Mobile Generator | 570kVA / 456kW | Diesel | 18.1L

رقم القطعة: MDE570

لا يعرض أي بائع سعرًا لهذا المنتج بعد.

للطلب والدفع استخدم تطبيق ENG.

الوصف

Mobile Generator | 570kVA / 456kW | Diesel | 18.1L

المواصفات

ModelMDE570
CategoryMobile Generators
kW/kVA Prime456
EnginePerkins® 2806F-E18TAG1
Spec Sheet / POWER RATING SUMMARY / Standby Power Rating500 kW, 625 kVA, 60 Hz
Spec Sheet / POWER RATING SUMMARY / Prime Power Rating456 kW, 570 kVA, 60 Hz
Spec Sheet / ENGINE / General / Make (Model)Perkins (2806F-E18TAG1)
Spec Sheet / ENGINE / Cooling System / Cooling System TypeWater Cooled
Spec Sheet / ENGINE / General / EPA Emissions ComplianceTier 4 Final
Spec Sheet / ENGINE / Cooling System / Water Pump TypeEngine Gear Driven
Spec Sheet / ENGINE / Cooling System / Fan TypePusher
Spec Sheet / ENGINE / Cooling System / Fan Speed: RPMVariable Speed Clutch
Spec Sheet / ENGINE / General / TypeIn-Line
Spec Sheet / ENGINE / Cooling System / Fan Diameter: in (mm)46 (1,168)
Spec Sheet / ENGINE / General / Bore: in (mm)5.7 (145)
Spec Sheet / ENGINE / General / Stroke: in (mm)7.2 (183)
Spec Sheet / ENGINE / General / Compression Ratio16.0:1
Spec Sheet / ENGINE / General / Intake Air MethodTurbocharged & Aftercooled
Spec Sheet / ENGINE / Fuel System / Fuel TypeUltra Low Sulfur Diesel
Spec Sheet / ENGINE / Fuel System / FuelASTM D975 D2
Spec Sheet / ENGINE / Fuel System / Fuel FilteringPrimary: 10
Spec Sheet / ENGINE / Engine Governing / GovernorElectronic
Spec Sheet / ENGINE / Engine Governing / Frequency Regulation (Steady State)0.75%
Spec Sheet / ENGINE / Fuel System / Fuel Pump TypeEngine Gear Driven
Spec Sheet / ENGINE / Fuel System / Injector TypeElectronically Controlled Unit Injector
Spec Sheet / ENGINE / Lubrication System / Oil PumpGear
Spec Sheet / ENGINE / Lubrication System / Oil Filter TypeSpin-On Cartridge
Spec Sheet / ENGINE / Lubrication System / Engine Oil Capacity: qt (L)78.2 (74)
Spec Sheet / ENGINE / Engine Electrical System / System Voltage: VDC24
Spec Sheet / ENGINE / Engine Electrical System / Battery - CCA950
Spec Sheet / ENGINE / Engine Electrical System / Battery - V (Qty)12 (2)
Spec Sheet / ENGINE / Engine Electrical System / Ground PolarityNegative (-)
Spec Sheet / STANDARD ALTERNATOR / Make (Model)Leroy Somer (LSA 47.2 M7)
Spec Sheet / STANDARD ALTERNATOR / Standard ExcitationPMG
Spec Sheet / STANDARD ALTERNATOR / Poles4
Spec Sheet / STANDARD ALTERNATOR / Bearings1
Spec Sheet / STANDARD ALTERNATOR / Field TypeRevolving
Spec Sheet / STANDARD ALTERNATOR / Coupling14
Spec Sheet / STANDARD ALTERNATOR / Insulation Class - RotorClass H
Spec Sheet / STANDARD ALTERNATOR / Prototype Short Circuit TestYes
Spec Sheet / STANDARD ALTERNATOR / Voltage Regulator TypeDigital
Spec Sheet / STANDARD ALTERNATOR / Total Harmonic Distortion (THD)<2%
Spec Sheet / STANDARD ALTERNATOR / Quantity of Sensed Phases1
Spec Sheet / STANDARD ALTERNATOR / Telephone Interference Factor (TIF)<50
Spec Sheet / STANDARD ALTERNATOR / Regulation Accuracy (Steady State)0.50%
Spec Sheet / SUPERSTART ALTERNATOR / Make (Model)Leroy Somer (LSA 47.2 M8)
Spec Sheet / SUPERSTART ALTERNATOR / Standard ExcitationPMG
Spec Sheet / SUPERSTART ALTERNATOR / Poles4
Spec Sheet / SUPERSTART ALTERNATOR / Bearings1
Spec Sheet / SUPERSTART ALTERNATOR / Field TypeRevolving
Spec Sheet / SUPERSTART ALTERNATOR / Coupling14
Spec Sheet / SUPERSTART ALTERNATOR / Insulation Class - RotorClass H
Spec Sheet / SUPERSTART ALTERNATOR / Prototype Short Circuit TestYes
Spec Sheet / SUPERSTART ALTERNATOR / Voltage Regulator TypeDigitial
Spec Sheet / SUPERSTART ALTERNATOR / Total Harmonic Distortion (THD)<2%
