Discovery Manual Call Point – Outdoor – Isolating [SIL2]
رقم القطعة: 58200-951SIL
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: 58200-951SIL
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
The Discovery Manual Call Point is used to manually initiate an alarm signal on the fire detection system. Suitable for weatherproof applications EN 54-11 & EN 54-17 Certified Resettable operating element 170° viewable LED XP95 & Discovery compatible
| General / Warranty | 3 year |
|---|---|
| Mechanical / Product length | 114mm |
| Conformance / Approvals | ESC |
| Mechanical / Product width | 114mm |
| Mechanical / Product depth | 74mm |
| Mechanical / Product length (imperial) | 4.49in |
| Mechanical / Weight | 325g |
| Mechanical / Product width (imperial) | 4.49in |
| Mechanical / Product depth (imperial) | 2.91in |
| Mechanical / Colour | Red |
| Mechanical / Materials housing | Polycarbonate |
| Environmental / Operating temperature (max) | 70°C |
| Environmental / Operating temperature (min) | 30°C |
| Environmental / Operating temperature | 30 to 70°C |
| Conformance / Standards | EN 54-11, EN 54-17 |
| Environmental / IP rating Value | IP67 |
| Environmental / Operating temperature (imperial) | 86 to 158°F |
| Environmental / Operating temperature (max) (imperial) | 158°F |
| Environmental / Operating temperature (min) (imperial) | 86°F |
| Environmental / Humidity (max) | 95%, RH |
| Environmental / Humidity (min) | 0%, RH |
| Environmental / Humidity Note | no condensation or icing |
| Electrical / Protocol voltage | 5 to 9V peak to peak |
| Environmental / Humidity | 0% to 95% (no condensation or icing) |
| Electrical / Protocol voltage (max) | 9V |
| Electrical / Protocol voltage (min) | 5V |
| Mechanical / Detection principle | Operation of a switch. |
| Electrical / Polarity | L1 &, L2 are polarity sensitive |
| Electrical / Power-up surge current | 1mA |
| Electrical / Quiescent current | 100μA |
| Electrical / Quiescent current tested at | 24V dc |
| Electrical / Maximum power-up time | 1 second |
| Mechanical / Key type | Apollo, Manal, Call, Point reset key |
| Apollo Part Number | 58200-951SIL |
| Apollo Range | xp95 |
| Apollo Category | mcp |