The Manual Call Point is used to manually initiate an alarm signal on the fire detection system. Suitable for weatherproof applications EN 54-11 & EN 54-17 Certified Reports an alarm in under 0.2 seconds ‘Plug and Play’ terminal connections for faster wiring Continuity link for wiring test before commissioning XP95 & Discovery compatible
| General / Warranty | 3 year |
|---|---|
| Mechanical / Product length | 27mm |
| Conformance / Approvals | CCS, DNV.GL, ESC, MED |
| Mechanical / Product width | 89mm |
| Mechanical / Product depth | 93mm |
| Mechanical / Product length (imperial) | 1.06in |
| Mechanical / Product width (imperial) | 3.5in |
| Mechanical / Product depth (imperial) | 3.66in |
| Mechanical / Colour | White |
| Mechanical / Materials housing | PolycarbonateABS |
| Environmental / Operating temperature (max) | 60°C |
| Environmental / Operating temperature (min) | -20°C |
| Environmental / Operating temperature | -20 to 60°C |
| Environmental / IP rating Value | IP67 |
| Environmental / Operating temperature (imperial) | -4 to 140°F |
| Environmental / Operating temperature (max) (imperial) | 140°F |
| Environmental / Operating temperature (min) (imperial) | -4°F |
| Environmental / Humidity (max) | 95%, RH |
| Environmental / Humidity (min) | 0%, RH |
| Environmental / Humidity Note | no condensation or icing |
| Electrical / Protocol voltage | 5 to 9V peak to peak |
| Environmental / Humidity | 0% to 95% (no condensation or icing) |
| Electrical / Protocol voltage (max) | 9V |
| Electrical / Protocol voltage (min) | 5V |
| Mechanical / Detection principle | Operation of a switch. |
| Electrical / Terminal functions L1 in | -L1 in, Loop (isolated) negative |
| Electrical / Terminal functions L2 | -L2, Line in & out negative |
| Electrical / Polarity | L1 &, L2 are polarity sensitive |
| Electrical / Power-up surge current | 1mA |
| Electrical / Quiescent current | 100μA |
| Electrical / Quiescent current tested at | 24V dc |
| Electrical / Maximum power-up time | 1 second |
| Performance / Analogue value nominal | 16 |
| Performance / Alarm level analogue value | 64 |
| Mechanical / Key type | KAC, Manal, Call, Point test & reset key |
| Apollo Part Number | 58100-976MAR |
| Apollo Range | xp95 |
| Apollo Category | mcp |
Apollo Fire Detectors
اطلب عرض سعر
Apollo Fire Detectors
اطلب عرض سعر
Apollo Fire Detectors
اطلب عرض سعر
Apollo Fire Detectors
اطلب عرض سعر
Apollo Fire Detectors
اطلب عرض سعر
Apollo Fire Detectors
اطلب عرض سعر
![Discovery Manual Call Point – Outdoor – Isolating [SIL2]](/_next/image?url=https%3A%2F%2Fmedia.zianly.com%2Fproducts%2F563428%2F1789801345192-a5fd5c30-8025-498b-8e8b-59cb372204e1__card.webp&w=3840&q=75)
Apollo Fire Detectors
اطلب عرض سعر
Apollo Fire Detectors
اطلب عرض سعر