Mobile Generator | 25kVA / 20kW | Diesel | 2.2L
رقم القطعة: MDG25IF4
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: MDG25IF4
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
Mobile Generator | 25kVA / 20kW | Diesel | 2.2L
| Model | MDG25IF4 |
|---|---|
| Category | Mobile Generators |
| kW/kVA Prime | 20 |
| Engine | Isuzu® 4LE2T |
| Spec Sheet / POWER RATING SUMMARY / Standby Power Rating | 25 kW, 31 kVA, 60 Hz |
| Spec Sheet / POWER RATING SUMMARY / Prime Power Rating | 20 kW, 25 kVA, 60 Hz |
| Spec Sheet / ENGINE / General / Make (Model) | Isuzu (4LE2T) |
| Spec Sheet / ENGINE / Cooling System / Cooling System Type | Radiator |
| Spec Sheet / ENGINE / General / EPA Emissions Compliance | Tier 4 Final |
| Spec Sheet / ENGINE / Cooling System / Water Pump Type | Belt Driven |
| Spec Sheet / ENGINE / General / After Treatment System | DOC |
| Spec Sheet / ENGINE / Cooling System / Fan Type | Pusher |
| Spec Sheet / ENGINE / General / Type | In-Line |
| Spec Sheet / ENGINE / General / Compression Ratio | 17.6:1 |
| Spec Sheet / ENGINE / General / Intake Air Method | Turbocharged |
| Spec Sheet / ENGINE / Fuel System / Fuel Type | Ultra Low Sulfur Diesel |
| Spec Sheet / ENGINE / Fuel System / Fuel | EN 590 / ASTM D975 |
| Spec Sheet / ENGINE / Engine Governing / Governor | Electronic |
| Spec Sheet / ENGINE / Engine Governing / Frequency Regulation (Steady State) | ±2% |
| Spec Sheet / ENGINE / Fuel System / Fuel Inject Pump - Make (Model) | Denso (HP3) |
| Spec Sheet / ENGINE / Fuel System / Fuel Pump Type | Engine Gear Driven |
| Spec Sheet / ENGINE / Fuel System / Injector Type | Electronic |
| Spec Sheet / ENGINE / Fuel System / Engine Type | Direct Injection High Pressure Common Rail |
| Spec Sheet / ENGINE / Lubrication System / Oil Filter Type | Spin-On Cartridge, Full Flow |
| Spec Sheet / ENGINE / Engine Electrical System / Ground Polarity | Negative (-) |
| Spec Sheet / STANDARD ALTERNATOR / Make (Model) | Marathon Electric (282PSL1705) |
| Spec Sheet / STANDARD ALTERNATOR / Standard Excitation | Shunt |
| Spec Sheet / STANDARD ALTERNATOR / Bearings | Double Shielded, Prelubricated |
| Spec Sheet / STANDARD ALTERNATOR / Field Type | Rotating |
| Spec Sheet / STANDARD ALTERNATOR / Coupling | Direct Flexible Disc |
| Spec Sheet / STANDARD ALTERNATOR / Insulation Class - Rotor | Class H |
| Spec Sheet / STANDARD ALTERNATOR / Prototype Short Circuit Test | Yes |
| Spec Sheet / STANDARD ALTERNATOR / Voltage Regulator Type | AVR |
| Spec Sheet / STANDARD ALTERNATOR / Quantity of Sensed Phases | 1 |
| Spec Sheet / STANDARD ALTERNATOR / Regulation Accuracy (Steady State) | ±0.5% |
| Spec Sheet / SUPERSTART ALTERNATOR / Make (Model) | Marathon Electric (283PSL1707) |
| Spec Sheet / SUPERSTART ALTERNATOR / Standard Excitation | Shunt |
| Spec Sheet / SUPERSTART ALTERNATOR / Bearings | Double Shielded, Prelubricated |
| Spec Sheet / SUPERSTART ALTERNATOR / Field Type | Rotating |
| Spec Sheet / SUPERSTART ALTERNATOR / Coupling | Direct Flexible Disc |
| Spec Sheet / SUPERSTART ALTERNATOR / Insulation Class - Rotor | H |
| Spec Sheet / SUPERSTART ALTERNATOR / Prototype Short Circuit Test | Yes |
