FX5-80SSC-G - Maximum number of control axes: 8 axes, CC-Link IE TSN connection, Positioning…
رقم القطعة: FX5-80SSC-G_11
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: FX5-80SSC-G_11
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
FX5-80SSC-G - Maximum number of control axes: 8 axes, CC-Link IE TSN connection, Positioning…
| Basic information / Model name | FX5-80SSC-G |
|---|---|
| Basic information / Overview | Maximum number of control axes: 8 axes, CC-Link IE TSN connection, Positioning control, synchronous control, speed control, torque control |
| Basic information / Sales status | On sale |
| Listed / Series | MELSEC iQ-F series |
| Listed / Model name | FX5-80SSC-G |
| Basic information / Conformance standard | UL cUL CE(EMC) CE(RoHS) KC(EMC) |
| Interpolation function | Linear interpolation (up to 4 axes), 2-axis circular interpolation |
| Control method | Positioning control, speed control, speed-torque control, speed-position switching control, fixed-pitch feed, synchronous control, cam control, continuous path control, position-speed switching control |
| Compensation function | Backlash compensation, electronic gear, near pass function |
| Manual control | JOG operation, inching operation, manual pulse generator operation (up to 1 module) |
| Number of control axes | Up to 8 axes |
| Operation cycle (operation cycle settings)*1 | 500 μs, 1000 μs, 2000 μs, 4000 μs |
| Acceleration/deceleration processing | Trapezoidal acceleration/deceleration, S-curve acceleration/deceleration |
| Synchronous control | Synchronous encoder input, command generation axis, cam, phase compensation, cam auto-generation |
| Control unit | mm, inch, degree, pulse |
| Positioning control method | Motion profile table |
| Number of positioning data | 600 data (positioning data No. 1 to 600)/axis (Can be set with MELSOFT GX Works3 or a sequence program.) |
| CC-Link IE TSN Class | B |
| Backup | Parameters, positioning data, and block start data can be saved on flash ROM (batteryless backup) |
| Home position return | Driver home position return*2 |
| Positioning control | Linear interpolation control (up to 4 axes)*3, fixed-pitch feed control (up to 4 axes), 2-axis circular interpolation (auxiliary point-specified, central point-specified), speed control (up to 4 axes), speed-position switching control (INC mode, ABS mode), position-speed switching control (INC mode), current value change, NOP instruction, JUMP instruction, LOOP, LEND, block start, condition start, wait start, simultaneous start, repeated start |
| Speed-torque control | Speed control not including position loop, torque control, continuous operation to torque control |
| Absolute position system | Provided (The servo motors are equipped with a batteryless absolute position encoder as standard.) |
| Synchronous encoder operation function | Up to 4 modules (via a CPU or a servo amplifier) |
| Speed limit | Speed limit value, JOG speed limit value |
| Torque limit function | Torque limit value same setting, torque limit value individual setting |
| Forced stop | Via buffer memory, valid/invalid setting |
| Software stroke limit function | Movable range check with feed current value or with machine feed value |
| Hardware stroke limit function | Provided |
| Speed change | Provided |
| Acceleration/deceleration processing change | Acceleration/deceleration time |
| Torque limit value change | Provided |
| Target position change function | Speed to a target position address and a target position is changeable. |
| Override | 0 to 300 % |
| M-code output function | Provided |
| Step function | Deceleration unit step, data No. unit step |
| Skip function | Via a CPU or an external command signal |
| Parameter initialization function | Provided |
| External input signal setting function | Via a CPU or a servo amplifier |
| Teaching function | Provided |
| Mark detection function | Continuous detection mode, specified number of detections mode, ring buffer mode |
| Mark detection function / Mark detection signal | Signals for the number of axes of the connected servo amplifiers |
| Mark detection function / Mark detection setting | 16 settings |
| Optional data monitor function | Up to 4 points/axis |
| Functional safety | DI/O connection of the servo amplifier*4 |
| Digital oscilloscope function | Bit data: 16 channels, word data: 16 channels*5 |
| Automatic return | Provided |
| Servo amplifier connection method | CC-Link IE TSN |
| Maximum distance between stations [m] | CC-Link IE TSN: 100 |
| Mass [kg] ~81ac87 | 0.30 |
| Exterior dimensions [mm] | 90.0 (H) x 50.0 (W) x 83.0 (D) |
| Number of control axes #43 | Up to 8 axes |
| Number of connectable stations | Motion control stations: 8, standard stations: 16 |
| 24 V DC external current consumption [A] | 0.24 |
| Listed / Application | Motion module |
| Listed / Product Summary | Maximum number of control axes: 8 axes, CC-Link IE TSN connection, Positioning control, synchronous control, speed control, torque control |
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر
Mitsubishi Electric
اطلب عرض سعر