NZ2GNS12A2-14DT - DC input: 12 points (single wiring) 6 points (double wiring), 24 V DC, 6.8 mA,…
رقم القطعة: NZ2GNS12A2-14DT_3659
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
رقم القطعة: NZ2GNS12A2-14DT_3659
لا يعرض أي بائع سعرًا لهذا المنتج بعد.
للطلب والدفع استخدم تطبيق ENG.
NZ2GNS12A2-14DT - DC input: 12 points (single wiring) 6 points (double wiring), 24 V DC, 6.8 mA,…
| Basic information / Model name | NZ2GNS12A2-14DT |
|---|---|
| Basic information / Overview | DC input: 12 points (single wiring) 6 points (double wiring), 24 V DC, 6.8 mA, response time: 1...70 ms, 12 points/common, negative common, transistor output: single wiring is not possible, 2 points (double wiring), 24 V DC, 2 A/point, response time: 0.4 ms, 2 points/common, source + sink type, waterproof connector type |
| Basic information / Sales status | On sale |
| Listed / Series | Remote I/O |
| Listed / Model name | NZ2GNS12A2-14DT |
| Weight | 0.52 kg |
| Basic information / Conformance standard | UL cUL CE(EMC) CE(Machinery) CE(RoHS) IEC 61508 EN ISO 13849-1 KC(EMC) |
| Shock resistance | Compliant with JIS B 3502 and IEC 61131-2 (147 m/s2, 3 times each in 3 directions X, Y, Z) |
| Operating atmosphere | No corrosive gases, flammable gases, less conductive dust |
| Operating altitude | 0...2000 m |
| Installation location | Inside a control panel |
| Overvoltage category | II or less |
| Pollution degree | 2 or less |
| Insulation resistance | Between all DC external terminals and ground: 10 MΩ or higher by 500 V DC insulation resistance tester |
| Operating ambient temperature | 0...55 ˚C |
| Storage ambient temperature | -25...75 ˚C |
| Operating ambient humidity | Compliant with IP67 |
| Storage ambient humidity | 5...95 %RH, non-condensing |
| Network topology | Line topology, star topology (Coexistence of line topology and star topology is possible.), and ring topology |
| Listed / Outline | DC input: 12 points (single wiring) 6 points (double wiring), 24 V DC, 6.8 mA, response time: 1...70 ms, 12 points/common, negative common, transistor output: single wiring is not possible, 2 points (double wiring), 24 V DC, 2 A/point, response time: 0.4 ms, 2 points/common, source + sink type, waterproof connector type |
| Input type | DC input (negative common type) |
| Output type | Transistor output (source + sink type) |
| Dielectric withstand voltage | Between all DC external terminals and ground: 500 V AC for 1 minute |
| External dimensions / Height | 238 mm |
| External dimensions / Width | 63 mm |
| External dimensions / Depth | 49 mm |
| Vibration resistance / Compliant with .. d IEC 61131-2 / Under intermittent vibration ~62dc24 | Frequency: 5...8.4 Hz, Half amplitude: 3.5 mm Frequency: 8.4...150 Hz, Constant acceleration: 9.8 m/s2 Sweep count: 10 times each in X, Y, Z directions |
| Vibration resistance / Compliant with .. and IEC 61131-2 / Under continuous vibration ~d68864 | Frequency: 5...8.4 Hz, Half amplitude: 1.75 mm Frequency: 8.4...150 Hz, Constant acceleration: 4.9 m/s2 |
| Equipment class | Class III |
| Listed / Large categories | Safety I/O |
| Listed / Medium categories | I/O |
| External interface | Communication part: M12 waterproof connector, 8 pins, female, X-code Module power supply part: M12 waterproof connector, 5 pins, male, female, L-code I/O part: M12 waterproof connector, 5 pins, female, A-code |
| CC-Link IE TSN Class | CC-Link IE TSN Class B (factory default) CC-Link IE TSN Class A |
| Multicast filter | Available |
| Number of input points | 12 points (single wiring) 6 points (double wiring) |
| Rated input voltage | 24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC) |
| Rated input current | 6.8 mA TYP. (24 V DC) |
| Maximum number of simultaneous input points | 100 % |
| Station type | Remote station |
| ON voltage/ON current | 11 V DC or more/4 mA or more |
| OFF voltage/OFF current | 5 V DC or less/1.5 mA or less |
| Input resistance | 3.2 kΩ |
| Input common terminal arrangement | 12 points/common |
| Protection degree | IP67 |
| CC-Link IE TSN protocol version / CC-Link IE TSN Class B | CC-Link IE TSN Protocol version 1.0 CC-Link IE TSN Protocol version 2.0 |
| CC-Link IE TSN protocol version / CC-Link IE TSN Class A | CC-Link IE TSN Protocol version 2.0 |
| Maximum response time for time-managed polling / CC-Link IE TSN Class A | 512 µs |
| Cyclic transmission / RX/RY points | 16 points |
| Cyclic transmission / RWr/RWw points | 20 points |
| Module power supply / Voltage | 24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC) |
| Module power supply / Current | 260 mA |
| Listed / Small categories | DC input/transistor output |
| Number of output points | 2 points (double wiring) (single wiring not possible) |
| Rated load voltage | 24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC) |
| Maximum load current | 4 A/point (Y0+, Y0-), 2 A/point (Y1+, Y1-), 6 A/common |
| Maximum inrush current | Current is limited by the overload protection function. |
| Leakage current at OFF | 0.1 mA or less |
| Maximum voltage drop at ON | 1.0 V DC or less |
| Surge suppressor | Zener diode |
| Output common terminal arrangement | 2 points/common |
| Protection function | Limited current when detecting overcurrent: 4.4...5.2 A/point |
| Input circuit response time / OFF to ON | 0.4 ms or less (24 V DC) |
| Output circuit response time / OFF to ON | 0.4 ms or less (24 V DC) |
| Input circuit response time / ON to OFF | 0.4 ms or less (24 V DC) |
| Output circuit response time / ON to OFF | 0.4 ms or less (24 V DC) |
| Safety remote station refresh response processing time | Safety remote station safety cycle time + Communication path response time |
| Input response time of safety remote station | Input circuit response time + Input response time (1 ms, 1.5 ms, 5 ms, 10 ms (factory default), 20 ms, 50 ms, 70 ms) |
| Output response time of safety remote station | Output circuit response time |
| Cyclic transmission / SA\X/SA\Y points | SA\X: 32 points SA\Y: 32 points |
| Module power supply / Protection function | Module power supply overvoltage protection function, module power supply overcurrent protection function |
| Module power supply / Fuse | 1.6 A (not replaceable), 7 A (not replaceable) |
| Safety remote station safety cycle time | 2.0 ms |
| Communication path response time | 0.3 ms |
| Load power supply and external power supply for output part / Voltage | 24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC) |
| Load power supply and external power supply for output part / Current | 40 mA |
| Load power supply and external power supply for output part / Protection function | External power supply overvoltage protection function |
| Power supply current for input device | 0.4 A/terminal |