NZ2GNSS2-16DTE - DC input: 8 points (single wiring), 4 points (double wiring), 24 V DC, 7.3 mA,…
رقم القطعة: NZ2GNSS2-16DTE_3658
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: NZ2GNSS2-16DTE_3658
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
NZ2GNSS2-16DTE - DC input: 8 points (single wiring), 4 points (double wiring), 24 V DC, 7.3 mA,…
| Basic information / Model name | NZ2GNSS2-16DTE |
|---|---|
| Basic information / Overview | DC input: 8 points (single wiring), 4 points (double wiring), 24 V DC, 7.3 mA, response time: 1...70 ms, 8 points/common, negative common type, spring-clamp terminal block, transistor output: 8 points (single wiring), 4 points (double wiring), 24 V DC, 0.5 A/point, response time: 0.4 ms, 8 points/common, source + source type, spring-clamp terminal block |
| Basic information / Sales status | On sale |
| Listed / Series | Remote I/O |
| Listed / Model name | NZ2GNSS2-16DTE |
| Weight | 0.25 kg |
| Basic information / Conformance standard | UL cUL CE(EMC) CE(Machinery) CE(RoHS) IEC 61508 IEC 62061 EN ISO 13849-1 KC(EMC) LR NK DNV ABS |
| Shock resistance | Compliant with JIS B 3502 and IEC 61131-2 (147 m/s2, duration of action 11 ms, 3 times in X, Y, Z directions respectively by sine half-wave pulse) |
| Operating atmosphere | No corrosive gases, flammable gases, less conductive dust |
| Operating altitude | 0...2000 m |
| Installation location | Inside a control panel |
| Overvoltage category | II or less |
| Pollution degree | 2 or less |
| Insulation resistance | Between all DC external terminals and ground: 10 MΩ or higher by 500 V DC insulation resistance tester |
| Operating ambient temperature | 0...55 ˚C |
| Storage ambient temperature | -40...75 ˚C |
| Operating ambient humidity | 5...95 %RH, non-condensing |
| Storage ambient humidity | 5...95 %RH, non-condensing |
| Network topology | Line topology, star topology (Coexistence of line topology and star topology is possible.), and ring topology |
| Listed / Outline | DC input: 8 points (single wiring), 4 points (double wiring), 24 V DC, 7.3 mA, response time: 1...70 ms, 8 points/common, negative common type, spring-clamp terminal block, transistor output: 8 points (single wiring), 4 points (double wiring), 24 V DC, 0.5 A/point, response time: 0.4 ms, 8 points/common, source + source type, spring-clamp terminal block |
| Input type | DC input (negative common type) |
| Output type | Source + source type |
| Dielectric withstand voltage | Between all DC external terminals and ground: 510 V AC for 1 minute |
| External dimensions / Height | 50 mm |
| External dimensions / Width | 142 mm |
| External dimensions / Depth | 68 mm |
| Vibration resistance / Compliant with .. d IEC 61131-2 / Under intermittent vibration ~62dc24 | Frequency: 5...8.4 Hz, Half amplitude: 3.5 mm Frequency: 8.4...150 Hz, Constant acceleration: 9.8 m/s2 Sweep count: 10 times each in X, Y, Z directions |
| Vibration resistance / Compliant with .. and IEC 61131-2 / Under continuous vibration ~d68864 | Frequency: 5...8.4 Hz, Half amplitude: 1.75 mm Frequency: 8.4...150 Hz, Constant acceleration: 4.9 m/s2 |
| Equipment class | Class III |
| Listed / Large categories | Safety I/O |
| Listed / Medium categories | I/O |
| External interface | Communication part: RJ45 connector Module power supply part: Terminal block for module power supply and FG (two-piece spring clamp terminal block) I/O part, external power supply part: 40-point two-piece spring clamp terminal block (push-in) |
| CC-Link IE TSN Class | CC-Link IE TSN Class B CC-Link IE TSN Class A |
| Multicast filter | Available |
| Number of input points | 8 points (single wiring) 4 points (double wiring) |
| Rated input voltage | 24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC) |
| Rated input current | 7.3 mA TYP. (24 V DC) |
| Maximum number of simultaneous input points | 100 % |
| Station type | Remote station |
| ON voltage/ON current | 12 V DC or more/3 mA or more |
| OFF voltage/OFF current | 5 V DC or less/1.3 mA or less |
| Input resistance | 2.6 kΩ |
| Input common terminal arrangement | 8 points/common (spring clamp terminal block type) |
| Protection degree | IP2X |
| CC-Link IE TSN protocol version / CC-Link IE TSN Class B | Protocol version 2.0/1.0 |
| CC-Link IE TSN protocol version / CC-Link IE TSN Class A | Protocol version 2.0 |
| Maximum response time for time-managed polling / CC-Link IE TSN Class A | 512 µs |
| Cyclic transmission / RX/RY points | 16 points |
| Cyclic transmission / RWr/RWw points | 4 points |
| Module power supply / Voltage | 24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC) |
| Module power supply / Current | 170 mA |
| Listed / Small categories | DC input/transistor output |
| Number of output points | 8 points (single wiring), 4 points (double wiring) |
| Rated load voltage | 24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC) |
| Maximum load current | 0.5 A/point, 4 A/common |
| Maximum inrush current | 1.0 A, 10 ms or less |
| Leakage current at OFF | 0.1 mA or less |
| Maximum voltage drop at ON | 0.5 V DC (TYP.) 0.5 A, 0.8 V DC (MAX.) 0.5 A |
| Surge suppressor | Zener diode |
| Output common terminal arrangement | 8 points/common (spring clamp terminal block type) |
| Protection function | Output overload protection function |
| Input circuit response time / OFF to ON | 0.4 ms or less (24 V DC) |
| Output circuit response time / OFF to ON | 0.4 ms or less (24 V DC) |
| Input circuit response time / ON to OFF | 0.4 ms or less (24 V DC) |
| Output circuit response time / ON to OFF | 0.4 ms or less (24 V DC) |
| Safety remote station refresh response processing time | 2.0 ms |
| Input response time of safety remote station | Input circuit response time + Input response time (1.0 ms, 1.5 ms, 5 ms, 10 ms, 20 ms, 50 ms, 70 ms) |
| Output response time of safety remote station | Output circuit response time |
| External power supply for I/O part / Voltage | 24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC) |
| Cyclic transmission / SA\X/SA\Y points | 32 points |
| External power supply for I/O part / Current | 160 mA |
| Module power supply / Protection function | Module power supply overvoltage protection function, module power supply overcurrent protection function |
| External power supply for I/O part / Protection function | External power supply overvoltage protection function |
| Module power supply / Fuse | 1.6 A (not replaceable) |
| Power supply current for input device (COM+) | 0.4 A/terminal |