU900B4-RJ - SSCNET III/H-compatible drive unit, 9 kW, 3-phase 380 V AC to 480 V AC
| Series | MELSERVO-J4 series |
|---|---|
| Model name | MR-J4-DU900B4-RJ |
| Basic information / Model name | MR-J4-DU900B4-RJ |
| Basic information / Overview | SSCNET III/H-compatible drive unit, 9 kW, 3-phase 380 V AC to 480 V AC |
| Basic information / Sales status | On sale |
| Listed / Series | MELSERVO-J4 series |
| Listed / Model name | MR-J4-DU900B4-RJ |
| Basic information / Conformance standard | UL CSA CE(EMC) CE(LVD) CE(Machinery) CE(RoHS) UKCA ChinaRoHS KC(EMC) |
| Environment / Ambience | Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust |
| Control method | Sine-wave PWM control/current control method |
| Mass [kg] ~81ac87 | 9.9 |
| Power class | 400 V AC |
| Capacity [kW] | 9 |
| Output / Rated current [A] | 25 |
| Control circuit power supply input / Voltage/frequency / AC input | 1-phase 380 V AC to 480 V AC, 50 Hz/60 Hz |
| Control circuit power supply input / Rated current [A] | 0.2 |
| Control circuit power supply input / Permissible voltage fluctuation / AC input | 1-phase 323 V AC to 528 V AC |
| Control circuit power supply input / Permissible frequency fluctuation | ±5 % maximum |
| Control circuit power supply input / Power consumption [W] | 45 |
| Interface power supply | 24 V DC ± 10 % (required current capacity: 0.3 A (including CN8 connector signals)) |
| Communication function | USB: Connect a personal computer (MR Configurator2 compatible) |
| A/B/Z-phase pulse output | Compatible |
| Analog monitor | 2 channels |
| Load-side encoder interface | Mitsubishi Electric high-speed serial communication, A/B/Z-phase differential input signal |
| Servo functions | Advanced vibration suppression control II, adaptive filter II, robust filter, auto tuning, one-touch tuning, tough drive function, drive recorder function, tightening & press-fit control, machine diagnosis function, power monitoring function, driver communication function, scale measurement function, J3 compatibility mode, super trace control, lost motion compensation function |
| Protective functions | Overcurrent shut-off, overload shut-off (electronic thermal), servo motor overheat protection, encoder error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, error excessive protection, magnetic pole detection protection, linear servo control fault protection |
| Safety sub-function | STO (IEC/EN 61800-5-2) |
| Safety performance / Mean time to dangerous failure (MTTFd) | MTTFd ≥ 100 [years] (314a) |
| Safety performance / Diagnostic coverage (DC) | DC = Medium, 97.6 [%] |
| Safety performance / Probability of dangerous Failure per Hour (PFH) | PFH = 6.4 × 10-9 [1/h] |
| Satisfied standards | Refer to "Standards and certifications (by product) Products" for compliance with global standards and regulations. |
| Structure (IP rating) | Force cooling, open (IP20)*6 |
| Close mounting / 3-phase power supply input | Not possible |
| Environment / Ambient temperature / Operation | 0 °C to 55 °C (non-freezing) |
| Environment / Ambient temperature / Storage | -20 °C to 65 °C (non-freezing) |
| Environment / Ambient humidity | Operation/storage: 5 %RH to 90 %RH (non-condensing) |
| Listed / Power class [V] | 400 V AC |
| Listed / Capacity [kW] | 9 |
| Listed / Command interface | SSCNET III/H |
| Command interface | SSCNET III/H |
| Compatible converter unit model | MR-CV18K4 |
| Main circuit power supply input | Main circuit power is supplied from the power regeneration converter unit/resistance regeneration converter unit to the drive unit. |
| Fully closed loop control | Two-wire/four-wire type communication method |
| Output / Rated voltage | 3-phase 323 V AC |
| Safety performance / Response performance | 8 ms or less (STO input OFF → energy shut-off) |
| Environment / Altitude | 2000 m or less above sea level*7 |
| Environment / Vibration resistance | 5.9 m/s2 at 10 Hz to 55 Hz (directions of X, Y, and Z axes) |
| Dynamic brake*1 | External option*2 |
| Command communication cycle*3 | 0.222 ms, 0.444 ms, 0.888 ms |
| Safety performance / Satisfied standards*4 | EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2 |
| Safety performance / Test pulse input (STO)*5 | Test pulse interval: 1 Hz to 25 Hz, test pulse off time: 1 ms maximum |