Spec Sheet / SUPERSTART ALTERNATOR / Quantity of Sensed Phases1
Spec Sheet / SUPERSTART ALTERNATOR / Telephone Interference Factor (TIF)<50
Spec Sheet / SUPERSTART ALTERNATOR / Regulation Accuracy (Steady State)0.50%
Spec Sheet / VFLEX ALTERNATOR / Make (Model)Leroy Somer (LSA 47.2 L9)
Spec Sheet / VFLEX ALTERNATOR / Standard ExcitationPMG
Spec Sheet / VFLEX ALTERNATOR / Bearings1
Spec Sheet / VFLEX ALTERNATOR / Field TypeRevolving
Spec Sheet / VFLEX ALTERNATOR / Coupling14
Spec Sheet / VFLEX ALTERNATOR / Prototype Short Circuit TestYes
Spec Sheet / VFLEX ALTERNATOR / Voltage Regulator TypeDigital
Spec Sheet / VFLEX ALTERNATOR / Total Harmonic Distortion (THD)<2%
Spec Sheet / VFLEX ALTERNATOR / Quantity of Sensed Phases1
Spec Sheet / VFLEX ALTERNATOR / Telephone Interference Factor (TIF)<50
Spec Sheet / VFLEX ALTERNATOR / Regulation Accuracy (Steady State)0.50%
Spec Sheet / POWER RATINGS / 3-phase, 208/120 VAC @ 0.8 pf-low wye / Standard Alternator Standby: kW460/575 (1,598) 456/570 (1,584) 460/575 (1,598) 456/570 (1,584) 460/575 (1,598)
Spec Sheet / POWER RATINGS / 3-phase, 208/120 VAC @ 0.8 pf-low wye / VFLEX Alternator Prime: kW/kVA 456/570 (1,584)
Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / Standard Alternator Standby: k500/625 (753)
Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / Standard Alternator Prime: kW/456/570 (686)
Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / SUPERSTART Alternator Standby:500/625 (753)
Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / SUPERSTART Alternator Prime: k456/570 (686)
Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / VFLEX Alternator Standby: kW/k500/625 (753)
Spec Sheet / POWER RATINGS / 3-phase, 480/277 VAC @ 0.8 pf-high wye / VFLEX Alternator Prime: kW/kVA456/570 (686)
Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / Standard Alternator Standby: kN/A
Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / Standard Alternator Prime: kW/N/A
Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / SUPERSTART Alternator Standby:N/A
Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / SUPERSTART Alternator Prime: kN/A
Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / VFLEX Alternator Standby: kW/k500/625 (602)
Spec Sheet / POWER RATINGS / 3-phase, 600/346 VAC @ 0.8 pf-high wye / VFLEX Alternator Prime: kW/kVA456/570 (549)
Spec Sheet / DIMENSIONS AND WEIGHTS / Skid / Weight (Dry)17,482 (7,928)
Spec Sheet / DIMENSIONS AND WEIGHTS / Trailer / Weight (Dry)19,951 (9,048)
Spec Sheet / DIMENSIONS AND WEIGHTS / Skid / Dimensions - L×W×H204.8 (5.2)×73.0 (1.9)×109.0 (2.8)
Spec Sheet / DIMENSIONS AND WEIGHTS / Trailer / Dimensions - L×W×H260.0 (6.6)×102.0 (2.6)×118.8 (3.0)
Spec Sheet / DIMENSIONS AND WEIGHTS / Skid / Weight (Operating)23,375 (10,600)
Spec Sheet / DIMENSIONS AND WEIGHTS / Trailer / Weight (Operating)25,844 (11,720)
AlternatorLeroy Somer (LSA 47.2 M7)
Standby Power500 kW, 625 kVA, 60 Hz
Spec Sheet / ENGINE / General / Displacement: in³ (L)1,104 (18.1)
Spec Sheet / ENGINE / Cooling System / Cooling System Capacity - qt (L)16.7 (63.2)
Spec Sheet / ENGINE / General / Cylinders - Qty6
Spec Sheet / VFLEX ALTERNATOR / Poles - Qty4
Spec Sheet / ENGINE / General / After-Treatment SystemEGR, DOC, SCR, & DPF
Spec Sheet / VFLEX ALTERNATOR / Insulation Class -RotorClass H
Spec Sheet / POWER RATINGS / 3-phase, 240/139 VAC @ 0.8 pf-low wye / Standard Alternator Standby: kW500/625 (1,505) 456/570 (1,372) 500/625 (1,505) 456/570 (1,372) 500/625 (1,505)
Spec Sheet / POWER RATINGS / 3-phase, 240/139 VAC @ 0.8 pf-low wye / VFLEX Alternator Prime: kW/kVA 456/570 (1,372)