| Spec Sheet / SUPERSTART ALTERNATOR / Voltage Regulator Type | AVR |
| Spec Sheet / SUPERSTART ALTERNATOR / Quantity of Sensed Phases | 1 |
| Spec Sheet / SUPERSTART ALTERNATOR / Regulation Accuracy (Steady State) | ±0.5% |
| Spec Sheet / VFLEX ALTERNATOR / Make (Model) | Marathon Electric (283PSL28106) |
| Spec Sheet / VFLEX ALTERNATOR / Standard Excitation | Shunt |
| Spec Sheet / VFLEX ALTERNATOR / Bearings | Double Shielded, Prelubricated |
| Spec Sheet / VFLEX ALTERNATOR / Field Type | Rotating |
| Spec Sheet / VFLEX ALTERNATOR / Coupling | Direct Flexible Disc |
| Spec Sheet / VFLEX ALTERNATOR / Insulation Class - Rotor | H |
| Spec Sheet / VFLEX ALTERNATOR / Prototype Short Circuit Test | Yes |
| Spec Sheet / VFLEX ALTERNATOR / Voltage Regulator Type | AVR |
| Spec Sheet / VFLEX ALTERNATOR / Quantity of Sensed Phases | 1 |
| Spec Sheet / VFLEX ALTERNATOR / Regulation Accuracy (Steady State) | ±0.5% |
| Spec Sheet / POWER RATINGS / 1-phase, 120/240 VAC @ 1.0 pf-zig zag / Standard Alternator Standby: kW | 17.5/17.5 (73) |
| Spec Sheet / POWER RATINGS / 1-phase, 120/240 VAC @ 1.0 pf-zig zag / Standard Alternator Prime: kW/k | 17.5/17.5 (73) |
| Spec Sheet / POWER RATINGS / 1-phase, 120/240 VAC @ 1.0 pf-zig zag / SUPERSTART Alternator Standby: | 17.5/17.5 (73) |
| Spec Sheet / POWER RATINGS / 1-phase, 120/240 VAC @ 1.0 pf-zig zag / SUPERSTART Alternator Prime: kW | 17.5/17.5 (73) |
| Spec Sheet / POWER RATINGS / 1-phase, 120/240 VAC @ 1.0 pf-zig zag / VFLEX Alternator Standby: kW/kV | 11/11 (46) |
| Spec Sheet / POWER RATINGS / 1-phase, 120/240 VAC @ 1.0 pf-zig zag / VFLEX Alternator Prime: kW/kVA | 11/11 (46) |
| Spec Sheet / POWER RATINGS / 3-phase, 208/120 VAC @ 0.8 pf-low wye / Standard Alternator Standby: kW | 25/31 (86) |
| Spec Sheet / POWER RATINGS / 3-phase, 208/120 VAC @ 0.8 pf-low wye / Standard Alternator Prime: kW/k | 20/25 (70) |
| Spec Sheet / POWER RATINGS / 3-phase, 208/120 VAC @ 0.8 pf-low wye / SUPERSTART Alternator Standby: | 25/31 (86) |
| Spec Sheet / POWER RATINGS / 3-phase, 208/120 VAC @ 0.8 pf-low wye / SUPERSTART Alternator Prime: kW | 20/25 (70) |
| Spec Sheet / POWER RATINGS / 3-phase, 208/120 VAC @ 0.8 pf-low wye / VFLEX Alternator Standby: kW/kV | 24/30 (83) |
| Spec Sheet / POWER RATINGS / 3-phase, 208/120 VAC @ 0.8 pf-low wye / VFLEX Alternator Prime: kW/kVA | 19/24 (66) |
| Spec Sheet / POWER RATINGS / 3-phase, 240/120 VAC @ 0.8 pf-delta / Standard Alternator Standby: kW/k | 25/31 (75) |
| Spec Sheet / POWER RATINGS / 3-phase, 240/120 VAC @ 0.8 pf-delta / Standard Alternator Prime: kW/kVA | 20/25 (60) |
| Spec Sheet / POWER RATINGS / 3-phase, 240/120 VAC @ 0.8 pf-delta / SUPERSTART Alternator Standby: kW | 25/31 (75) |
| Spec Sheet / POWER RATINGS / 3-phase, 240/120 VAC @ 0.8 pf-delta / SUPERSTART Alternator Prime: kW/k | 20/25 (60) |
| Spec Sheet / POWER RATINGS / 3-phase, 240/120 VAC @ 0.8 pf-delta / VFLEX Alternator Standby: kW/kVA | 24/30 (72) |
| Spec Sheet / POWER RATINGS / 3-phase, 240/120 VAC @ 0.8 pf-delta / VFLEX Alternator Prime: kW/kVA (A | 19/24 (57) |
| Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / Standard Alternator Standby: k | 25/31 (37) |
| Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / Standard Alternator Prime: kW/ | 20/25 (30) |
| Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / SUPERSTART Alternator Standby: | 25/31 (37) |
| Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / SUPERSTART Alternator Prime: k | 20/25 (30) |
| Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / VFLEX Alternator Standby: kW/k | 26/32 (36) |
| Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / VFLEX Alternator Prime: kW/kVA | 21/26 (32) |
| Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / Standard Alternator Standby: k | N/A |
| Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / Standard Alternator Prime: kW/ | N/A |
| Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / SUPERSTART Alternator Standby: | N/A |
| Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / SUPERSTART Alternator Prime: k | N/A |
| Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / VFLEX Alternator Standby: kW/k | 26/32 (29) |
| Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / VFLEX Alternator Prime: kW/kVA | 21/26 (25) |
| Alternator | Marathon Electric (282PSL1705) |
| Standby Power | 25 kW, 31 kVA, 60 Hz |
| Spec Sheet / ENGINE / Lubrication System / Oil Pump Type | Gear Driven |
| Spec Sheet / ENGINE / General / Bore - in (mm) | 3.35 (85) |
| Spec Sheet / ENGINE / Cooling System / Cooling System Capacity - qt (L) | 17.6 (16.6) |
| Spec Sheet / ENGINE / General / Stroke - in (mm) | 3.78 (96) |
| Spec Sheet / ENGINE / General / Cylinders - Qty | 4 |
| Spec Sheet / ENGINE / Cooling System / Fan Speed - rpm | 2,016 |
| Spec Sheet / ENGINE / Cooling System / Fan Diameter - in (cm) | 15.75 (40) |
| Spec Sheet / ENGINE / General / Displacement - in 3 (L) | 134 (2.2) |
| Spec Sheet / ENGINE / Fuel System / Fuel Filtering - μ | Primary: 10 |
| Spec Sheet / ENGINE / Fuel System / Fuel Supply Line Diameter- in (mm) | 0.375 (9.5) |
| Spec Sheet / ENGINE / Fuel System / Fuel Return Line Diameter- in (mm) | 0.375 (9.5) |
| Spec Sheet / ENGINE / Lubrication System / Crankcase Capacity - qt (L) | 10.9 (10.4) |
| Spec Sheet / ENGINE / Engine Electrical System / System Voltage - VDC | 12 |
| Spec Sheet / ENGINE / Engine Electrical System / Battery Charger Alternator - VDC (A) | 12 (50) |
| Spec Sheet / ENGINE / Engine Electrical System / Battery Size - CCA | 720 |
| Spec Sheet / ENGINE / Engine Electrical System / Battery Voltage (Battery Qty) | 12 (1) |
| Spec Sheet / STANDARD ALTERNATOR / Poles - Qty | 4 |
| Spec Sheet / STANDARD ALTERNATOR / Insulation Class - Stator | Class H |
| Spec Sheet / STANDARD ALTERNATOR / Total Harmonic Distortion | <5% |
| Spec Sheet / STANDARD ALTERNATOR / Telephone Interference Factor | <50 |
| Spec Sheet / SUPERSTART ALTERNATOR / Poles - Qty | 4 |
| Spec Sheet / SUPERSTART ALTERNATOR / Insulation Class - Stator | H |
| Spec Sheet / SUPERSTART ALTERNATOR / Total Harmonic Distortion | <5% |
| Spec Sheet / SUPERSTART ALTERNATOR / Telephone Interference Factor | <50 |
| Spec Sheet / VFLEX ALTERNATOR / Poles - Qty | 4 |
| Spec Sheet / VFLEX ALTERNATOR / Insulation Class - Stator | H |
| Spec Sheet / VFLEX ALTERNATOR / Total Harmonic Distortion | <5% |
| Spec Sheet / VFLEX ALTERNATOR / Telephone Interference Factor | <50 |